Petite Fleur

Sommaire

  1. Overview p. 1
    Product introduction and general description of the Petite Fleur unit
  2. Spec p. 2
    Technical specifications according to DIN 12876 standard
  3. p. 2 table, 12 rows
  4. p. 1 table, 32 rows

Technical data according to DIN 12876

ParameterValue
Filling capacity expansion tank2 l
Overall dimensions WxDxH **260x450x504 mm
Net weight45 kg
sound pressure level +/- 4 dB(A)58 dB(A)
Power supply requirement110-120V 1~ 60Hz
max. current14,5 A
Fuse16 A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S610246

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876

ParameterValue
Operating temperature range-40...200 °C
Temperature stability at -10°C0,01 K
temperature set point / display5,7" colour Touchscreen
Resolution of display0,01 K
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
digital inputECS ONE
digital outputPOKO ONE
Alarm messageoptic, acoustic, relay
Safety classificationIII / FL
Heating power1,5 kW
Cooling power with Thermooil at 200°C0,48 kW
Cooling power with Thermooil at 150°C0,48 kW
Cooling power with Thermooil at 100°C0,48 kW
Cooling power with Thermooil at 50°C0,48 kW
Cooling power with Thermooil at 20°C0,48 kW
Cooling power with Ethanol at 0°C0,45 kW
Cooling power with Ethanol at -20°C0,27 kW
Cooling power with Ethanol at -30°C0,16 kW
Cooling power with Ethanol at -40°C0,04 kW
Refrigeration machineair-cooled, natural refrigerant
Refrigerant (ASHRAE, GHS)R-290 (A3, H220)
Global Warming Potential (GWP)0,02
Refrigerant quantity0,08 kg
CO2-Äquvivalent0,0 t
UN-numberUN 3358
Circulation pump: max. delivery25 l/min
Circulation pump: max. delivery pressure0,9 bar
Pump connectionM16x1 male
max. permissible kin. viscosity50 mm²/s
min. filling capacity1,5 l

Engineering Facts

12 facts · every claim linked to a page
Selection

The unit is rated for an operating temperature range of -40 to 200 °C, which defines the process window it can serve.

Confirms whether the circulator covers the required process temperatures before selection.

Source
“Operating temperature range -40...200 °C”
Selection

Cooling capacity drops sharply at low temperatures with ethanol, from 0.45 kW at 0 °C to 0.04 kW at -40 °C, so low-temperature heat loads must be sized accordingly.

Prevents oversizing expectations and ensures the process heat load is removable at the target temperature.

Source
“Cooling power with Ethanol at 0°C 0,45 kW at -20°C 0,27 kW at -30°C 0,16 kW at -40°C 0,04 kW”
Safety

The refrigerant is R-290 (A3, H220), a flammable natural refrigerant, which affects installation location and ventilation requirements.

Flammable refrigerant classification drives site safety and ventilation planning.

Source
“Refrigerant (ASHRAE, GHS) R-290 (A3, H220)”
Installation

The unit requires a 110-120 V 1~ 60 Hz supply with a maximum current of 14.5 A and a 16 A fuse.

Determines electrical supply, breaker sizing and plug configuration at the installation site.

Source
“Power supply requirement 110-120V 1~ 60Hz max. current 14,5 A Fuse 16 A”
Installation

The device is IP20 and must be operated between 5 °C and 40 °C ambient, so it cannot be placed in wet or hot environments.

Sets environmental limits for the installation location and enclosure requirements.

Source
“Degree of Protection IP20 min. ambient temperature 5 °C max. ambient temperature 40 °C”
Performance

Cooling capacity is specified at 20 °C room temperature and may drop if ambient temperature rises.

Engineers must derate cooling performance in warm rooms to avoid undersized cooling.

Source
“Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.”
Installation

Voltage and frequency tolerances are ±5% and ±2% respectively, but not simultaneously in opposite directions.

Defines acceptable mains quality for reliable operation and warranty compliance.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Conformité

The equipment is EMC classified as Class A, Group 1 to EN55011, which is intended for industrial environments.

Class A equipment may cause interference in residential areas and affects EMC planning.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Installation

Single/two-phase devices are delivered with a power cable and country-specific plug that must be specified at ordering.

Ensures the correct plug is supplied and avoids delays or rework at commissioning.

Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Operation

The pump delivers up to 25 l/min at 0.9 bar and accepts fluids up to 50 mm²/s kinematic viscosity.

Confirms hydraulic capability for the external circuit and compatible heat transfer fluids.

Source
“max. delivery 25 l/min max. delivery pressure 0,9 bar”
Operation

The minimum filling capacity is 1.5 l and the expansion tank holds 2 l, which sets the minimum system volume.

Prevents underfilling and ensures adequate expansion volume for the loop.

Source
“min. filling capacity 1,5 l”
Safety

The unit has adjustable overtemperature protection according to DIN 12876 and safety classification III/FL.

Confirms built-in safety limiting for unattended or critical operation.

Source
“With adjustable overtemperature protection according to DIN 12876.”