Top Supplies to Optimize Your LC Workflow

Sommaire

  1. Overview p. 2
    General recommendations for LC workflow supplies across systems
  2. Config. p. 3
    Workflow supplies recommendations for 1290 Infinity II and III LC systems
  3. Config. p. 5
    Workflow supplies recommendations for 1260 Infinity II and III Prime LC systems
  4. Config. p. 6
    Workflow supplies recommendations for 1260 Infinity II and III LC systems
  5. Config. p. 7
    Workflow supplies recommendations for 1220 Infinity II LC system
  6. p. 4 table, 6 rows
  7. p. 2 table, 22 rows
  8. p. 3 table, 11 rows
  9. p. 5 table, 5 rows
  10. p. 6 table, 8 rows
  11. p. 7 table, 3 rows

Part List for Kit

Part NumberDescriptionRecommended QuantityReason to UsePart List for KitProduct Family
G7167-68710InfinityLab Preventive Maintenance Kit for Multisampler (G7167B), Standard Configuration1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains needle assembly (G4267-87201), needle seat (G4267-87012) and injection valve rotor seal (5068-0198)PM Kit
G7167-68720InfinityLab Preventive Maintenance Kit for Multisampler (G7167B), Dual Needle Configuration1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains needle assembly (G4267-87201), 2 needle seats (G4267-87012), rotor seal valve DN (5068-0232) and rotor seal peripheral valve (5068-0229)PM Kit
5067-66161290 Infinity II and III Convenience Kit1Perfect starter kit for the 1290 Infinity II & III system, providing a carefully selected portfolio of InfinityLab supplies for efficient ramp up usage of new InfinityLab LC instrumentsThe kit contains solvent bottles (3 clear (9301-6524) and 1 amber (9301-6526)), 1 pack of silicone identification rings (2 each in 4 different colors) for solvent bottles (9301-6529), 1 pack of 100 removable stickers for solvent bottles (9301-6530), Stay Safe Caps Starter Kit (5043-1222), 4 packs of 100 certified vials clear (5182-0715), 1 pack of 100 certified vials amber (5182-0716), 5 packs of 100 bonded, pre-slit caps (5190-7023), 4 stainless steel solvent inlet filters (01018-60025), 1 InfinityLab Quick Change in-line filter assembly (5067-1603), 2 packs of 5 PTFE frits (01018-22707), 1 pack of 2 column holder clamps (G7116-68004), 1 pack of 2 column holder lamella clips (G7116-68003) and complete contents of 1290 Infinity II & III capillary kit (5067-6615)Starter Kit
5067-66151290 Infinity II and III Capillary Kit1Contain complete set of capillaries for system connections and performing system diagnostic tests, and Quick Connect and Quick Turn fittings for superior reliability and ease of useThe kit contains 1x spare set of system capillaries (0.17x300 mm (5067-6129), 0.17x900 mm (5500-1217), 0.12x500 mm (5500-1157), PTFE tubing 0.7x500 mm (5062-2462), PEEK fittings 10/pk (5065-4426)), 1x Quick Connect Assembly (5067-5957) and 2x Quick Turn fittings (5067-5966) including capillaries (0.12x120 mm (5500-1249), 0.12x280 mm (5500-1191)), blank nut (5067-6127), restriction capillary 0.12x200 mm (5022-2159), and union (5022-2184)Starter Kit
G7116-60051InfinityLab Quick Connect Heat Exchanger, High Flow (0.12 mm id, 3.0 μL Volume)1For high flow rate above ca. 2.5 mL/minConnection Supplies
5067-5963InfinityLab Quick Connect Heat Exchanger, Low Dispersion Kit (0.075 mm id, 1.1 μL Volume, with Connecting Capillaries)1Reduce sample dispersion to improve sensitivityConnection Supplies

* PM: Preventive Maintenance

General LC workflow supplies recommendations for Agilent InfinityLab 1220/1260/1290 series of HPLC instruments

