Overview of the spectrometer, information symbols, and safety conventions
Overviewpp. 11-12
Initial setup guidance and first-use notes
Procedurepp. 13-16
Connecting power, power cord selection, and environmental requirements
Procedurep. 17
Procedure for safely shutting down the instrument
Procedurepp. 18-20
Diagnostic values and verification of instrument performance
Procedurepp. 21-22
Collecting sample and background spectra, interchanging accessories
Procedurepp. 23-52
Operation, cleaning, and background collection for each accessory type
Procedurepp. 53-60
Replacing windows and source, maintenance cautions and notes
Orderingpp. 61-62
List of spare parts and consumable items
Specp. 63
Instrument technical specifications
Warningpp. 64-66
Safety warnings and regulatory information
p. 19table, 5 rows
p. 61table, 15 rows
p. 17table, 5 rows
p. 21table, 10 rows
Table 2 Diagnostic values
Value
Optimal (green)
Marginal (yellow)
Critical (red)
Comment
Energy (center-burst)
28,000-15,000
>28,000 or <10000
> 30,000 or < 3000
Indicates the overall alignment and proper gain adjustment for the system.
Source
1.9 A
>2.2 A or <1.6 A
>2.4 A or <1.4 A
Indicates a problem with the infrared source control voltage, or that the source has burnt out. Both voltage and amperage are displayed; however, amperage provides a sufficient diagnostic.
Laser signal
15,000-3,000
>15,000 or <3,000
>17,000 or < 2,000
Can verify gross alignment errors even if the reflectance cap is not in place.
Detector temperature
38–42
<38 or >42
<36 or >44
Indicates a problem with the cooling circuitry or an ambient temperature over the specified range.
CPU temperature
10–75
>75
>80
Indicates the ambient temperature over the specified range.
When using the Diffuse Reflectance sampling accessory, the appropriate reflectance disk must be in place to make these measurements. The diffuse gold reference disk should be used with the Diffuse Reflectance sampling accessory. This disk is permanently mounted into Position 1 of the sampling tray.
Table 3 Spare parts
Part number
Description
G8043-67483
Replacement flat tip for ATR
G8043-67484
Replacement pellet tip for ATR
G8043-67405
Polystyrene film for ATR/Transmission sampling accessory
G8043-67406
Polystyrene film for TumblIR/DialPath sampling accessory
PIKE-162-5450
NIST traceable polystyrene from PIKE approximately 38 µm (for IQOQ)
925-0128
NIST traceable polystyrene from ICL approximately 35 µm (for IQOQ)
G8043-67400
Infrared source with purge fitting
G8043-67401
Desiccant with purge fitting
G8043-67402
KBr window with removal tool
G8043-67403
ZnSe window with removal tool
G8043-67003
Cary FTIR Swivel Diamond ATR Press
G8043-67004
Cary FTIR Swivel Ge-ZnSe Press
G8043-67012
Purge kit for engine and Transmission sampling accessory
430-0135
15VDC 2.66A Power Supply
430-0018
FTIR USB Cable
For service contracts, repairs and refurbishment services, contact Agilent.
Table 1 Power switch LED status
Status
LED-color
Action (% duty cycle)
System OFF
No LED illumination
N/A
System OFF
Red
100%
System startup
Red / green
Green 0.5 s on / red 0.5 s on
System ON
Green
100%
Firmware update
Red / green
Green blinks rapidly twice then red blinks rapidly twice
Analyzing samples
Раздел
Страница
Interchanging Sampling Accessories
22
Diamond ATR Sampling Accessory
23
ZnSe ATR Sampling Accessory
27
Germanium ATR Sampling Accessory
31
5 Bounce Zinc Selenide ATR Sampling Accessory
34
Transmission Sampling Accessory
36
10 and 45 Degree Specular Reflectance Sampling Accessories
39
TumblIR Sampling Accessory
42
DialPath Sampling Accessory
45
Diffuse Reflectance Sampling Accessory
49
Engineering Facts
14 facts · every claim linked to a page
Installation
The instrument must be allowed to reach room temperature before unpacking to prevent condensation on components.
Prevents condensation damage during initial setup and installation.
Source
“place the shipping case in a room-temperature environment and allow several hours for the contents of the container to reach the room ambient temperature”
Conformité
Shipping the instrument in anything other than the original container voids the warranty.
Determines how the unit must be returned or relocated to preserve warranty coverage.
Source
“Shipping the Cary 630 FTIR in packaging other than the original shipping container will void the warranty.”
Installation
The sampling accessory must be installed for the instrument to function properly.
Confirms the accessory is mandatory, not optional, for operation.
Source
“Attaching the sampling accessory or interface is necessary in order to ensure proper working order of the Cary 630 FTIR.”
Installation
Power cords must be routed away from walkways to avoid strain damage to connectors.
Guides cable routing during installation to prevent apparatus or adapter damage.
Source
“All cords must be kept away from high traffic areas.”
Operation
Leaving the spectrometer powered on is recommended to keep moisture out.
Affects daily operating practice and desiccant/humidity management.
Source
“To help keep moisture out of the Cary 630 FTIR, it is recommended to leave the spectrometer on, even when not in use.”
Operation
The power button must be held for two seconds to switch the system on or off.
Prevents confusion about momentary-switch behavior during operation.
Source
“In order to turn the system on or off, hold down the button for two (2) seconds.”
Performance
A background spectrum should be collected before every sample to avoid environmental drift effects.
Sets the measurement workflow needed for accurate results.
Source
“it is recommended that the system is configured in the software to collect a background spectrum before every sample is analyzed”
Selection
The diamond ATR accepts samples across the full pH range 1 to 14.
Determines accessory choice for strong acids or abrasive samples.
Source
“it can accept samples with a pH range from 1 to 14”
Selection
The ZnSe ATR is limited to samples with pH between 5 and 9 and must not be used with hard or abrasive samples.
Prevents crystal damage and guides accessory selection by sample chemistry.
Source
“Only measure samples with a pH between 5 and 9.”
Selection
The Ge ATR provides shallower penetration, making it suited to highly absorbing carbon-black samples.
Guides accessory selection for highly absorbing or carbon-black-containing samples.
Source
“This is important when measuring samples containing carbon black, such as tires, rubbers and o-rings”
Maintenance
The desiccant should be replaced once humidity reaches 30% or the indicator turns pink.
Defines the maintenance trigger for desiccant replacement to protect optics.
Source
“Changing the desiccant is recommended once the humidity level has reached 30% or the color indicator is pink.”
Maintenance
After opening the unit, allow 30 minutes to 2 hours for warm-up and equilibration before use.
Sets the waiting period after service before reliable measurements.
Source
“can take 30 minutes to 2 hours”
Maintenance
The infrared source has a typical lifetime of three years and may need replacement.
Informs spare-part planning and expected service intervals.
Source
“The typical lifetime of the infrared source is three years.”
Safety
The system is not intrinsically safe and must only be used in atmospheres tested for flammable materials.
Critical for site selection and hazardous-area compliance.
Source
“The Cary 630 FTIR systems are NOT intrinsically safe.”