Induztr
Résumé technique Visionneuse de documents Modèles associés

TwisTorr 84 FS Turbomolecular Pump Instruction Manual

Sommaire

  1. Overview pp. 1-4
    Cover page and table of contents for the manual
  2. Warning pp. 5-8
    General safety instructions for turbomolecular pumps
  3. Procedure pp. 9-12
    Preparation and mounting of the pump
  4. Spec pp. 13-16
    Technical specifications and operating parameters
  5. pp. 17-32
    Italian translation of the instruction manual
  6. pp. 33-48
    German translation of the instruction manual
  7. pp. 49-64
    French translation of the instruction manual
  8. pp. 65-80
    Spanish translation of the instruction manual
  9. pp. 81-96
    Portuguese translation of the instruction manual
  10. pp. 97-112
    Dutch translation of the instruction manual
  11. pp. 113-128
    Danish translation of the instruction manual
  12. pp. 129-144
    Swedish translation of the instruction manual
  13. pp. 145-160
    Norwegian translation of the instruction manual
  14. pp. 161-176
    Finnish translation of the instruction manual
  15. pp. 177-192
    Hungarian translation of the instruction manual
  16. pp. 193-208
    Polish translation of the instruction manual
  17. pp. 209-224
    Czech translation of the instruction manual
  18. pp. 225-240
    Slovak translation of the instruction manual
  19. pp. 241-256
    Slovenian translation of the instruction manual
  20. pp. 257-288
    English safety guidelines, storage and instructions for use
  21. Spec pp. 289-316
    Detailed technical data, dimensions and performance curves
  22. Procedure pp. 317-336
    Inlet screen, air cooling kit and purge valve installation
  23. Procedure pp. 337-348
    Venting procedure and request for return form
  24. p. 349
    Sales and service offices contact information
  25. p. 295 table, 20 rows
  26. p. 282 table, 5 rows
  27. p. 289 table, 21 rows
  28. p. 296 table, 18 rows
  29. p. 297 table, 1 rows
  30. p. 343 table, 28 rows

Tab. 3 Technical Specification

Pumping speedISO 63 / CFF 4.5”CFF 2.75”KF 40
N267 l/s56 l/s49 l/s
He63 l/s46 l/s38 l/s
H253 l/s40 l/s36 l/s
Ar66 l/s57 l/s44 l/s
Max gas throughput at full rotational speed (with recommended forepump)
N2
Ar
Air cooling100 sccm70 sccm
Water cooling100 sccm70 sccm
Compression ratio
N21 × 1011
He2 × 106
H25 × 104
Ar> 1 × 1011
Foreline Tolerance(*)
N2> 14 mbar
He> 12 mbar
H2> 4 mbar
Ar> 14 mbar
Base pressure with recommended forepump< 5 x 10-10 mbar (< 3.75 x 10-10 Torr)

(According to standard DIN 28 428, the base pressure is that measured in a leak-free test dome, 48 hours after the completion of test dome bake-out, with a Turbopump fitted with a ConFlat flange and using the recommended pre-vacuum pump) (*) The Foreline Tolerance is the pressure at which the turbopump still produce a compression of

Tab. 1

PART NUMBERCONTROLLER
X3508-64001TwisTorr 84 FS AG Rack RS232/485
X3508-64002TwisTorr 84 FS AG Rack Profibus
X3509-64000TwisTorr 84 FS on board 110/220V
X3509-64001TwisTorr 84 FS on board 24V
X3510-64000Controller TwisTorr 84 FS PCB

17 Technical Information

РазделСтраница
Description of the TwisTorr 84 FS291
Pump Description293
Technical Specification295
TwisTorr 84 FS Outline298
Interconnections314
Earth (Ground) Connection314
Connection C – Electrical315
Soft Start316
Inlet screen installation317
Air Cooling Kit Installation321
Water Cooling Kit Connection323
Vent Accessories326
Vibration Isolator Installation328
Purge Valve Installation329
TwisTorr 84 FS On Board Controller Installation330
Bottom Mounting330
Side Mounting
Connection of the High Vacuum Flange333
Installation of ISO-K Flange333
Installation of ConFlat Flange (CFF 2 ¾)335
Installation of ConFlat Flange (CFF 4 ½)335

