Unichiller 300Tw-H Datasheet

Sommaire

  1. Overview p. 1
    Introduces the Unichiller 300Tw-H chiller and its main features
  2. Spec pp. 1-2
    Lists performance, temperature, and physical specifications per DIN 12876
  3. p. 2 table, 6 rows
  4. p. 1 table, 33 rows

Technical data according to DIN 12876

ParameterValue
Power supply (3 Phase)400V 3~ 50Hz
Pressure equipment categoryI
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:1.0/19

Technical data according to DIN 12876 — Unichiller 300Tw-H (Order-No.: 3029.0036.01)

CharacteristicValue
Operating temperature range-20...100 °C
temperature set point / display5,7" colour Touchscreen
Internal temperature sensorPt100
Sensor external connectionPt100
Temperature stability at -10°C0,2 K
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationIII / FL
Heating power2 kW
Cooling power at 15°C30 kW
Cooling power at 0°C18 kW
Cooling power at -10°C13 kW
Cooling power at -20°C8 kW
Refrigeration machinewater-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-449A (A1, H280)
Global Warming Potential (GWP)1397
Circulation pumpD3
max. delivery210 l/min
max. delivery pressure4,7 bar
Delivery at 1,1 bar202 l/min
Delivery at 1,5 bar193 l/min
Delivery at 2,0 bar179 l/min
Delivery at 2,5 bar159 l/min
Delivery at 3,0 bar140 l/min
Delivery at 3,5 bar115 l/min
Delivery at 4,0 bar77 l/min
Delivery at 4,5 bar31 l/min
Pump connectionG1 1/4 male
Cooling water connectionG3/4 male
min. cooling water differential pressure1 bar
max. cooling water pressure6 bar
min. filling capacity15 l
Volume of expansion22 l
Overall dimensions WxDxH **760x800x1615 mm

** Overall dimensions WxDxH — как напечатано в исходном тексте.

Engineering Facts

13 facts · every claim linked to a page
Installation

The chiller requires a three-phase 400 V supply, so the site must provide a suitable 3-phase power connection.

Determines electrical infrastructure and whether a 3-phase feed is available at the installation point.

Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Installation

The unit is rated IP20, so it must be installed in a dry indoor location protected from water and dust ingress.

Affects placement and enclosure requirements to avoid moisture/dust damage.

Source
“Degree of Protection IP20”
Installation

Ambient temperature must stay between 5 °C and 40 °C for reliable operation.

Room conditions must be checked during site selection to avoid derating or faults.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Installation

Cooling water supply must be between 5 °C and 20 °C inlet temperature, and pipes must be insulated if below the condensation point.

Cooling water temperature directly affects cooling capacity and condensation risk.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Installation

Cooling water differential pressure must be at least 1 bar and must not exceed 6 bar.

Ensures adequate flow without overpressurizing the water circuit.

Source
“min. cooling water differential pressure 1 bar max. cooling water pressure 6 bar”
Performance

Cooling capacity drops as water temperature decreases, from 30 kW at 15 °C to 8 kW at -20 °C.

Needed to verify the chiller can handle the process heat load at the required setpoint.

Source
“at 15°C 30 kW at 0°C 18 kW at -10°C 13 kW at -20°C 8 kW”
Performance

The circulation pump delivers 210 l/min max and 202 l/min at 1.1 bar, with pressure-dependent flow decline.

Must be matched to the external circuit pressure drop to ensure adequate flow.

Source
“max. delivery 210 l/min”
Installation

Pump and cooling water connections are G1 1/4 male and G3/4 male respectively, so matching fittings are required.

Determines hose/pipe adapters needed for commissioning.

Source
“Pump connection G1 1/4 male Cooling water connection G3/4 male”
Operation

The unit uses R-449A refrigerant with GWP 1397, which has environmental reporting implications.

Affects refrigerant handling, leak reporting, and environmental compliance.

Source
“R-449A (A1, H280) Global Warming Potential (GWP) 1397”
Conformité

Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and certain combinations are not allowed.

Power quality must be verified to avoid voiding warranty or causing malfunction.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Installation

Three-phase devices under 63 A are supplied with cable but without a plug, so a suitable plug must be provided on site.

Affects electrical installation planning and commissioning.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Safety

The unit has adjustable overtemperature protection according to DIN 12876, which must be set for the application.

Critical for protecting the process and preventing overheating.

Source
“With adjustable overtemperature protection according to DIN 12876.”
Maintenance

Cooling water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water quality should be used.

Prevents corrosion and fouling that could reduce cooling performance.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”