Technical Data Sheet — 2BH1930 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 930: soplador de canal lateral con motores IE3, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 y CAN/CSA C22.2 No. 68-09 (certificado E225239). Abarca los tamaños de tipo 1-4 con varias variantes de tensión (190-210 V, 220-240/380-420 V, 475-525 V, 380-420/660-725 V) a 50 Hz y 60 Hz.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 190-210 V p.2 ↗ | 2BH1930-1AK01, size 1, 50 Hz, D connection |
| Rated current | 30,8 A p.2 ↗ | 2BH1930-1AK01, size 1, 50 Hz, D connection |
| Motor power | 8,6 kW p.2 ↗ | 2BH1930-1AK01, size 1, 50 Hz |
| Max. differential pressure (vacuum) | -120 mbar p.2 ↗ | 2BH1930-1AK01, size 1, 50 Hz |
| Max. differential pressure (pressure) | 110 mbar p.2 ↗ | 2BH1930-1AK01, size 1, 50 Hz |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH1930-1AK01, size 1, 50 Hz |
| Weight approx. | 212 kg p.2 ↗ | 2BH1930-1AK01, size 1, 50 Hz |
| Efficiency class | IE3 p.2 ↗ | 2BH1930-1AK01, size 1, 50 Hz |
| Rated voltage | 190-210 UU / 380-420 U V p.2 ↗ | 2BH1930-1AK01, size 1, 60 Hz |
| Rated current | 35,2 UU / 17,6 U A p.2 ↗ | 2BH1930-1AK01, size 1, 60 Hz |
| Motor power | 9,9 kW p.2 ↗ | 2BH1930-1AK01, size 1, 60 Hz |
| Max. differential pressure (vacuum) | -80 mbar p.2 ↗ | 2BH1930-1AK01, size 1, 60 Hz |
| Max. differential pressure (pressure) | 70 mbar p.2 ↗ | 2BH1930-1AK01, size 1, 60 Hz |
| Sound pressure level | 75 dB(A) p.2 ↗ | 2BH1930-1AK01, size 1, 60 Hz |
| Motor power | 12,6 kW p.2 ↗ | 2BH1930-1AK11, size 2, 50 Hz |
| Max. differential pressure (vacuum) | -210 mbar p.2 ↗ | 2BH1930-1AK11, size 2, 50 Hz |
| Max. differential pressure (pressure) | 200 mbar p.2 ↗ | 2BH1930-1AK11, size 2, 50 Hz |
| Motor power | 17,3 kW p.2 ↗ | 2BH1930-1AK21, size 3, 50 Hz |
| Max. differential pressure (vacuum) | -310 mbar p.2 ↗ | 2BH1930-1AK21, size 3, 50 Hz |
| Max. differential pressure (pressure) | 300 mbar p.2 ↗ | 2BH1930-1AK21, size 3, 50 Hz |
| Motor power | 21,3 kW p.2 ↗ | 2BH1930-1AK31, size 4, 50 Hz |
| Max. differential pressure (vacuum) | -320 mbar p.2 ↗ | 2BH1930-1AK31, size 4, 50 Hz |
| Max. differential pressure (pressure) | 370 mbar p.2 ↗ | 2BH1930-1AK31, size 4, 50 Hz |
| Weight approx. | 256 kg p.2 ↗ | 2BH1930-1AQ37, size 4, 50 Hz |
Operating Limits
- Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature for performance curves: 15 °C p.1 ↗
- Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-5 p.2 ↗ | 2BH19 | Series / type family (side channel blower 2BH1) |
| 6-7 p.2 ↗ | 30 | Size designation (2BH1 930) |
| 10-11 p.2 ↗ | AK / AQ | Voltage variant group: AK = 190-210 V / 220-240-380-420 V; AQ = 475-525 V / 380-420-660-725 V |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH1930-1AK01 p.2 ↗ | 2BH1930-1AK01 | 190-210 V, 50/60 Hz, size 1 | ||
| 2BH1930-1AK11 p.2 ↗ | 2BH1930-1AK11 | 190-210 V, 50/60 Hz, size 2 | ||
| 2BH1930-1AK21 p.2 ↗ | 2BH1930-1AK21 | 190-210 V, 50/60 Hz, size 3 | ||
| 2BH1930-1AK31 p.2 ↗ | 2BH1930-1AK31 | 190-210 V, 50/60 Hz, size 4 | ||
| 2BH1930-1AK06 p.2 ↗ | 2BH1930-1AK06 | 220-240/380-420 V, 50/60 Hz, size 1 | ||
| 2BH1930-1AK16 p.2 ↗ | 2BH1930-1AK16 | 220-240/380-420 V, 50/60 Hz, size 2 | ||
| 2BH1930-1AK26 p.2 ↗ | 2BH1930-1AK26 | 220-240/380-420 V, 50/60 Hz, size 3 | ||
| 2BH1930-1AK36 p.2 ↗ | 2BH1930-1AK36 | 220-240/380-420 V, 50/60 Hz, size 4 | ||
| 2BH1930-1AQ03 p.2 ↗ | 2BH1930-1AQ03 | 475-525 V, 50/60 Hz, size 1 | ||
| 2BH1930-1AQ13 p.2 ↗ | 2BH1930-1AQ13 | 475-525 V, 50/60 Hz, size 2 |