Technical Data Sheet — L-BL2 2BL2041 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Ficha técnica 2BL2 041: bomba de vacío de circuito compacta Elmo Rietschle L-BL2 ('Pump in a Box'), tamaño 2BL2041, 3~ 50/60 Hz, IP55, clase de aislamiento F. Códigos de pedido 2BL2041-2□K50-1B, -6B, -7B y 2BL2041-2□Q50-3B/-7B con variantes de tensión/frecuencia.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Pumping speed | 0-800 m³/h p.1 ↗ | 2BL2041, 50/60 Hz (curve range) |
| Inlet pressure | 0-800 mbar abs. p.1 ↗ | 2BL2041, performance curves |
| Power consumption at pump shaft | 0,0-1,5 kW p.1 ↗ | 2BL2041, 50/60 Hz (curve range) |
| Rated voltage | 190-210 ∆ V p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Rated voltage | 190-210 ΥΥ / 380-420 Υ V p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Rated current | 4,7 ∆ A p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Rated current | 5,40 ΥΥ / 2,70 Υ A p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Motor power | 0,85 kW p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Motor power | 1,15 kW p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Service factor | 1,29 - p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Service factor | 1,10 - p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Efficiency | IE3 - p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Sound pressure level | 65 dB(A) p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Sound pressure level | 69 dB(A) p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Weight | 40 kg p.2 ↗ | 2BL2041, 50 Hz, K50-1B |
| Rated voltage | 220-240 ∆ / 380-420 Υ V p.2 ↗ | 2BL2041, 50 Hz, K50-6B |
| Rated current | 4,5 ∆ / 2,6 Υ A p.2 ↗ | 2BL2041, 50 Hz, K50-6B |
| Rated voltage | 380-420 ∆ / 660-725 Υ V p.2 ↗ | 2BL2041, 50 Hz, Q50-7B |
| Rated current | 2,35 ∆ / 1,36 Υ A p.2 ↗ | 2BL2041, 50 Hz, Q50-7B |
| Rated voltage | 575 Υ V p.2 ↗ | 2BL2041, 60 Hz, K50-1B |
| Rated current | 1,58 Υ A p.2 ↗ | 2BL2041, 60 Hz, K50-1B |
| Motor power | 1,15 kW p.2 ↗ | 2BL2041, 60 Hz, K50-1B |
| Service factor | 1,04 - p.2 ↗ | 2BL2041, 60 Hz, K50-1B |
| Efficiency | NP - p.2 ↗ | 2BL2041, 60 Hz, K50-1B |
| Protection rating | IP55 - p.2 ↗ | 2BL2041, 3~ 50/60 Hz |
Operating Limits
- Protection rating: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
- Intake temperature for characteristic curves: 20 °C p.1 ↗
- Characteristic curve tolerance: ± 10 % p.1 ↗
- Sound pressure level tolerance: ±3 dB(A) p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BL2041 | Model range and size (L-BL2 compact circuit vacuum pump, size 041) |
| 8-9 p.2 ↗ | -2 | Design/variant index |
| 11-14 p.2 ↗ | K50 / Q50 | Voltage/frequency variant code: K50 for 50/60 Hz standard ranges, Q50 for 400 V∆/690 VY (50 Hz) and 460 V∆ (60 Hz) |
| 15-16 p.2 ↗ | 1B / 6B / 7B / 3B | Voltage range variant suffix (1B: 190-210 V; 6B: 220-240 V; 7B: 380-420 V; 3B: 500 V) |