Technical Data Sheet — 2BH751 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Fiche technique 2BH7 510, ventilateur à canal latéral G-BH 7 N avec moteurs IE3. Couvre les tailles 1 et 2 (variantes 33 kg / 38 kg), 50 Hz et 60 Hz, différentes variantes de tension (D, Y, YY, UU), versions de moteur IE3 et NP. Modèle de code de commande 2BH7…-..□.□-1.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 190-210 V p.2 ↗ | 2BH7510-0AK11-1, 50 Hz, D |
| Rated current | 6,9 A p.2 ↗ | 2BH7510-0AK11-1, 50 Hz, D |
| Motor power | 1,8 kW p.2 ↗ | 2BH7510-0AK11-1, 50 Hz |
| Vacuum | -310 mbar p.2 ↗ | 2BH7510-0AK11-1, 50 Hz |
| Pressure | 360 mbar p.2 ↗ | 2BH7510-0AK11-1, 50 Hz |
| Sound level | 62 dB(A) p.2 ↗ | 2BH7510-0AK11-1, 50 Hz |
| Weight | 33 kg p.2 ↗ | 2BH7510-0AK11-1 |
| Rated voltage | 190-210 UU / 380-420 U V p.2 ↗ | 2BH7510-0AK11-1, 60 Hz |
| Rated current | 7,8 UU / 3,9 U A p.2 ↗ | 2BH7510-0AK11-1, 60 Hz |
| Motor power | 2,0 kW p.2 ↗ | 2BH7510-0AK11-1, 60 Hz |
| Vacuum | -340 mbar p.2 ↗ | 2BH7510-0AK11-1, 60 Hz |
| Pressure | 330 mbar p.2 ↗ | 2BH7510-0AK11-1, 60 Hz |
| Sound level | 68 dB(A) p.2 ↗ | 2BH7510-0AK11-1, 60 Hz |
| Rated voltage | 190-210 V p.2 ↗ | 2BH7510-0AK21-1, 50 Hz, D |
| Rated current | 9,9 A p.2 ↗ | 2BH7510-0AK21-1, 50 Hz, D |
| Motor power | 2,5 kW p.2 ↗ | 2BH7510-0AK21-1, 50 Hz |
| Vacuum | -310 mbar p.2 ↗ | 2BH7510-0AK21-1, 50 Hz |
| Pressure | 420 mbar p.2 ↗ | 2BH7510-0AK21-1, 50 Hz |
| Sound level | 62 dB(A) p.2 ↗ | 2BH7510-0AK21-1, 50 Hz |
| Weight | 38 kg p.2 ↗ | 2BH7510-0AK21-1 |
| Rated voltage | 190-210 UU / 380-420 U V p.2 ↗ | 2BH7510-0AK21-1, 60 Hz |
| Rated current | 12,0 UU / 6,0 U A p.2 ↗ | 2BH7510-0AK21-1, 60 Hz |
| Motor power | 3,0 kW p.2 ↗ | 2BH7510-0AK21-1, 60 Hz |
| Vacuum | -370 mbar p.2 ↗ | 2BH7510-0AK21-1, 60 Hz |
| Pressure | 490 mbar p.2 ↗ | 2BH7510-0AK21-1, 60 Hz |
Operating Limits
- Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Reference air temperature for performance curves: 15 °C p.1 ↗
- Reference atmospheric pressure: 1013 mbar p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH7 | Series / type: side channel blower G-BH 7 N |
| 5-8 p.2 ↗ | 510 | Size designation (2BH7 510) |
| field 1 p.2 ↗ | 0 | Fixed digit |
| field 2 p.2 ↗ | A | Motor variant / voltage family (A, Q) |
| field 3 p.2 ↗ | K, Q | Voltage code: K = 190-210 V; Q = 220-240/380-420 V or 475-525/550-600 V |
| field 4 p.2 ↗ | 1, 2 | Size / power stage: 1 = 1,8 kW (33 kg), 2 = 2,5 kW (38 kg) |
| field 5 p.2 ↗ | 1, 3, 5, 6, 7 | Voltage / connection variant (e.g. 1 = 190-210 V, 3 = 475-525 V Y, 5 = 475-525 V D, 6 = 220-240 V D / 380-420 V Y, 7 = 400 V D / 690 V Y) |
| suffix p.2 ↗ | -1 | Design variant |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH7510-0AK11-1 p.2 ↗ | 2BH7510-0AK11-1 | 50/60 Hz, 190-210 V | Size 1, 1,8 kW (50 Hz) / 2,0 kW (60 Hz), 33 kg | |
| 2BH7510-0AK21-1 p.2 ↗ | 2BH7510-0AK21-1 | 50/60 Hz, 190-210 V | Size 2, 2,5 kW (50 Hz) / 3,0 kW (60 Hz), 38 kg | |
| 2BH7510-0AK16-1 p.2 ↗ | 2BH7510-0AK16-1 | 50/60 Hz, 220-240 V D / 380-420 V Y | Size 1, 1,8 kW (50 Hz) / 2,0 kW (60 Hz), 33 kg | |
| 2BH7510-0AK26-1 p.2 ↗ | 2BH7510-0AK26-1 | 50/60 Hz, 220-240 V D / 380-420 V Y | Size 2, 2,5 kW (50 Hz) / 3,0 kW (60 Hz), 38 kg | |
| 2BH7510-0AQ13-1 p.2 ↗ | 2BH7510-0AQ13-1 | 50/60 Hz, 500 V / 575 V | Size 1, 1,8 kW (50 Hz) / 2,0 kW (60 Hz), 33 kg | |
| 2BH7510-0AQ23-1 p.2 ↗ | 2BH7510-0AQ23-1 | 50/60 Hz, 500 V / 575 V | Size 2, 2,5 kW (50 Hz) / 3,0 kW (60 Hz), 38 kg | |
| 2BH7510-0AQ16-1 p.2 ↗ | 2BH7510-0AQ16-1 | 50/60 Hz | Size 1, 33 kg | |
| 2BH7510-0AQ26-1 p.2 ↗ | 2BH7510-0AQ26-1 | 50/60 Hz | Size 2, 38 kg | |
| 2BH7510-0AQ17-1 p.2 ↗ | 2BH7510-0AQ17-1 | 50/60 Hz, 380-420 V D / 460 V D | Size 1, 1,8 kW (50 Hz) / 2,0 kW (60 Hz), 33 kg | |