Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — 2BH721 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH7 210, soplador de canal lateral G-BH 7 N con motores IE3; cubre variantes de 50 Hz y 60 Hz con varios códigos de tensión (K1, K6, Q3, Q5, Q6, Q7) y números de pedido 2BH7210-0AK31-1, 2BH7210-0AK36-1, 2BH7210-0AQ33-1, 2BH7210-0AQ36-1, 2BH7210-0AQ37-1

Technical Data

Parameter Value Condition
Rated pressure (vacuum) -230 mbar p.2 ↗ 2BH7210, 50 Hz
Rated pressure (vacuum) -300 mbar p.2 ↗ 2BH7210, 60 Hz
Rated pressure (compressor) 290 mbar p.2 ↗ 2BH7210, 50 Hz
Rated pressure (compressor) 420 mbar p.2 ↗ 2BH7210, 60 Hz
Voltage 190-210 V p.2 ↗ 2BH7210-0AK31-1, 50 Hz, delta
Voltage 190-210 / 380-420 V p.2 ↗ 2BH7210-0AK31-1, 60 Hz, delta/Y
Voltage 220-240 / 380-420 V p.2 ↗ 2BH7210-0AK36-1, 50 Hz, delta/Y
Voltage 220-240 / 440-480 V p.2 ↗ 2BH7210-0AK36-1, 60 Hz, delta/Y
Voltage 500 V p.2 ↗ 2BH7210-0AQ33-1, 50 Hz, Y
Voltage 575 V p.2 ↗ 2BH7210-0AQ33-1, 60 Hz, Y
Voltage 380-420 / 660-725 V p.2 ↗ 2BH7210-0AQ37-1, 50 Hz, delta/Y
Voltage 440-480 V p.2 ↗ 2BH7210-0AQ37-1, 60 Hz, delta
Current 4,2 A p.2 ↗ 2BH7210-0AK31-1, 50 Hz
Current 4,8 A p.2 ↗ 2BH7210-0AK31-1, 60 Hz
Current 3,7 / 2,1 A p.2 ↗ 2BH7210-0AK36-1, 50 Hz, delta/Y
Current 4,2 / 2,1 A p.2 ↗ 2BH7210-0AK36-1, 60 Hz, delta/Y
Current 1,7 A p.2 ↗ 2BH7210-0AQ33-1, 50 Hz
Current 2,1 / 1,2 A p.2 ↗ 2BH7210-0AQ37-1, 50 Hz, delta/Y
Power 1,0 kW p.2 ↗ 2BH7210, 50 Hz
Power 1,1 kW p.2 ↗ 2BH7210, 60 Hz
Sound pressure level 59 dB(A) p.2 ↗ 2BH7210, 50 Hz
Sound pressure level 63 dB(A) p.2 ↗ 2BH7210, 60 Hz
Weight 21 kg p.2 ↗ 2BH7210
Protection category IP 55 p.1 ↗
Insulation class F p.1 ↗

Operating Limits

  • Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH7… Series / type designation (side channel blower, G-BH 7 N)
field 1 p.2 ↗ K / Q Voltage variant group (K = 190-240 V range, Q = 380-725 V range)
field 2 p.2 ↗ 1 / 6 / 3 / 5 / 7 Specific voltage/frequency code within the group
field 3 p.2 ↗ □ Placeholder for voltage code (K1, K6, Q3, Q5, Q6, Q7)
field 4 p.2 ↗ □ Placeholder for additional option (not further specified in document)
suffix p.2 ↗ -1 Design variant / revision

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH7210-0AK31-1 p.2 ↗ 2BH7210-0AK31-1 K1 50/60 Hz, 190-210 V Δ / 190-210 V YY / 220-240 V Δ / 380-420 V Y IE3 motor
2BH7210-0AK36-1 p.2 ↗ 2BH7210-0AK36-1 K6 50/60 Hz, 220-240 V Δ / 380-420 V Y; 60 Hz: 220-240 V YY / 440-480 V Y IE3 motor
2BH7210-0AQ33-1 p.2 ↗ 2BH7210-0AQ33-1 Q3 50/60 Hz, 500 V Y; 60 Hz: 575 V Y IE3 motor
2BH7210-0AQ36-1 p.2 ↗ 2BH7210-0AQ36-1 Q6 50/60 Hz, 220-240 V Δ / 380-420 V Y; 60 Hz: 440-480 V Y IE3 motor
2BH7210-0AQ37-1 p.2 ↗ 2BH7210-0AQ37-1 Q7 50/60 Hz, 380-420 V Δ / 660-725 V Y; 60 Hz: 440-480 V Δ / 460 V Δ IE3 motor