Technical Data Sheet — 2BH1610 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Fiche technique 2BH1 610 : ventilateurs à canal latéral avec moteurs IE3, 3~ 50/60 Hz, IP55, classe d'isolation F, UL 1450 et CAN/CSA C22.2 No. 68-09 (certificat E225239). Couvre les tailles 1-5 avec les variantes de tension HK (190-210/380-420 V, 220-240/380-420 V), HQ (475-525/550-600 V, 380-420/660-725 V, 220-240/440-480 V) et les variantes NP 60 Hz.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated pressure | 2,50 kW p.2 ↗ | 2BH1610-0HK11, 50 Hz |
| Max. differential pressure | -170 mbar p.2 ↗ | 2BH1610-0HK11, 50 Hz |
| Sound pressure level | 69 dB(A) p.2 ↗ | 2BH1610-0HK11, 50 Hz |
| Weight | 48 kg p.2 ↗ | 2BH1610-0HK11 |
| Rated pressure | 3,45 kW p.2 ↗ | 2BH1610-1HK21, 50 Hz |
| Max. differential pressure | -270 mbar p.2 ↗ | 2BH1610-1HK21, 50 Hz |
| Sound pressure level | 75 dB(A) p.2 ↗ | 2BH1610-1HK21, 50 Hz |
| Weight | 58 kg p.2 ↗ | 2BH1610-1HK21 |
| Rated pressure | 4,6 kW p.2 ↗ | 2BH1610-1HK31, 50 Hz |
| Max. differential pressure | -400 mbar p.2 ↗ | 2BH1610-1HK31, 50 Hz |
| Sound pressure level | 67 dB(A) p.2 ↗ | 2BH1610-1HK31, 50 Hz |
| Weight | 65 kg p.2 ↗ | 2BH1610-1HK31 |
| Rated pressure | 6,3 kW p.2 ↗ | 2BH1610-1HK41, 50 Hz |
| Max. differential pressure | -420 mbar p.2 ↗ | 2BH1610-1HK41, 50 Hz |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH1610-1HK41, 50 Hz |
| Weight | 73 kg p.2 ↗ | 2BH1610-1HK41 |
| Rated pressure | 8,6 kW p.2 ↗ | 2BH1610-1HK51, 50 Hz |
| Max. differential pressure | -420 mbar p.2 ↗ | 2BH1610-1HK51, 50 Hz |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH1610-1HK51, 50 Hz |
| Weight | 85 kg p.2 ↗ | 2BH1610-1HK51 |
| Rated pressure | 3,00 kW p.2 ↗ | 2BH1610-0HK11, 60 Hz |
| Max. differential pressure | -130 mbar p.2 ↗ | 2BH1610-0HK11, 60 Hz |
| Sound pressure level | 73 dB(A) p.2 ↗ | 2BH1610-0HK11, 60 Hz |
| Protection class | IP55 p.2 ↗ | |
| Insulation class | F p.2 ↗ |
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Protection class: IP55 p.2 ↗
- Insulation class: F p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-5 p.2 ↗ | 2BH1 | Series: side channel blower |
| 6-9 p.2 ↗ | 610 | Size 610 |
| 12-13 p.2 ↗ | HK/HQ | Voltage/frequency variant family |