SPME Arrow selection set 2 – PDMS (1.10 mm, 100 μm); polyacrylate (1.10 mm, 100 μm); CWR/PDMS (1.10 mm, 120 μm); DVB/PDMS (1.10 mm, 120 μm); DVB/CWR/PDMS (1.10 mm, 120 μm)
1.1 mm
20 mm
Multiple
Multiple
5 pack
5610-5869
Arrow
Yes
Smart SPME Arrow selection set 2 – Smart SPME Arrow, PDMS (1.10 mm, 100 μm); Smart SPME Arrow polyacrylate (1.10 mm, 100 μm); Smart SPME Arrow, CWR/PDMS (1.10 mm, 120 μm); Smart SPME Arrow, DVB/PDMS (1.10 mm, 120 μm); Smart SPME Arrow, DVB/CWR/PDMS (1.10 mm, 120 μm)
1.10 mm
20 mm
Multiple
Multiple
5 pack
5191-5868
Arrow
No
SPME Arrow selection set 1 – PDMS (1.10 mm, 100 μm); polyacrylate (1.10 mm, 100 μm); CWR/PDMS (1.10 mm, 120 μm); DVB/PDMS (1.10 mm, 120 μm); PDMS (1.50 mm, 250 μm)
Multiple
20 mm
Multiple
Multiple
5 pack
5610-5868
Arrow
Yes
Smart SPME Arrow selection set 1 – Smart SPME Arrow, PDMS (1.10 mm, 100 μm); Smart SPME Arrow polyacrylate (1.10 mm, 100 μm); Smart SPME Arrow, CWR/PDMS (1.10 mm, 120 μm); Smart SPME Arrow, DVB/PDMS (1.10 mm, 120 μm); Smart SPME Arrow, PDMS, (1.50 mm, 250 µm)
Multiple
20 mm
Multiple
Multiple
5 pack
Table 1. SPME fibers and Arrows in the Agilent SPME product portfolio.
Part Number
Fiber/Arrow
Smart
Product Description
Fiber Gauge/Arrow od
Phase Length
Phase Thickness
Color
Pack
5191-5877, G7371-67001
Both
No
Manual injection kit for SPME fiber and SPME Arrow
NA
NA
NA
NA
1 each
5191-5876
Fiber
No
Acrylate (polyacrylate)
23
10 mm
85 µm
Gray
3 pack
5610-5876
Fiber
Yes
Acrylate (polyacrylate)
23
10 mm
86 µm
Gray
3 pack
5191-5858
Arrow
No
Acrylate (polyacrylate)
1.1 mm
20 mm
100 µm
Gray
3 pack
5610-5858
Arrow
Yes
Acrylate (polyacrylate)
1.10 mm
20 mm
100 µm
Gray
3 pack
5191-5875
Fiber
No
Carbon WR/PDMS (carbon wide range/PDMS)
23
10 mm
95 µm
Dark blue
3 pack
5610-5875
Fiber
Yes
Carbon WR/PDMS (carbon wide range/PDMS)
23
10 mm
95 µm
Dark blue
3 pack
5191-5859
Arrow
No
Carbon WR/PDMS (carbon wide range/PDMS)
1.1 mm
20 mm
120 µm
Light blue
3 pack
5191-5863
Arrow
No
Carbon WR/PDMS (carbon wide range/PDMS)
1.5 mm
20 mm
120 µm
Light blue
3 pack
5610-5859
Arrow
Yes
Carbon WR/PDMS (carbon wide range/PDMS)
1.10 mm
20 mm
120 µm
Light blue
3 pack
5610-5863
Arrow
Yes
Carbon WR/PDMS (carbon wide range/PDMS)
1.50 mm
20 mm
120 µm
Light blue
3 pack
5191-5874
Fiber
No
DVB/carbon WR/PDMS
23
10 mm
80 µm
Dark gray
3 pack
5610-5874
Fiber
Yes
DVB/carbon WR/PDMS
23
10 mm
80 µm
Dark gray
3 pack
5191-5861
Arrow
No
DVB/carbon WR/PDMS
1.1 mm
20 mm
120 µm
Dark gray
3 pack
5191-5864
Arrow
No
DVB/carbon WR/PDMS
1.5 mm
20 mm
120 µm
Dark gray
3 pack
5610-5861
Arrow
Yes
DVB/carbon WR/PDMS
1.10 mm
20 mm
120 µm
Dark gray
3 pack
5610-5864
Arrow
Yes
DVB/carbon WR/PDMS
1.50 mm
20 mm
120 µm
Dark gray
3 pack
5191-5870
Fiber
No
PDMS (polydimethylsiloxane)
23
10 mm
7 µm
Green
3 pack
5610-5870
Fiber
Yes
PDMS (polydimethylsiloxane)
23
10 mm
7 µm
Green
3 pack
5191-5871
Fiber
No
PDMS (polydimethylsiloxane)
23
10 mm
30 µm
Yellow
3 pack
5610-5871
Fiber
Yes
PDMS (polydimethylsiloxane)
23
10 mm
30 µm
Yellow
3 pack
5191-5872
Fiber
No
PDMS (polydimethylsiloxane)
23
10 mm
100 µm
Red
3 pack
5610-5872
Fiber
Yes
PDMS (polydimethylsiloxane)
23
10 mm
100 µm
Red
3 pack
5191-5862
Arrow
No
PDMS (polydimethylsiloxane)
1.1 mm
20 mm
100 µm
Red
3 pack
5191-5866
Arrow
No
PDMS (polydimethylsiloxane)
1.5 mm
20 mm
100 µm
Red
3 pack
5610-5862
Arrow
Yes
PDMS (polydimethylsiloxane)
1.10 mm
20 mm
100 µm
Red
3 pack
5610-5866
Arrow
Yes
PDMS (polydimethylsiloxane)
1.50 mm
20 mm
100 µm
Red
3 pack
5191-5867
Arrow
No
PDMS (polydimethylsiloxane)
1.5 mm
20 mm
250 µm
Black
3 pack
5610-5867
Arrow
Yes
PDMS (polydimethylsiloxane)
1.50 mm
20 mm
250 µm
Black
3 pack
5191-5873
Fiber
No
PDMS/DVB (PDMS/divinylbenzene)
23
10 mm
65 µm
Violet
3 pack
5610-5873
Fiber
Yes
PDMS/DVB (PDMS/divinylbenzene)
23
10 mm
65 µm
Violet
3 pack
5191-5860
Arrow
No
PDMS/DVB (PDMS/divinylbenzene)
1.1 mm
20 mm
120 µm
Violet
3 pack
5191-5865
Arrow
No
PDMS/DVB (PDMS/divinylbenzene)
1.5 mm
20 mm
120 µm
Violet
3 pack
5610-5860
Arrow
Yes
PDMS/DVB (PDMS/divinylbenzene)
1.10 mm
20 mm
120 µm
Violet
3 pack
5610-5865
Arrow
Yes
PDMS/DVB (PDMS/divinylbenzene)
1.50 mm
20 mm
120 µm
Violet
3 pack
Engineering Facts