Technical Specification

ParameterSpecification
Inlet flangeCFF 4.5" O.D.; CFF 2.75” O.D.; ISO 63; KF 40
Foreline flangeKF16 NW
Rotational speed81000 rpm (1350 Hz driving frequency)
Start-up time< 2 minutes
Recommended forepumpmechanical: Agilent DS 42; mechanical: Agilent DS 102; dry pump: Agilent IDP-7; dry pump: Agilent IDP-3
Operating positionAny
Operating ambient temperature+5 °C to +35 °C
Relative humidity of air0 – 90 % (not condensing)
Bakeout temperature80 °C at inlet flange (ISO63) and 120°C (CFF 4.5”) max
LubricantPermanent lubrication
Cooling requirementsMax forced cooling air temperature = 35°C; Max cooling water temperature = 25°C
Coolant waterMinimum flow: 65 l/h (0.30 GPM); Temperature: +15 °C to +25 °C; Pressure: 2 to 4 bar (30 to 60 psi)
Noise Pressure level (pump only)40 ± 4 dB(A) at 1 meter † (Min = 32 dB(A), Max = 48 dB(A))
Pwr supply:Input Voltage: 76 Vac, 3 Phase (provided by the controller); Input Frequency: 1350 Hz max (provided by the controller); Max input pwr: 130 VA; Stand-by pwr: 8 W; Max oper. power: 70 W (according to controller model) with water or air cooling
Installation categoryII
Pollution degree2
Storage temperature-40° C to +70° C
Max operating altitude3000 m

† average value ± standard deviation.

Weight kg (lbs):

Pump ISO 63Pump CFF 4.5’’Pump KF 40Pump CFF 2.75’’
2.05 kg3.50 Kg2.37 kg3.34 kg

Tab. 4 Accessories and spare parts

DescriptionPart Numbers
Mains cable NEMA plug, 3 m long9699958
Mains cable European plug, 3 m long9699957
Serial cable and A-Plus software9699883
Inlet screen ISO63X3502-68001
Inlet screen CFF4.5”X3502-68000
Inlet screen, KF409699309
Inlet screen CFF 2.75”9699328
Metal Water Cooling kitX3502-68002
Plastic Water cooling kitX3502-68003
Air cooling kit (0,5 m cable)9699290
Air cooling kit extension cable (5 m)9699940
Controller side mounting bracketX3502-68006
Vibration isolator ISO 639699375
Vibration isolator CFF 4.5”9699376
Vent Valve N.O. 0,5 mm orifice (0,5 m cable)9699844
Vent Valve extension cable (5 m)9699941
Vent Screw M5X3502-68005
Purge ScrewX3502-68004
Purge valve 10 SCCM NW16KF - M129699239
Purge valve 10 SCCM ¼ Swagelok - M129699240
Purge valve 20 SCCM NW16KF - M129699241
Purge valve 20 SCCM ¼ Swagelok - M129699242
Purge valve 10 SCCM ¼ Swagelok - ¼ Swagelok9699232
Purge valve 20 SCCM ¼ Swagelok - ¼ Swagelok9699236
CFF4.5 Mounting kitX3502-68007
Metric screws kitX3502-68008
American screws kitX3502-68009
Pump extension cable (3 m)9699942

Engineering Facts

14 facts · every claim linked to a page
Operation

The inlet flange temperature must not exceed 120 °C with ConFlat or 80 °C with ISO flanges during bakeout, and water cooling must always be used.

Determines bakeout limits and mandatory water cooling to avoid overheating and damage.

Source
“la temperatura sulla flangia di ingresso non deve essere superiore a 120 °C con flangiatura ConFlat e a 80 °C con flangiatura ISO. Usare sempre il raffreddamento ad acqua durante le operazioni di riscaldamento.”
Safety

Never run the pump unless the inlet flange is connected to the vacuum chamber or closed with the blank flange.

Prevents exposure to rotating parts and injury during operation.

