Introduces the Unichiller 075w model and its main features
Specpp. 1-2
Performance, temperature, and dimensional data according to DIN 12876
p. 2table, 12 rows
p. 1table, 35 rows
Technical data according to DIN 12876
Parameter
Value
min. filling capacity
18 l
Volume of expansion
48 l
Overall dimensions WxDxH **
740x1160x1050 mm
Net weight
300 kg
Power supply (3 Phase)
400V 3~ 50Hz
max. current (3 Phase)
7,5 A
Fuse (3 phase)
3x10A
Pressure equipment category
Art. 4.3 PED
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
S430098
** Please respect space requirements. See operating conditions at www.huber-online.com
Technical data according to DIN 12876 — Unichiller 075w (Order-No.: 3040.0009.01)
Parameter
Value
Operating temperature range
-20...40 °C
temperature set point / display
5,7" colour Touchscreen
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Temperature stability at -10°C
0,5 K
Interface digital
Ethernet, USB (Host u. Device), RS232
Safety classification
I / NFL
Cooling power at ambient temperature +20°C
at 20°C
7,5 kW
at 0°C
6,1 kW
at -10°C
4 kW
at -20°C
2,4 kW
Refrigeration machine
water-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-449A (A1, H280)
Global Warming Potential (GWP)
1397
Refrigerant quantity
0,95 kg
CO2 equivalent
1,3 t
Circulation pump
E1
max. delivery
48 l/min
max. delivery pressure
3,4 bar
Delivery at 0,3 bar
46 l/min
Delivery at 0,5 bar
44 l/min
Delivery at 1,0 bar
40 l/min
Delivery at 1,5 bar
33 l/min
Delivery at 2,0 bar
27 l/min
Delivery at 2,5 bar
20 l/min
Delivery at 3,0 bar
11 l/min
Pump connection
G1 1/4 male
Cooling water connection
G1/2 male
Consumption at water 15°C, flow 20°C
348 l/h
Consumption at water 15°C, flow 0°C
330 l/h
Consumption at water 15°C, flow -10°C
270 l/h
Consumption at water 15°C, flow -20°C
240 l/h
min. cooling water differential pressure
0,5 bar
max. cooling water pressure
6 bar
Engineering Facts
12 facts · every claim linked to a page
Installation
The chiller is water-cooled and requires a cooling water supply with a minimum differential pressure of 0.5 bar and a maximum pressure of 6 bar.
Ensures the cooling water circuit can provide adequate flow and pressure without overpressurizing the unit.
Source
“min. cooling water differential pressure 0,5 bar”
Installation
The unit must be operated with cooling water intake temperature between 5°C and 20°C, and if below the condensation point, the cooling water pipes inside the unit must be insulated.
Prevents condensation and ensures proper cooling performance and reliability.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance
Cooling power drops as cooling water temperature increases, and the required cooling water flow rate may increase.
Helps in sizing the cooling water supply and predicting performance under varying conditions.
Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Installation
The cooling water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE, and EPDM, so only suitable cooling water should be used.
Guides water quality requirements to avoid corrosion or damage to the cooling circuit.
Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Conformité
Voltage tolerance is ±5% with simultaneous frequency tolerance of ±2%, but combinations like -5% voltage and +2% frequency are not allowed.
Ensures the power supply meets the unit's requirements and avoids invalid tolerance combinations.
Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Installation
Three-phase devices with current consumption less than 63A are supplied with a cable but without a plug.
Requires the installer to provide a suitable plug and connection, affecting installation planning.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Safety
The refrigerant R-449A has a Global Warming Potential of 1397 and a CO2 equivalent of 1.3 t, which must be considered for environmental compliance.
Relevant for refrigerant handling, leak reporting, and environmental regulations.
Source
“Global Warming Potential (GWP) 1397”
Operation
The unit has a minimum filling capacity of 18 l and an expansion volume of 48 l, which must be respected for proper operation.
Ensures the system is filled correctly to avoid pump cavitation or overflow.
Source
“min. filling capacity 18 l”
Installation
The unit requires a 400V 3-phase 50Hz power supply with a maximum current of 7.5A and fuses of 3x10A.
Essential for electrical installation and ensuring the supply matches the unit's requirements.
Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Operation
The maximum ambient temperature for operation is 40°C and the minimum is 5°C.
Ensures the installation location maintains suitable ambient conditions for reliable operation.
Source
“max. ambient temperature 40 °C”
Maintenance
The unit uses a water-cooled refrigerating machine that is CFC- and HCFC-free, with refrigerant R-449A.
Indicates environmental compliance and maintenance requirements for the refrigerant circuit.
Source
“Refrigeration machine water-cooled, CFC- and HCFC-free”
Performance
The circulation pump delivers a maximum flow of 48 l/min and a maximum pressure of 3.4 bar, with flow decreasing at higher pressures.
Helps in designing the external circuit to match pump performance and avoid excessive pressure drop.