Technical Data Sheet — G-BH7 2BH7620 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH7 620-0A: soplador de canal lateral con convertidor de frecuencia integrado (serie G-BH7 e). Cubre funcionamiento a 50 Hz y 60 Hz, conexiones de motor 400 V Δ / 380 V Y y tamaños de VFD A–K (2FC4xxx-1) con números de pedido de soplador correspondientes 2BH7620-0A…-2.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 100 Hz p.2 ↗ | 2BH7620-0A341-2 |
| Rated voltage | 400 V p.2 ↗ | 2BH7620-0A341-2, delta |
| Rated current | 16,2 A p.2 ↗ | 2BH7620-0A341-2 |
| Motor power | 8,8 kW p.2 ↗ | 2BH7620-0A341-2 |
| Max. differential pressure vacuum | -530 mbar p.2 ↗ | 2BH7620-0A341-2 |
| Max. differential pressure pressure | 390 mbar p.2 ↗ | 2BH7620-0A341-2 |
| Sound level | 79 dB(A) p.2 ↗ | 2BH7620-0A341-2 |
| Weight | 77 kg p.2 ↗ | 2BH7620-0A341-2 |
| Rated frequency | 100 Hz p.2 ↗ | 2BH7620-0A371-2 |
| Rated voltage | 400 V p.2 ↗ | 2BH7620-0A371-2, delta |
| Rated current | 22,0 A p.2 ↗ | 2BH7620-0A371-2 |
| Motor power | 12,1 kW p.2 ↗ | 2BH7620-0A371-2 |
| Max. differential pressure vacuum | -530 mbar p.2 ↗ | 2BH7620-0A371-2 |
| Max. differential pressure pressure | 630 mbar p.2 ↗ | 2BH7620-0A371-2 |
| Sound level | 85 dB(A) p.2 ↗ | 2BH7620-0A371-2 |
| Weight | 96 kg p.2 ↗ | 2BH7620-0A371-2 |
| Rated frequency | 87 Hz p.2 ↗ | 2BH7620-0A346-2 |
| Rated voltage | 380 V p.2 ↗ | 2BH7620-0A346-2, star |
| Rated current | 14,9 A p.2 ↗ | 2BH7620-0A346-2 |
| Motor power | 7,5 kW p.2 ↗ | 2BH7620-0A346-2 |
| Max. differential pressure vacuum | -570 mbar p.2 ↗ | 2BH7620-0A346-2 |
| Max. differential pressure pressure | 470 mbar p.2 ↗ | 2BH7620-0A346-2 |
| Sound level | 79 dB(A) p.2 ↗ | 2BH7620-0A346-2 |
| Weight | 75 kg p.2 ↗ | 2BH7620-0A346-2 |
| Rated frequency | 85 Hz p.2 ↗ | 2BH7620-0A376-2 |
Operating Limits
- Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
- Minimum mains voltage for frequency converters: 380 V p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH762 | Series and size (2BH7 side channel blower, size 620) |
| 7-9 p.2 ↗ | 0-0A | Design variant / housing version |
| 10-12 p.2 ↗ | 341 / 371 / 346 / 376 / K26 / K46 / K76 | Motor / winding variant code (determines power, voltage, frequency) |
| VFD field 1 p.2 ↗ | A / B / C / D / E / F / G / H / J / K | Frequency converter size (2FC4xxx-1) |
| VFD field 2 p.2 ↗ | □ | Placeholder for voltage / connection variant |
| VFD field 3 p.2 ↗ | □ | Placeholder for option variant |
| VFD field 4 p.2 ↗ | 00 | Fixed suffix |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH7620-0A341-2 p.2 ↗ | 2BH7620-0A341-2 | F | 100 Hz, 400 V Δ, 8.8 kW | VFD size F |
| 2BH7620-0A371-2 p.2 ↗ | 2BH7620-0A371-2 | G | 100 Hz, 400 V Δ, 12.1 kW | VFD size G |
| 2BH7620-0A346-2 p.2 ↗ | 2BH7620-0A346-2 | F | 87 Hz, 380 V Y, 7.5 kW | VFD size F |
| 2BH7620-0A376-2 p.2 ↗ | 2BH7620-0A376-2 | G | 85 Hz, 380 V Y, 10.2 kW | VFD size G |
| 2BH7620-0AK26-2 p.2 ↗ | 2BH7620-0AK26-2 | E | 87 Hz, 400 V Δ, 5.8 kW | VFD size E |
| 2BH7620-0AK46-2 p.2 ↗ | 2BH7620-0AK46-2 | F | 87 Hz, 400 V Δ, 7.5 kW | VFD size F |
| 2BH7620-0AK76-2 p.2 ↗ | 2BH7620-0AK76-2 | G | 85 Hz, 400 V Δ, 10.2 kW | VFD size G |