Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH7620-0AK21-2
Voltage 190-210 D V p.2 ↗ 2BH7620-0AK21-2, 50 Hz
Current 13,3 D A p.2 ↗ 2BH7620-0AK21-2, 50 Hz
Power 3,5 kW p.2 ↗ 2BH7620-0AK21-2, 50 Hz
Vacuum -570 mbar p.2 ↗ 2BH7620-0AK21-2, 50 Hz
Pressure 480 mbar p.2 ↗ 2BH7620-0AK21-2, 50 Hz
Sound pressure level 68 dB(A) p.2 ↗ 2BH7620-0AK21-2, 50 Hz
Weight 59 kg p.2 ↗ 2BH7620-0AK21-2
Motor efficiency class IE3 p.2 ↗ 2BH7620-0AK21-2, 50 Hz
Rated frequency 60 Hz p.2 ↗ 2BH7620-0AK21-2
Voltage 190-210 / 380-420 V p.2 ↗ 2BH7620-0AK21-2, 60 Hz
Current 15,2 A p.2 ↗ 2BH7620-0AK21-2, 60 Hz
Power 4,0 kW p.2 ↗ 2BH7620-0AK21-2, 60 Hz
Vacuum -510 mbar p.2 ↗ 2BH7620-0AK21-2, 60 Hz
Pressure 420 mbar p.2 ↗ 2BH7620-0AK21-2, 60 Hz
Sound pressure level 72 dB(A) p.2 ↗ 2BH7620-0AK21-2, 60 Hz
Protection category IP 55 p.1 ↗ all motors
Insulation class F p.1 ↗ all motors
Voltage tolerance +/-10 % p.2 ↗ three phase motors
Frequency tolerance +/- 2 % p.2 ↗ maximum

Operating Limits

  • max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • voltage tolerance for three phase motors: +/-10 % p.2 ↗
  • frequency tolerance: +/- 2 % maximum p.2 ↗
  • protection category: IP 55 p.1 ↗
  • insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH762 Series and size designation (2BH7 620)
field 1 p.2 ↗ 0AK / 0AQ Motor/voltage variant family
field 2 p.2 ↗ 2 / 4 / 7 Performance size (1, 2, 3)
field 3 p.2 ↗ 1 / 3 / 6 Voltage code (e.g. 1 = 190-210 V, 3 = 500 V, 6 = 220-240/380-420 V)
field 4 p.2 ↗ 2 Frequency/variant suffix

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH7620-0AK21-2 p.2 ↗ 2BH7620-0AK21-2 50 Hz, 190-210 V D, IE3 size 1, 3.5 kW
2BH7620-0AK41-2 p.2 ↗ 2BH7620-0AK41-2 50 Hz, 190-210 V, IE3 size 2, 4.6 kW
2BH7620-0AK71-2 p.2 ↗ 2BH7620-0AK71-2 50 Hz, 190-210 V D, IE3 size 3, 6.3 kW
2BH7620-0AK26-2 p.2 ↗ 2BH7620-0AK26-2 50 Hz, 220-240 D / 380-420 U, IE3 size 1, 3.5 kW
2BH7620-0AK46-2 p.2 ↗ 2BH7620-0AK46-2 50 Hz, 220-240 D / 380-420 U, IE3 size 2, 4.6 kW
2BH7620-0AK76-2 p.2 ↗ 2BH7620-0AK76-2 50 Hz, 220-240 D / 380-420 U, IE3 size 3, 6.3 kW
2BH7620-0AQ23-2 p.2 ↗ 2BH7620-0AQ23-2 50 Hz, 500 V U, IE3 size 1, 3.5 kW
2BH7620-0AQ43-2 p.2 ↗ 2BH7620-0AQ43-2 50 Hz, 500 V U, IE3 size 2, 4.6 kW
2BH7620-0AQ27-2 p.2 ↗ 2BH7620-0AQ27-2 50 Hz, 380-420 D / 660-725 U, IE3 size 1, 3.5 kW
2BH7620-0AQ47-2 p.2 ↗ 2BH7620-0AQ47-2 50 Hz, 380-420 D / 660-725 U, IE3 size 2, 4.6 kW