Part NumberDescriptionRecommended QuantityReason to UsePart Family
5067-1603InfinityLab Quick Change inline filter assembly for UHPLC, with 2.1 mm id, 0.2 μm filter discs1Extend column lifetime, easy-to-use with finger-tight replacement, touchless packaging for easy replacement (Top Recommendation)Inline Filters
5067-1602InfinityLab Quick Change inline filter assembly for HPLC, with 4.6 mm id, 0.5 μm filter discs1Extend column lifetime, easy-to-use with finger-tight replacement, touchless packaging for easy replacement (Top Recommendation)Inline Filters
5067-1607InfinityLab Quick Change inline filter assembly for UHPLC with Quick Turn and rigid capillary, 2.1 mm, 0.2 μm filter discs1Extend column lifetime, easy-to-use with high-pressure, finger-tight replacement, ensures zero-dead-volume connection , touchless packaging for easy replacement (Top Recommendation)Inline Filters
5067-1606InfinityLab Quick Change inline filter assembly for HPLC with Quick Turn and rigid capillary, 4.6 mm, 0.5 μm filter discs1Extend column lifetime, easy-to-use with high-pressure, finger-tight replacement, ensures zero-dead-volume connection, touchless packaging for easy replacement (Top Recommendation)Inline Filters
5067-1621InfinityLab Quick Change Solvent Purifier assembly, 3.0 x 75 mm1Removes chemical solvent impurities from mobile phases (other dimensions available)Solvent Purifier
5067-5958InfinityLab Quick Connect fitting assembly including stainless steel capillary 0.12x150 mm, for 1290 Systems1For finger-tight connection onto column inlet, pressure stability up to 1300 bar, spring-loaded design to ensure zero-dead-volume (Top Recommendation)LC Capillaries and Fittings
5067-6167InfinityLab Quick Connect fitting assembly including stainless steel capillary 0.17x150 mm, for 1260 Systems1For finger-tight connection onto column inlet, pressure stability up to 1300 bar, spring-loaded design to ensure zero-dead-volume (Top Recommendation)LC Capillaries and Fittings
5067-5966InfinityLab Quick Turn fitting2For connections on column outlet and detector, finger-tight up to 600 bar, spring-loaded design to ensure zero-dead-volumeLC Capillaries and Fittings
5500-1191InfinityLab Quick Turn Capillary ST 0.12x280 mm1For connection between column outlet and detector, used with Quick Turn fitting (5067-5966)LC Capillaries and Fittings
5043-0915Mounting tool for InfinityLab Quick Turn fitting1Plastic tool to tighten Quick Turn fitting for high pressure up to 800 barLC Capillaries and Fittings
5043-1222InfinityLab Stay Safe Cap Kit including 4 caps, 4 venting valves, and 4 fittings1For stopping solvent vapor from solvent bottles leaching into the air. The GL45 thread allows to fix the Stay Safe caps to the Agilent solvent bottles (Top Recommendation)Solvent and Sample Containers
5043-1338InfinityLab Stay Safe Cap/Waste Can Kit, Stay Safe Cap S60 with 4 ports plus 10 L waste can1For safely collecting your system waste and prevent solvent vapor from leaching into the air, requires charcoal filter (5043-1193)Solvent and Sample Containers
5043-1221InfinityLab Stay Safe Cap/Waste Can Kit, Stay Safe Cap with 4 ports and Leak Hose Plus 6 L Waste Can1For safely collecting your system waste and prevent solvent vapor from leaching into the air, requires charcoal filter (5043-1193)Solvent and Sample Containers
5043-1193InfinityLab Charcoal Filter with Time Strip2Charcoal filter for absorbing the volatile compounds from Stay Safe Caps waste solution, with time strip to remind the user to replace it regularlySolvent and Sample Containers
5043-1339InfinityLab Stay Safe Purging Bottle1For easy and secure purging of up to four solvent channels, prevent solvent vapor from leaching into the air (Top Recommendation)Solvent and Sample Containers
9301-6526InfinityLab Solvent Bottle, GL45, Amber, 1 L1Amber glass bottle to mitigate photodegradation of sensitive solvents or buffersSolvent and Sample Containers
9301-6528InfinityLab Solvent Bottle, GL45, Clear, 1 L11 L clear glass bottleSolvent and Sample Containers
9301-6342InfinityLab Solvent Bottle, GL45, Clear, 2 L12 L clear glass bottleSolvent and Sample Containers
9301-6341InfinityLab Solvent Bottle, GL45, Amber, 2 L12 L amber glass bottleSolvent and Sample Containers
9301-6529InfinityLab Identification Silicone Rings, 8/pk1Color identification for solvent bottlesSolvent and Sample Containers
9301-6530Stickers, for InfinityLab solvent bottles, 100/pk1Removable stickers for easy label removal without any residue
5043-9310InfinityLab Well-plate 96/0.5 mL, 30/pk1In combination with the closing mat the plates have been tested on all Agilent autosamplersWell-plate

