Unistat GL P540w Technical Data

Sommaire

  1. Overview p. 1
    Product introduction and general description of the unit
  2. Spec pp. 1-2
    Technical data and performance specifications per DIN 12876
  3. p. 2 table, 17 rows
  4. p. 1 table, 30 rows

Technical data according to DIN 12876

ParameterValue
Delivery at 5,0 bar42 l/min
Pump connectionM38x1,5 male
max. permissible kin. viscosity100 mm²/s
Cooling water connectionG3/4 male
min. cooling water differential pressure1 bar
max. cooling water differential pressure4 bar
max. cooling water pressure6 bar
max. System pressure6 bar
min. filling capacity8,9 l
Filling capacity expansion tank19,9 l
Overall dimensions WxDxH **918x963x1771 mm
Power supply requirement400V 3~ 50Hz
Pressure equipment categoryI
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:1.0/24

** Please respect space requirements. See operating conditions at www.huber-online.com

Unistat GL P540w — Technical data according to DIN 12876

ParameterValue
Order-No.5040.0002.01
Operating temperature range-50...200 °C
Temperature stability at -10°C0,01 K
temperature set point / display5,7" colour Touchscreen
Resolution of display0,01 K
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
digital inputECS ONE
digital outputPOKO ONE
Interface analogoptional
Alarm messageoptic, acoustic, relay
Safety classificationIII / FL
Heating power12 kW
Cooling power with Thermooil at 200°C28 kW
Cooling power with Thermooil at 100°C28 kW
Cooling power with Thermooil at 20°C28 kW
Cooling power with Ethanol at 0°C25 kW
Cooling power with Ethanol at -20°C17 kW
Cooling power with Ethanol at -40°C6,8 kW
Cooling power with Ethanol at -50°C4 kW
Refrigeration machinewater-cooled, natural refrigerant
Refrigerant (ASHRAE, GHS)R-744 (A1, H280)
Global Warming Potential (GWP)1
Circulation pump: MK pump max. delivery201 l/min
Circulation pump: MK pump max. delivery pressure5,3 bar
Delivery at 1,0 bar179 l/min
Delivery at 2,0 bar154 l/min
Delivery at 3,0 bar124 l/min
Delivery at 4,0 bar87 l/min

Значения приведены дословно по тексту страницы; строки 'Cooling power with Thermooil' и 'Cooling power with Ethanol' объединены с соответствующими температурными точками.

Engineering Facts

14 facts · every claim linked to a page
Installation

The unit requires a 400 V three-phase supply, so the site must provide a 3~ 50 Hz feed sized for the 12 kW heater and 28 kW cooling load.

Determines electrical infrastructure and breaker/cable sizing before purchase.

Source
“Power supply requirement 400V 3~ 50Hz”
Installation

Cooling water must be supplied at 1–4 bar differential and no more than 6 bar, with 5–20 °C intake, so the facility water loop must be verified.

Insufficient or excessive cooling water pressure will prevent rated cooling performance or damage the circuit.

Source
“min. cooling water differential pressure 1 bar max. cooling water differential pressure 4 bar max. cooling water pressure 6 bar”
Installation

Cooling water connections are G3/4 male and the pump connection is M38x1.5 male, so mating hoses and adapters must be ordered accordingly.

Prevents mismatch of process and cooling water plumbing at commissioning.

Source
“Pump connection M38x1,5 male”
Installation

The unit is IP20, so it must be installed in a dry indoor location protected from water ingress.

Affects placement and enclosure requirements in the plant.

Source
“Degree of Protection IP20”
Installation

Ambient temperature must stay between 5 °C and 40 °C, so the installation room needs adequate ventilation and climate control.

Operation outside this range risks derating or equipment fault.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Installation

The unit is water-cooled with natural refrigerant R-744 (GWP 1), so no refrigerant handling certification for high-GWP fluids is needed but water cooling is mandatory.

Confirms cooling medium availability requirement and low environmental impact for permitting.

Source
“Refrigeration machine water-cooled, natural refrigerant”
Operation

Rated cooling power is stated at 20 °C room, 15 °C cooling water inlet and 1 bar differential, so actual capacity will drop if site conditions differ.

Prevents overestimating available cooling at the customer's real water temperature.

Source
“Output data valid for: Room temperature 20°C, cooling water inlet 15°C and 1 bar differential pressure between cooling water inlet and -”
Operation

If cooling water is colder than the condensation point, the cooling water pipes inside the unit must be insulated.

Avoids condensation and corrosion inside the unit at low water temperatures.

Source
“When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Operation

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.

Guides water quality and treatment to prevent corrosion and fouling.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Conformité

Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and combinations like -5% voltage with +2% frequency are not allowed.

Defines acceptable grid quality for warranty and reliable operation.

Source
“-5% voltage and +2% frequency -> not allowed!”
Installation

Three-phase devices under 63 A are delivered with cable but without plug, so a suitable plug must be sourced and fitted on site.

Affects electrical installation scope and cost.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Safety

The unit has adjustable overtemperature protection per DIN 12876 and safety classification III/FL, so it can be used for flammable fluids with proper setup.

Confirms suitability and required safety setting for flammable heat transfer fluids.

Source
“With adjustable overtemperature protection according to DIN 12876.”
Performance

The MK pump delivers 201 l/min max at 5.3 bar, dropping to 42 l/min at 5.0 bar, so system pressure drop must be checked against the pump curve.

Ensures adequate flow through the external process loop.

Source
“max. delivery 201 l/min max. delivery pressure 5,3 bar”
Maintenance

Minimum filling capacity is 8.9 l and expansion tank capacity is 19.9 l, so the heat transfer fluid volume and expansion allowance must be planned.

Prevents underfilling and overflow during thermal expansion.

Source
“min. filling capacity 8,9 l Filling capacity expansion tank 19,9 l”