Source
“Non far funzionare mai la pompa se la flangia di ingresso non è collegata alla camera da vuoto o non è chiusa con la flangia di chiusura.”
Maintenance

Before any intervention, disconnect power, vent the pump, wait for the rotor to fully stop, and let surface temperature drop below 50 °C.

Defines safe servicing conditions to avoid injury and equipment damage.

Source
“attendere fino al completo arresto del rotore ed attendere che la temperatura superficiale della pompa sia inferiore a 50 °C.”
Installation

The pump can be mounted in any position but must be fixed via the inlet flange to a counter-flange rated for 250 Nm torque; the base cannot be used for mounting.

Dictates the only valid mounting method and required mechanical strength.

Source
“Modell TwisTorr 84 FS kann nicht mittels seines Sockels befestigt werden.”
Installation

For ISO 63 K flanges, use 4 high-strength clamps (e.g., IC 63250 DCMZ) tightened to 22 Nm.

Specifies clamp count and torque needed for a secure, leak-free flange joint.

Source
“ISO 63 K Doppelschelle mit NM10 Gewinde 4 22 Nm”
Installation

The pump must be installed only indoors, protected from weather, dust, aggressive gases, and explosive or fire-hazard environments.

Defines environmental restrictions that rule out outdoor or hazardous-area installation.

Source
“Der Apparat nur in geschlossenen Räumen installiert werden. Er darf nicht in Umgebungen, die ungeschützt vor Wetter (Regen, Frost, Schnee), Staub und aggressiven Gasen sind, und nicht in explosionsfähigen oder erhöht brandgefährdeten Umgebungen verwendet werden.”
Operation

Operating environment must stay within +5 °C to +35 °C, 0–90 % non-condensing humidity, and max 2 bar above atmospheric pressure.

Sets the allowable ambient envelope for reliable operation.

Source
“Temperatur: von +5°C bis +35°C: Relative Luftfeuchtigkeit: 0 – 90 % (nicht kondensierend).”
Selection

The pump must be used only with one of the listed Agilent controllers and connected to a primary (backing) pump.

Constrains controller selection and requires a backing pump in the system.

Source
“Die pumpe TwisTorr 84 FS dürfen nur mit einem der passenden Agilent-Controller verwendet werden und müssen an eine Primärpumpe angeschlossen werden”
Conformité

The pump complies with installation category II per EN 61010-1, so it must be connected to a supply line matching that category.

Determines the required electrical supply category for compliant installation.

Source
“Das Modell Twis Torr 84 FS entspricht der Installationskategorie II gemäß der Norm EN 61010-1.”
Safety

The controller power cable serves as the emergency disconnect, so it must remain easily accessible and quickly unpluggable.

Requires layout planning so the cable can act as the emergency power cut-off.

Source
“Le câble d’alimentation du contrôleur a également pour fonction de couper l’alimentation électrique du contrôleur et de la pompe en cas d’urgence.”
Installation

Do not remove the adhesive tape and protective cover until the moment the turbopump is connected to the system.

Keeps the pump clean and prevents contamination before installation.

Source
“Ne décoller l'adhésif et ne retirer le couvercle de protection qu'au moment de brancher la turbopompe au système.”
Operation

The pump is a turbomolecular pump for high/ultra-high vacuum that can pump gases but is not suitable for liquids or solid particles.

Defines the media the pump can handle, ruling out liquid/particulate streams.

Source
“não são adequadas para aspirar líquidos ou partículas sólidas.”
Performance

The pump achieves its effect via a high-speed rotating turbine driven by a three-phase motor at up to 81000 rpm.

Indicates the high rotational speed relevant to vibration, balancing, and safety.

Source
“O efeito da bomba é obtido através de uma turbina rotativa de alta velocidade (81000 r.p.m. máx.)”
Operation

Maximum storage is 12 months from shipment date; exceeding it requires returning the pump to the manufacturer.

Sets a shelf-life limit that affects procurement timing and warranty.

Source
“el período máximo de almacenamiento de una bomba turbomolecular es de 12 meses a contar de la fecha de envío al cliente.”