1290 Infinity II and III LC workflow supplies recommendations

Part NumberDescriptionRecommended QuantityReason to UseProduct Family
5042-1389InfinityLab Well-plate Closing Mat, 50/pk1In combination with the plates the closing mat have been tested on all Agilent autosamplersWell-plate
5191-6776InfinityLab Solvent Filtration Assembly, Including Glass Funnel, 250 mL, Membrane Holder Glass Base, Glass Flask, 1 L, and Aluminum Clamp1For preparing suitable mobile phases for HPLC and UHPLC. It can prevent small impurities in the solvent from clogging the system filter or LC column, causing excessive pressure, especially recommended for buffersLC Filtration
5191-4340InfinityLab Filter Membrane, Regenerated Cellulose 47 mm, Pore Size 0.2 μm, 100/pk1Most common membrane filters for 5191-6776LC Filtration
01018-60025Stainless Steel Solvent Inlet Filter, 10 μm4Smaller pore size than standard glass filter, recommended for buffers and LC/MSLC Filtration
5043-1759* 5043-1252**InfinityLab Flex Bench1For highest flexibility in the setup of Agilent LC instruments and to easily move the system everywhere in the lab (Top Recommendation)LC Bench
5043-1740* 5043-1711**InfinityLab Benchtop1For existing lab benches, improve flexibility in setup of Agilent LC instruments (Top Recommendation)LC Bench
G6015B* G6015A**InfinityLab Flex Bench MS1Allows you to keep your Agilent InfinityLab LC/MSD or Ultivo LC/MS systems in one stack with easy access to all areasLC Bench
5190-0917InfinityLab Long-life HiS Deuterium Lamp, with RFID Tag, for Diode Array Detector (G7117A/B/C)1Spare lamp for detector to avoid system downtimes if lamp is at the end of its lifeLC Lamps
G1314-60101InfinityLab Long-life HiS Deuterium Lamp, with RFID Tag, for Variable Wavelength Detectors (G7114A/B)1Spare lamp for detector to avoid system downtimes if lamp is at the end of its lifeLC Lamps
G7120-68741InfinityLab Preventive Maintenance Kit for High Speed Pump (G7120A)1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reduction The kit contains 4 pump seals (0905-1719), 2 sets of seal cap assembly (5067-4728), peristaltic pump (5065-4445), PTFE frits 5/pk (01018-22707), 2 gold seals for outlet valve (G4220-20020) and 4 seal washes (0905-1175)PM Kit
G7104-68741InfinityLab Preventive Maintenance Kit for Flexible Pump (G7104A)1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reduction The kit contains 2 pump seals (0905-1719), frit assembly (5067-5716), peristaltic pump (5065-4445), frits for 1290 inline filters 5/pk (5023-0271), gold seal for outlet valve (G4220-20020) and 2 seal wash (0905-1175)PM Kit

* with power strip, available except in Asia Pacific; ** without power strip, for Asia Pacific

1260 Infinity II and III Prime LC workflow supplies recommendations

Part NumberDescriptionRecommended QuantityReason to UsePart List for KitProduct Family
5190-0917InfinityLab Long-life HiS Deuterium Lamp, with RFID Tag, for Diode Array Detector (G7117A/B/C)1Spare lamp for detector to avoid system downtimes if lamp is at the end of its lifeLC Lamps
G1314-60101InfinityLab Long-life HiS Deuterium Lamp, with RFID Tag, for Variable Wavelength Detectors (G7114A/B)1Spare lamp for detector to avoid system downtimes if lamp is at the end of its lifeLC Lamps
G7104-68741InfinityLab Preventive Maintenance Kit for Flexible Pump (G7104A)1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains 2 pump seals (0905-1719), 2 seal wash seals (0905-1175), frit for outlet filter (5067-5417), peristaltic pump (5065-4445), frits for inline filter 5/pk (5023-0271), and gold seal for outlet valve (G4220-20020)PM Kit
G7129-68740InfinityLab Preventive Maintenance Kit Vialsampler (G7129C)1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains needle (G7129-87200), needle seat (G7129-87017), peristaltic pump (5065-4445), rotor seal (0101-1416) and finger caps 15/pk (5063-6506)PM Kit
G7167-68730InfinityLab Preventive Maintenance Kit Multisampler (G7167A)1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains needle (G4267-87201), needle seat (G4267-87012) and rotor seal (5068-0209)PM Kit

