Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH7 520, soplador de canal lateral G-BH 7 N con motores IE3. Abarca los tamaños 1, 2, 3 con variantes de 50 Hz y 60 Hz, variantes de tensión 190-210 V, 220-240 V, 380-420 V, 440-480 V, 460 V, 500 V, 575 V, 690 V, y números de pedido 2BH7520-0AK21-1, 2BH7520-0AK51-1, 2BH7520-0AK71-1, 2BH7520-0AK26-1, 2BH7520-0AK56-1, 2BH7520-0AK76-1, 2BH7520-0AQ23-1, 2BH7520-0AQ53-1, 2BH7520-0AQ73-1, 2BH7520-0AQ26-1, 2BH7520-0AQ56-1, 2BH7520-0AQ76-1, 2BH7520-0AQ27-1, 2BH7520-0AQ57-1, 2BH7520-0AQ77-1.
Technical Data
| Parameter |
Value |
Condition |
| Rated pressure |
-490 mbar
p.2 ↗ |
size 1, 50 Hz, 190-210 V |
| Rated pressure |
-520 mbar
p.2 ↗ |
size 1, 60 Hz, 190-210/380-420 V |
| Rated pressure |
-500 mbar
p.2 ↗ |
size 2, 50 Hz, 190-210 V |
| Rated pressure |
-560 mbar
p.2 ↗ |
size 2, 60 Hz, 190-210/380-420 V |
| Rated pressure |
-500 mbar
p.2 ↗ |
size 3, 50 Hz, 190-210 V |
| Rated pressure |
-560 mbar
p.2 ↗ |
size 3, 60 Hz, 190-210/380-420 V |
| Voltage |
190-210 V
p.2 ↗ |
size 1, 50 Hz, delta |
| Voltage |
190-210 / 380-420 V
p.2 ↗ |
size 1, 60 Hz, delta / star |
| Voltage |
220-240 / 380-420 V
p.2 ↗ |
size 1, 50 Hz, delta / star |
| Voltage |
220-240 / 440-480 V
p.2 ↗ |
size 1, 60 Hz, delta / star |
| Voltage |
500 V
p.2 ↗ |
size 1, 50 Hz, star |
| Voltage |
575 V
p.2 ↗ |
size 1, 60 Hz, star |
| Voltage |
380-420 / 690 V
p.2 ↗ |
size 3, 50 Hz, delta / star |
| Voltage |
460 V
p.2 ↗ |
size 3, 60 Hz, delta |
| Current |
9,9 A
p.2 ↗ |
size 1, 50 Hz, 190-210 V delta |
| Current |
12,0 / 6,0 A
p.2 ↗ |
size 1, 60 Hz, 190-210/380-420 V |
| Current |
13,3 A
p.2 ↗ |
size 2, 50 Hz, 190-210 V |
| Current |
15,2 / 7,6 A
p.2 ↗ |
size 2, 60 Hz, 190-210/380-420 V |
| Current |
17,1 A
p.2 ↗ |
size 3, 50 Hz, 190-210 V |
| Current |
19,6 / 9,8 A
p.2 ↗ |
size 3, 60 Hz, 190-210/380-420 V |
| Power |
2,5 kW
p.2 ↗ |
size 1, 50 Hz |
| Power |
3,0 kW
p.2 ↗ |
size 1, 60 Hz |
| Power |
3,5 kW
p.2 ↗ |
size 2, 50 Hz |
| Power |
4,0 kW
p.2 ↗ |
size 2, 60 Hz |
| Power |
4,6 kW
p.2 ↗ |
size 3, 50 Hz |
Operating Limits
- Maximum suction and ambient temperature for stated total pressure differences: 25 °C
p.1 ↗
- Performance curve tolerance: ± 10 %
p.1 ↗
- Voltage tolerance for three phase motors: ± 10 %
p.2 ↗
- Frequency tolerance: ± 2 % maximum
p.2 ↗
- Protection category: IP 55
p.1 ↗
- Insulation class: F
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-6
p.2 ↗ |
2BH7520 |
Type designation: side channel blower 2BH7, size 520 |
| field 1
p.2 ↗ |
0 |
Fixed separator |
| field 2
p.2 ↗ |
A |
Motor variant / series code |
| field 3
p.3 ↗ |
K |
Voltage variant: 190-210 V (50 Hz) / 190-210 V or 380-420 V (60 Hz) |
| field 3
p.3 ↗ |
Q |
Voltage variant: 220-240 V or 380-420 V (50 Hz) / 440-480 V or 460 V (60 Hz) |
| field 4
p.2 ↗ |
2 |
Size 1 |
| field 4
p.2 ↗ |
5 |
Size 2 |
| field 4
p.2 ↗ |
7 |
Size 3 |
| field 5
p.3 ↗ |
1 |
50 Hz |
| field 5
p.3 ↗ |
6 |
60 Hz |
| field 6
p.2 ↗ |
1 |
Fixed suffix |
Ordering Data
| Ordering Code |
Part No. |
Variant / Code |
S'applique à |
Note |
| 2BH7520-0AK21-1
p.2 ↗ |
2BH7520-0AK21-1 |
|
size 1, 50 Hz, 190-210 V |
|
| 2BH7520-0AK51-1
p.2 ↗ |
2BH7520-0AK51-1 |
|
size 2, 50 Hz, 190-210 V |
|
| 2BH7520-0AK71-1
p.2 ↗ |
2BH7520-0AK71-1 |
|
size 3, 50 Hz, 190-210 V |
|
| 2BH7520-0AK26-1
p.2 ↗ |
2BH7520-0AK26-1 |
|
size 1, 50 Hz, 220-240/380-420 V |
|
| 2BH7520-0AK56-1
p.2 ↗ |
2BH7520-0AK56-1 |
|
size 2, 50 Hz, 220-240/380-420 V |
|
| 2BH7520-0AK76-1
p.2 ↗ |
2BH7520-0AK76-1 |
|
size 3, 50 Hz, 220-240/380-420 V |
|
| 2BH7520-0AQ23-1
p.2 ↗ |
2BH7520-0AQ23-1 |
|
size 1, 50 Hz, 500 V |
|
| 2BH7520-0AQ53-1
p.2 ↗ |
2BH7520-0AQ53-1 |
|
size 2, 50 Hz, 500 V |
|
| 2BH7520-0AQ73-1
p.2 ↗ |
2BH7520-0AQ73-1 |
|
size 3, 50 Hz, 500 V |
|
| 2BH7520-0AQ27-1
p.2 ↗ |
2BH7520-0AQ27-1 |
|
size 1, 50 Hz, 380-420/690 V |
|