Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — G-BH7 2BH7510 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH7 510: soplador de canal lateral con convertidor de frecuencia integrado (IP55) para montaje en pared, tipo 2BH7510, funcionamiento a 50 Hz y 87 Hz (VFD), variantes de tensión 400 V y 345 V en delta, con opciones de pedido para ventilador accionado por separado (G17) y tamaños de convertidor de frecuencia A–K.

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH7510, 50 Hz
Rated voltage 400 V p.2 ↗ 2BH7510, 50 Hz
Rated current 9,8 A p.2 ↗ 2BH7510, 50 Hz
Rated motor power 5,0 kW p.2 ↗ 2BH7510, 50 Hz
Max. differential pressure vacuum -430 mbar p.2 ↗ 2BH7510, 50 Hz
Max. differential pressure pressure 440 mbar p.2 ↗ 2BH7510, 50 Hz
Sound pressure level 78 dB(A) p.2 ↗ 2BH7510, 50 Hz
Weight 43 kg p.2 ↗ 2BH7510, 50 Hz
Rated frequency 87 Hz p.2 ↗ 2BH7510, 87 Hz VFD
Rated voltage 345 D V p.2 ↗ 2BH7510, 87 Hz VFD, delta connection
Rated current 8,7 D A p.2 ↗ 2BH7510, 87 Hz VFD
Rated motor power 4,3 kW p.2 ↗ 2BH7510, 87 Hz VFD
Max. differential pressure vacuum -430 mbar p.2 ↗ 2BH7510, 87 Hz VFD
Max. differential pressure pressure 560 mbar p.2 ↗ 2BH7510, 87 Hz VFD
Sound pressure level 78 dB(A) p.2 ↗ 2BH7510, 87 Hz VFD
Weight 45 kg p.2 ↗ 2BH7510, 87 Hz VFD
Frequency converter rated mains voltage 400 V p.2 ↗ converter size E
Frequency converter max. motor current 13,0 A p.2 ↗ converter size E
Frequency converter typical motor power 5,5 kW p.2 ↗ converter size E
Frequency converter rated mains current 10,8 A p.2 ↗ converter size E
Frequency converter fuse protection 20 A p.2 ↗ converter size E
Frequency converter weight 3,9 kg p.2 ↗ converter size A

Operating Limits

  • Suction and ambient temperature for stated pressure differences: up to 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
  • Minimum mains voltage for frequency converters: 380 V p.1 ↗
  • Frequency converter protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH7510 Blower type/size designation
8-9 p.2 ↗ 0A Motor/voltage variant field
10-12 p.2 ↗ 321 / 351 / 326 / 356 / K16 / K26 / K56 Order option / motor variant code (e.g. K16, K26, K56 with separately driven fan option G17)
converter field 1 p.2 ↗ A–K Frequency converter size (A, B, C, D, E, F, G, H, J, K)
converter field 2-3 p.2 ↗ □ □ Placeholder for converter voltage/frequency variant

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH7510-0A321-1 p.2 ↗ 2BH7510-0A321-1 50 Hz, 400 V Standard blower
2BH7510-0A351-1 p.2 ↗ 2BH7510-0A351-1 87 Hz VFD, 345 V delta Standard blower
2BH7510-0A326-1 p.2 ↗ 2BH7510-0A326-1 50 Hz, 400 V Blower variant
2BH7510-0A356-1 p.2 ↗ 2BH7510-0A356-1 87 Hz VFD, 345 V delta Blower variant
2BH7510-0AK16-1 p.2 ↗ 2BH7510-0AK16-1 K16 with separately driven fan (order option G17) Order option G17
2BH7510-0AK26-1 p.2 ↗ 2BH7510-0AK26-1 K26 with separately driven fan (order option G17) Order option G17
2BH7510-0AK56-1 p.2 ↗ 2BH7510-0AK56-1 K56 with separately driven fan (order option G17) Order option G17
2FX16190ER00 p.2 ↗ 2FX16190ER00 Adaptor for wall mounting