14 facts · every claim linked to a page
Selection
Choose the SPME phase based on analyte molecular weight, polarity, concentration, and matrix complexity.
These four criteria drive the phase selection decision before any hardware is ordered.
Source
“These criteria include molecular weight of the target analytes, polarity of the target analytes, concentration, and the complexity of the matrix.”
Selection
For nonpolar and volatile compounds, select the 100 µm PDMS phase.
Direct phase recommendation for the most common volatile/nonpolar applications.
Source
“Nonpolar and volatile compounds usually require the 100 µm PDMS phase.”
Selection
For polar analytes in polar samples, use the 85 µm polyacrylate phase.
Prevents poor recovery when a nonpolar phase is mistakenly chosen for polar analytes.
Source
“To extract polar analytes from polar samples, use an 85 µm PA coated phase.”
Selection
For trace-level volatile analysis, the 75 µm PDMS/CWR phase is recommended.
Guides phase choice when low detection limits are the primary requirement.
Source
“For trace-level volatile analysis, the 75 µm PDMS/CWR phase is recommended.”
Selection
The PDMS coating is the most robust choice for direct analysis of complex matrices.
Robustness may outweigh sensitivity when samples are dirty or complex.
Source
“The PDMS coating is the most robust option for directly analyzing complex matrices”
Selection
SPME Arrows offer up to 6× larger sorption phase surface and up to 20× larger volume than fibers.
Determines whether a fiber or an Arrow is needed for sensitivity and phase volume.
Source
“SPME Arrows feature larger sorption phase surfaces (up to 6×) and volumes (up to 20×).”
Installation
SPME fibers use a standard 10 mm length and 23-gauge needle, while Arrows use 20 mm length with 1.1 or 1.5 mm od.
Needle gauge/od and length must match the injector, septum, and microseal hardware.
Source
“All Agilent SPME Arrows have a standard length of 20 mm with either a 1.1 or 1.5 mm outside diameter (od) needle”
Installation
Replacement microseals are size-specific for 1.1 mm and 1.5 mm Arrow probes.
Wrong microseal size causes leaks or damage; must be ordered to match the Arrow od.
Source
“Replacement microseals for use with 1.1 mm arrow SPME probes”
Operation
Time control is critical for quantitation, so automation is highly recommended.
Manual timing variability degrades reproducibility; drives the decision to automate.
Source
“Time control is critical for quantitation, thus automation is highly recommended”
Operation
Increasing sample temperature raises sensitivity for high-boiling components but lowers it for low-boiling components.
Temperature must be tuned per analyte volatility rather than simply maximized.
Source
“increasing the sample temperature will increase the sensitivity for the higher boiling components, but decrease the sensitivity for the lower boiling components”
Operation
Salting out with saturated NaCl improves extraction for many analytes but does not help in every application.
Prevents assuming salt addition is universally beneficial during method development.
Source
“salting out does not help in every application”
Operation
DI-SPME greatly improves extraction efficiency for polar and semivolatile compounds that headspace sampling handles poorly.
Drives the choice between headspace and direct immersion modes.
Source
“The extraction efficiency for polar and semivolatile compounds improves drastically when DI-SPME is performed.”
Maintenance
Solid porous phases degrade from prolonged direct exposure to complex matrices and can saturate.
Explains lifetime limits and the need for rinses and proper conditioning in DI mode.
Source
“solid porous phases show certain drawbacks associated with deterioration of the phase surface due to direct exposure to complex matrices for extended periods of time”
Maintenance
SPME phases may swell in certain solvents, and PDMS swells in nonpolar solvents such as toluene and dichloromethane.
Solvent compatibility must be checked to avoid phase damage and artifacts.
Source
“PDMS swells in contact with nonpolar solvents (such as hydrocarbons, toluene, and dichloromethane).”