InfinityLab Long-life HiS Deuterium Lamp; 1260 Infinity III Prime LC Workflow

1260 Infinity II and III LC workflow supplies recommendations

Part NumberDescriptionRecommended QuantityReason to UsePart List for KitProduct Family
2140-0820InfinityLab Long-life Deuterium Lamp, with RFID Tag, for Diode Array and Multiple Wavelength Detectors (G7115A/G7165A)1Spare lamp for detector to avoid system downtimes if lamp is at the end of its lifeLC Lamps
G1314-60101InfinityLab Long-life HiS Deuterium Lamp, with RFID Tag, for Variable Wavelength Detectors (G7114A/B)1Spare lamp for detector to avoid system downtimes if lamp is at the end of its lifeLC Lamps
5067-66171260 Infinity II and III Convenience Kit1Perfect starter kit for the 1260 Infinity II & III system, providing a carefully selected portfolio of InfinityLab supplies for efficient ramp up usage of new InfinityLab LC instrumentsThe kit contains solvent bottles (3 clear (9301-6524) and 1 amber (9301-6526)), 1 pack of silicone identification rings (2 each in 4 different colors) for solvent bottles (9301-6529), 1 pack of 100 removable stickers for solvent bottles (9301-6530), Stay Safe Caps Starter Kit (5043-1222), 4 packs of 100 certified vials clear (5182-0715), 1 pack of 100 certified vials amber (5182-0716), 5 packs of 100 bonded, pre-slit caps (5190-7023), 4 stainless steel solvent inlet filters (01018-60025) , 1 InfinityLab Quick Change in-line filter assembly (5067-1603), 2 packs of 5 PTFE frits (01018-22707), 1 pack of 2 column holder clamps (G7116-68004), 1 pack of 2 column holder lamella clips (G7116-68003) and complete contents of 1260 Infinity II & III capillary kit (5067-6614)Starter Kit
5067-66141260 Infinity II and III Capillary Kit1Contain complete set of capillaries for system connections and performing system diagnostic tests, and Quick Connect and Quick Turn fittings for superior reliability and ease of useThe kit contains 1x spare set of system capillaries (0.17x500 mm (5500-1246), 0.17x900 mm (5500-1217), 0.12x500 mm (5500-1157), PTFE tubing 0.7x500 mm (5062-2462), PEEK fittings 10/pk (5065-4426)), 1x Quick Connect Assembly (5500-1181) and 2x Quick Turn fittings (5067-5966) including capillaries (0.17x120 mm (5500-1250), 0.12x280 mm (5500-1191)), blank nut (5043-0277), restriction capillary 0.12x200 mm (5022-2159), and union (5022-2184)Starter Kit
G1310-68741InfinityLab Preventive Maintenance Kit Isocratic and Quaternary Pump (G7110B, G7111A/B)1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains plunger seal (5063-6589), 2 sets of seal cap assembly (5067-4728), 2 film washers (01018-07102), and PTFE Frits 5/pk (01018-22707)PM Kit
G7129-68740InfinityLab Preventive Maintenance Kit Vialsampler (G7129C)1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains needle (G7129-87200), needle seat (G7129-87017), peristaltic pump (5065-4445), rotor seal (0101-1416) and finger caps 15/pk (5063-6506)PM Kit
G7167-68730InfinityLab Preventive Maintenance Kit Multisampler (G7167A)1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains needle (G4267-87201), needle seat (G4267-87012) and rotor seal (5068-0209)PM Kit
G7116-60061InfinityLab Quick Connect Heat Exchanger, High Flow (0.17 mm id, 6.0 μL volume)1For high flow rate above ca. 2.5 mL/minConnection Supplies

1220 Infinity II LC workflow supplies recommendations

Part NumberDescriptionRecommended QuantityReason to UsePart List for KitProduct Family
2140-0820InfinityLab Long-life Deuterium Lamp, with RFID Tag, for Diode Array and Multiple Wavelength Detector of 1220 Infinity II LC1Spare lamp for diode array detector to avoid system downtimes if lamp is at the end of its lifeLC Lamps
G1314-60101InfinityLab Long-life HiS Deuterium Lamp, with RFID Tag, for Variable Wavelength Detector of 1220 Infinity II LC1Spare lamp for variable wavelength detector to avoid system downtimes if lamp is at the end of its lifeLC Lamps
G4280-68730InfinityLab Preventive Maintenance Kit, for 1220 Infinity II system with Autosampler1Our study showed that conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reductionThe kit contains needle (G1313-87201), needle seat (G1329-87017), rotor seal (0100-1853), PTFE frits 5/pk (01018-22707), 2 sets of seal cap assembly (5067-4728) and plunger seals 2/pk (5063-6589)PM Kit

Engineering Facts

13 facts · every claim linked to a page
Selection

Quick Connect fittings are rated for pressure stability up to 1300 bar, so they suit both HPLC and UHPLC column inlet connections.

