Unichiller P025w Datasheet

Sommaire

  1. Overview p. 1
    Introduces the Unichiller P025w chiller and its main features
  2. Spec pp. 1-2
    Performance, temperature, and dimensional data per DIN 12876
  3. p. 2 table, 11 rows
  4. p. 1 table, 31 rows

Technical data according to DIN 12876

ParameterValue
Overall dimensions WxDxH **420x487x579 mm
Net weight68 kg
sound pressure level +/- 4 dB(A)60 dB(A)
Power supply requirement208-230V 1~/2~ 60Hz
max. current12,5 A
Fuse16 A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:1.1/24

** Please respect space requirements. See operating conditions at www.huber-online.com

Unichiller P025w — Technical data according to DIN 12876

CharacteristicValue
Order-No.3052.0031.01
Operating temperature range-10...40 °C
temperature set point / display5,7" colour Touchscreen
Internal temperature sensorPt100
Temperature stability at -10°C0,5 K
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationI / NFL
Cooling power at ambient temperature +20°C at 15°C2,5 kW
Cooling power at ambient temperature +20°C at 0°C2 kW
Cooling power at ambient temperature +20°C at -10°C1,2 kW
Refrigeration machinewater-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)R-449A (A1, H280)
Global Warming Potential (GWP)1397
Refrigerant quantity0,4 kg
CO2 equivalent0,6 t
Circulation pumpB
max. delivery25 l/min
max. delivery pressure2,5 bar
Delivery at 0,5 bar21 l/min
Delivery at 1,0 bar17 l/min
Delivery at 1,5 bar11 l/min
Delivery at 2,0 bar6 l/min
Pump connectionG3/4 male
Cooling water connectionG1/2 male
Consumption at water 15°C, flow 15°C84 l/h
Consumption at water 15°C, flow 0°C84 l/h
Consumption at water 15°C, flow -10°C72 l/h
min. cooling water differential pressure1 bar
max. cooling water pressure6 bar
min. filling capacity3,8 l
Volume of expansion1,7 l

Значения приведены дословно по тексту страницы; строки 'Cooling power at ambient temperature +20°C' с подпунктами at 15°C / at 0°C / at -10°C объединены в одну характеристику с указанием подпункта.

Engineering Facts

13 facts · every claim linked to a page
Selection

The chiller is water-cooled, so the facility must provide a cooling water circuit with at least 1 bar differential pressure and no more than 6 bar.

Cooling water supply pressure must be verified before selection; too low a differential pressure will not achieve rated cooling.

Source
“min. cooling water differential pressure 1 bar”
Installation

Cooling water inlet temperature must be kept between 5 °C and 20 °C, and pipes must be insulated if condensation can occur.

Defines the permissible cooling water supply temperature range for correct installation and to avoid condensation.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance

Rated cooling power is only valid at 20 °C room temperature, 15 °C cooling water inlet and 1 bar differential pressure, so actual capacity will differ otherwise.

Prevents overestimating cooling capacity when site conditions differ from the rating basis.

Source
“Output data valid for: Room temperature 20°C, cooling water inlet 15°C and 1 bar differential pressure between cooling water inlet and -”
Operation

Higher cooling water temperature reduces cooling power and may require a higher cooling water flow rate.

Affects expected performance and cooling water supply sizing in warm facilities.

Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate”
Safety

The plastic pump is not resistant to acetone or polyglycols, so these fluids must not be used without a more resistant pump option.

Critical for fluid selection and material compatibility; wrong fluid can damage the pump.

Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Operation

For freeze protection, water should be mixed with glysantine or ethylene glycol rather than relying on pure water.

Guides heat transfer fluid preparation to prevent freezing at low temperatures.

Source
“It is recommended that water is mixed with either glysantine or ethylene glycol for freeze protection.”
Installation

The unit requires a 208–230 V single/two-phase 60 Hz supply with a 16 A fuse and maximum current of 12.5 A.

Electrical supply and protection must be sized accordingly during installation.

Source
“Power supply requirement 208-230V 1~/2~ 60Hz”
Conformité

Voltage and frequency tolerances must be applied simultaneously: ±5% voltage with ±2% frequency, and certain combinations are not allowed.

Ensures the site power quality is within the allowed envelope before commissioning.

Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Installation

The unit has IP20 protection, so it must be installed in a dry environment protected from water ingress.

Determines suitable installation location and enclosure requirements.

Source
“Degree of Protection IP20”
Installation

Ambient temperature must remain between 5 °C and 40 °C for proper operation.

Site ambient conditions must be checked to avoid operating outside the allowed range.

Source
“min. ambient temperature 5 °C”
Selection

The refrigerant R-449A has a GWP of 1397 and a CO2 equivalent of 0.6 t, which matters for environmental compliance and reporting.

Relevant for refrigerant regulations and CO2-equivalent reporting at the facility.

Source
“Global Warming Potential (GWP) 1397”
Installation

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.

Guides cooling water quality and material compatibility to prevent corrosion.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Installation

Three-phase devices below 63 A are supplied with cable but without a plug, so a suitable plug must be provided on site.

Affects electrical installation planning and required accessories.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”