Induztr
Résumé technique Visionneuse de documents Modèles associés

Fermentors Bioreactors Brochure Parallel Bioreactor Systems Microbiolo

Technical Reference Summary

Covered Models & Document Scope

Sistemas de biorreactor paralelo DASGIP para microbiología: sistemas de 4, 8, 16 y 24 unidades, con o sin Bioblock, en variantes estándar (MB) y SU; biorreactores de vidrio y de un solo uso; volúmenes de trabajo de 60–250 mL (vidrio) / 65–250 mL (un solo uso) para el sistema pequeño y de 200 mL–1.8 L (vidrio) / 250 mL–1.25 L (un solo uso) para el sistema mayor

Technical Data

Parameter Value Condition
Number of parallel bioreactors up to 24 p.3 ↗ DASbox Mini Bioreactor System
Number of parallel bioreactors up to 16 p.4 ↗ DASGIP Parallel Bioreactor System
Working volume 60 – 250 mL p.4 ↗ glass bioreactor
Working volume 65 – 250 mL p.4 ↗ single-use bioreactor
Working volume 200 mL – 1.8 L p.4 ↗ glass bioreactor
Working volume 250 mL – 1.25 L p.4 ↗ single-use bioreactor
Drive Overhead drive p.4 ↗
Impellers Rushton-type p.4 ↗
Agitation speed range 20 – 2,500 rpm p.4 ↗ glass bioreactor
Agitation speed range 20 – 2,000 rpm p.4 ↗ single-use bioreactor
Agitation speed range 100 – 1,600 rpm p.4 ↗ standard
Agitation speed range 30 – 1,250 rpm p.4 ↗ alternative
Temperature control Liquid-free heating and cooling (Peltier) p.4 ↗
Temperature control Integrated in the DASGIP Bioblock (optional) p.4 ↗ with Bioblock
Standard temperature 10 – 60 °C p.4 ↗ at 25 °C RT
Standard temperature 5 K above cooling agent temperature – 99 °C p.4 ↗ with Bioblock
Feeding lines per vessel 2 (standard)/4 (optional) p.4 ↗
Feeding lines per vessel Up to 8 p.4 ↗ larger system
Standard feed rates (depending on tube diameter) 0.3 – 9.5 mL/h to 13 – 420 mL/h p.4 ↗
Gas flow control TMFC p.4 ↗
Gas flow control TMFC/rotameter p.4 ↗ larger system
Standard gas mixing Air, N2, O2 and/or CO2 p.4 ↗
Standard gas flow rates 0.2 – 25 sL/h, 0.2 – 18 sL/h CO2 sL/h p.4 ↗
Standard gas flow rates 0.5 – 250 sL/h, 0.5 – 150 sL/h CO2 sL/h p.4 ↗ larger system
Software DASware control, other DASware optional p.4 ↗

Operating Limits

  • Standard temperature range: 10 – 60 °C at 25 °C RT p.4 ↗
  • Standard temperature range with Bioblock: 5 K above cooling agent temperature – 99 °C p.4 ↗
  • Maximum number of parallel bioreactors (DASbox): up to 24 p.3 ↗
  • Maximum number of parallel bioreactors (DASGIP): up to 16 p.4 ↗

Type Code Decoder

Position Token Meaning
1-2 p.4 ↗ 76 DASGIP system family prefix
3-4 p.4 ↗ DX / DG DX = system without Bioblock; DG = system with Bioblock
5-6 p.4 ↗ 04 / 08 / 16 / 24 number of parallel bioreactor positions (4-, 8-, 16- or 24-fold)
7-8 p.4 ↗ MB system variant
9-10 p.4 ↗ BB Bioblock included (only with DG prefix)
9-10 p.4 ↗ SU SU system variant

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
76DX04MB p.4 ↗ 76DX04MB 4-fold system system without Bioblock
76DX04MBSU p.4 ↗ 76DX04MBSU 4-fold system SU variant
76DX08MB p.4 ↗ 76DX08MB 8-fold system system without Bioblock
76DX08MBSU p.4 ↗ 76DX08MBSU 8-fold system SU variant
76DX16MB p.4 ↗ 76DX16MB 16-fold system system without Bioblock
76DX16MBSU p.4 ↗ 76DX16MBSU 16-fold system SU variant
76DX24MB p.4 ↗ 76DX24MB 24-fold system system without Bioblock
76DX24MBSU p.4 ↗ 76DX24MBSU 24-fold system SU variant
76DG04MBBB p.4 ↗ 76DG04MBBB 4-fold system with Bioblock Bioblock included
76DG04MBSU p.4 ↗ 76DG04MBSU 4-fold system with Bioblock SU variant