Confirms the fitting can be used on high-pressure UHPLC systems without risk of failure at the column inlet.

Source
“Reliable and reusable fittings—long lasting and reseal tightly, and are stable up to 1300 bar”
Installation

The spring-loaded Quick Connect design guarantees zero dead volume at the connection, which protects peak shape.

Zero-dead-volume connections are mandatory to avoid band broadening and carryover when installing column inlet fittings.

Source
“Spring-loaded design to ensure zero-dead-volume”
Selection

Inline filter assemblies are offered in two pore sizes matched to column ID: 0.2 µm for 2.1 mm UHPLC and 0.5 µm for 4.6 mm HPLC.

Choosing the wrong pore size or ID for the column format can cause extra pressure or insufficient particle protection.

Source
“InfinityLab Quick Change inline filter assembly for UHPLC, with 2.1 mm id, 0.2 μm filter discs”
Installation

Quick Turn fittings are finger-tight only up to 600 bar, and the plastic mounting tool is needed to reach 800 bar.

Installer must know that hand-tightening alone is insufficient above 600 bar and the tool is required.

Source
“Plastic tool to tighten Quick Turn fitting for high pressure up to 800 bar”
Safety

Stay Safe caps use a GL45 thread to fit Agilent solvent bottles and stop solvent vapor from leaching into the air.

Verifies thread compatibility before purchase and confirms the vapor-containment function for lab safety.

Source
“The GL45 thread allows to fix the Stay Safe caps to the Agilent solvent bottles”
Safety

The waste can kit requires a separate charcoal filter (5043-1193) to be functional for vapor containment.

The charcoal filter is not included, so it must be ordered separately or the waste containment will not work as intended.

Source
“requires charcoal filter (5043-1193)”
Selection

Solvent filtration is especially recommended for buffers because it prevents impurities from clogging the system filter or column and causing excessive pressure.

Buffer users must include a filtration assembly and 0.2 µm membranes in their setup to avoid overpressure and column clogging.

Source
“especially recommended for buffers”
Selection

A 10 µm stainless steel inlet filter is recommended over the standard glass filter for buffers and LC/MS applications.

Guides the correct inlet filter choice when running buffers or MS detection, where the standard glass filter is inadequate.

Source
“Smaller pore size than standard glass filter, recommended for buffers and LC/MS”
Maintenance

Preventive maintenance kits are justified by a study showing over 30% cost reduction from less downtime and troubleshooting.

Supports the decision to stock PM kits as part of the instrument purchase and planned maintenance schedule.

Source
“conducting PM can reduce system downtime and troubleshooting leading to higher than 30% cost reduction”
Selection

The high-flow Quick Connect heat exchanger (0.12 mm id, 3.0 µL) is intended for flow rates above about 2.5 mL/min.

Selecting the wrong heat exchanger volume for the method flow rate degrades gradient performance and peak shape.

Source
“For high flow rate above ca. 2.5 mL/min”
Performance

The low-dispersion heat exchanger kit (0.075 mm id, 1.1 µL) is chosen to reduce sample dispersion and improve sensitivity.

For sensitive low-flow methods the low-dispersion option must be selected instead of the high-flow version.

Source
“Reduce sample dispersion to improve sensitivity”
Maintenance

Spare deuterium lamps are recommended to be kept on hand to avoid system downtime when the installed lamp reaches end of life.

Justifies stocking a spare lamp matched to the specific detector model as part of uptime planning.

Source
“Spare lamp for detector to avoid system downtimes if lamp is at the end of its life”
Conformité

The convenience kit includes certified vials and bonded pre-slit caps, which supports validated, reproducible sample handling.

Certified consumables matter when the lab must demonstrate consistent sample integrity for regulated methods.

Source
“4 packs of 100 certified vials clear (5182-0715)”