Elmo Rietschle V-DTE
Elmo Rietschle ·Fabriqué en Germany · En production active

Elmo Rietschle V-DTE

Elmo Rietschle V-DTE — Systèmes de vide industriels et médicaux centralisés con Pression différentielle max. 1000 mbar, Puissance moteur 145 kW, Niveau sonore 58 dB.

The V-DTE is a side-channel blower configured as a single-stage, dry-running vacuum/pressure source with a G 1/8 inlet connection. It delivers 3.5 m³/h at 50 Hz (4.2 m³/h at 60 Hz) and up to 1.0 bar differential pressure, distinguishing it from larger siblings by its compact 0.12–0.145 kW motor and 6.5 kg frame. It is intended for integration into central vacuum or pressure systems where low flow and moderate pressure rise are required.

Télécharger la fiche (PDF)
Pression différentielle max.
1000 mbar
Puissance moteur
145 kW
Niveau sonore
58 dB
Vitesse de pompage
3.5 m³/h
Poids
6.5 kg

Spécifications complètes

Prestaciones y funciones principales
Pression différentielle max. 1.0 bar (50 Hz | 3~)
50 Hz | 1~: 1.0 bar
Puissance moteur 0.120 kW (50 Hz | 3~)
60 Hz | 3~: 0.145 kW · 50 Hz | 1~: 0.120 kW · 60 Hz | 1~: 0.145 kW
Niveau sonore 57 dB (50 Hz)
60 Hz: 58 dB
Vitesse de pompage 3.5 m³/hour (50 Hz)
60 Hz: 4.2 m³/hour
Vitesse de rotation 2700 - 2860 rpm (50 Hz)
a mfr 208 mm
b mfr 156 mm
c mfr 151 mm
d mfr 24 mm
l mfr 78 mm
r mfr 60 mm
øs mfr 8-10 mm
øw mfr 125 mm
R mfr G 1/8
Model code mfr V-DTE
Volume flow mfr 3.5 m3/h (50 Hz)
Volume flow mfr 4.2 m3/h (60 Hz)
Overpressure mfr 1.0 bar (3~)
Overpressure mfr 1.0 bar (1~)
ZRD mfr 6
ZRK mfr 6 (03)
Dimensiones, peso y diseño mecánico
Poids 6.5 kg
Hauteur 151 mm
Longueur 208 mm
Largeur 156 mm
Dimension a mfr 208 mm
Dimension b mfr 156 mm
Dimension c mfr 151 mm
Dimension d mfr 24 mm
Dimension l mfr 78 mm
Dimension r mfr 60 mm
Eléctrico, alimentación y accionamiento
Courant 1.12 / 0.71 A (50 Hz | 3~/1~)
60 Hz | 3~/1~: 1.02 / 0.62 A · 50 Hz | 1~: 1.3 A · 60 Hz | 1~: 1.4 A
Motor rating mfr 0.145 kW (60 Hz)
Current drawn mfr 1.3 A (50 Hz)
Current drawn mfr 1.4 A (60 Hz)
Motor starter ZMS (3~) mfr 16 / 10 A (50 Hz)
Motor starter ZMS (3~) mfr 16 / 10 A (60 Hz)
Motor starter ZMS (1~) mfr 16 A (50 Hz)
Motor starter ZMS (1~) mfr 16 A (60 Hz)
Interfaces, conexiones y control
Raccord d'entrée G 1/8
Condiciones de servicio, entorno y protección
Average noise level mfr 58 dB(A) (60 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Process Limits
Do not exceed 1.0 bar differential pressure

The maximum differential pressure is 1.0 bar for both 1~ and 3~ variants at 50 Hz. Operation above this limit can cause motor overload, excessive heating and mechanical damage. Because no separate 60 Hz pressure rating is provided, the same 1.0 bar ceiling should be applied unless the manufacturer confirms otherwise for the 60 Hz variant.

Factory Specification Sheet
Electrical
Match motor variant to supply frequency and phase

The V-DTE is available with 1~ or 3~ motors for 50 Hz or 60 Hz. Current draw differs by variant: 1.3 A (50 Hz, 1~), 1.4 A (60 Hz, 1~), 1.12/0.71 A (50 Hz, 3~/1~) and 1.02/0.62 A (60 Hz, 3~/1~). Supplying the wrong frequency or phase will alter speed, flow and pressure, and may overload the motor. Confirm the nameplate matches the site supply before connection.

Factory Specification Sheet
Mounting
Use M8 or M10 fasteners on the 125 mm bolt circle

The base has mounting holes of 8–10 mm diameter on a 125 mm circle (øw), with footprint dimensions l = 78 mm and r = 60 mm. The unit weighs 6.5 kg, so the mounting surface must be flat and rigid enough to avoid vibration transmission. Ensure fasteners are long enough to engage the base fully without protruding into the impeller chamber.

Factory Specification Sheet
Maintenance
Order ZRD, ZRK or ZMS accessories separately

The spare parts list covers the V-DTE series with accessories ZRD, ZRK and ZMS. These are not part of the base delivery and must be ordered as separate line items if required for the installation. The ZRD 6 code on this model indicates the size 6 accessory group; verify the exact accessory part number against the spare parts list before ordering.

Spare Parts List — compressor (EN

Selection & Integration Q&A

When should I choose the V-DTE size 6 instead of a larger or smaller V-DTE sibling?

Choose the size 6 when the required flow is about 3.5 m³/h at 50 Hz (4.2 m³/h at 60 Hz) and differential pressure does not exceed 1.0 bar. Smaller sizes (3) give less flow; larger sizes (8, 10) give more flow but draw higher motor power and weigh more. The size 6 is the balance point for low-flow, moderate-pressure vacuum or pressure systems.

What are the requirements for connecting the V-DTE to my vacuum system?

The inlet and discharge connections are G 1/8. Use mating fittings rated for at least 1.0 bar differential pressure and suitable for the process gas. The blower is dry-running and oil-free, so no lubricant or seal fluid is needed. Ensure piping is supported independently to avoid loading the blower casing, and include a filter on the inlet if particulate matter is present.

What maintenance and accessories are required for the V-DTE?

The blower is oil-free and requires no routine lubrication. Inspect inlet filters periodically and check for wear on the impeller and bearings after extended operation. Accessories ZRD, ZRK and ZMS are available but not included in the base delivery; order them separately if needed. Refer to the spare parts list for the size 6 (ZRD 6) part numbers.

Plans dimensionnels et documentation technique

Documentation technique

PDF
Spare Parts List — compressor (EN)
Datasheet ·149,7 КБ ·2 pp.
Voir le PDF