Unistat T350 Temperature Control System Technical Data
Sommaire
Overviewp. 1
Product introduction and model identification for Unistat T350
Specp. 2
Technical data per DIN 12876 including performance and dimensions
p. 1table, 25 rows
Unistat T350 Technical data according to DIN 12876
Characteristic
Value
Order-No.
1025.0016.01
Operating temperature range
65... 300 °C
Temperature stability at 70°C
0,01 K
temperature set point / display
5,7" colour Touchscreen
Resolution of display
0,01 K
Internal temperature sensor
Pt100
External sensor
Pt100
Interface digital
Ethernet, USB (Host u. Device), RS232
digital input
ECS ONE
digital output
POKO ONE
Alarm message
optic, acoustic, relay
Safety classification
III / FL
Heating power
96 kW
Circulation pump:
MK pump
max. delivery
200 l/min
max. delivery pressure
5,5 bar
Pump connection
M38x1,5 male
max. permissible kin. viscosity
50 mm²/s
Filling capacity expansion tank
56 l
Overall dimensions WxDxH **
800x1007x1607 mm
Power supply (3 Phase)
400V 3~ 50Hz
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.
1.0/25
** Technical details and dimensions are subject to change. No liability is accepted for errors or omissions. Illustrations can deviate from the original.
Engineering Facts
13 facts · every claim linked to a page
Selection
The unit has no active refrigeration, so reaching 65 °C requires adequate heat loss from the application or suitable water cooling.
Prevents selecting the unit expecting active cooling below ambient; cooling depends on application heat loss or external water cooling.
Source
“These devices do not have an active refrigeration system.”
Installation
For water-cooled operation, target temperatures down to 65 °C can only be achieved with appropriate heat loss from the application or suitable water cooling.
Requires planning of water cooling or verification of application heat loss to meet the minimum temperature.
Source
“Water cooled: Target temperatures (down to the minimum 65°C) can only be achieved with appropriate heat loss from the application or suitable water cooling.”
Installation
For air-cooled operation, the heat loss must be between 0.1 kW and 2.8 kW depending on the unit, and ambient temperature must be well below 60 °C to reach 65 °C.
Defines the allowable application heat loss window and ambient condition for air-cooled installations.
Source
“Air cooled: The heat loss must be between 0.1kW and 2.8kW, depending on the unit.”
Installation
Three-phase devices drawing less than 63 A are supplied with a cable but without a plug.
The installer must provide and fit a suitable plug for the 400 V three-phase supply.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation
Three-phase devices drawing more than 63 A are supplied without cable and without plug.
Requires the customer to supply and install the power cable and plug for high-current three-phase units.
Source
“Three-phase devices with current consumption greater than 63A --> without cable, without plug”
Conformité
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and certain combinations such as -5% voltage with +2% frequency are not allowed.
Ensures the site power quality meets EN60034-1 limits before installation and commissioning.
Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Safety
The equipment has a leakage current greater than 3.5 mA, which must be considered for protective earthing and RCD selection.
Affects electrical installation design, earthing, and residual current device selection.
Source
“Attention: leakage current > 3,5mA”
Installation
The pump connection is an M38x1.5 male thread with bore shape Y (60°) according to DIN 3863, so matching hoses or adapters are required.
Determines the mating hose fittings and adapters needed for the external circuit.
Source
“Pump connection M38x1,5 male”
Operation
The maximum permissible kinematic viscosity of the circulating fluid is 50 mm²/s.
Limits the choice of thermofluid and ensures pump performance and protection.
Source
“max. permissible kin. viscosity 50 mm²/s”
Installation
The unit requires a 400 V 3~ 50 Hz three-phase power supply.
Defines the site electrical supply required for installation.
Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Installation
The degree of protection is IP20, so the unit must be installed in a dry, protected environment.
Restricts installation location regarding moisture and dust ingress.
Source
“Degree of Protection IP20”
Operation
The permissible ambient temperature range is 5 °C to 40 °C.
Ensures the installation site stays within the allowed ambient conditions for reliable operation.
Source
“min. ambient temperature 5 °C”
Installation
Space requirements must be respected according to the operating conditions.
Prevents installation in insufficient space that could affect cooling and access.
Source
“Please respect space requirements. See operating conditions at www.huber-online.com”