Waters Waters Fraction Collection III for Sample Purification
Waters Waters Fraction Collection III for Sample Purification — Automatisation et équipement de laboratoire.
The Waters Fraction Collection III is a benchtop fraction collector with a 0.1 s nozzle shift time and a maximum flow rate of 300 mL/min, designed for sample purification in laboratory workflows. It accepts 10 mV or 1 V full-scale detector signals and provides RS-232C communication, operating in environments from 2 to 40 °C. This model is suited for automated peak-based fraction collection where fast, precise tube positioning is required.
Spécifications complètes
| Nozzle shift time mfr | 0.1 s (tube center to center) |
| Power requirements mfr | 100.00 V AC / 115.00 V AC / 240.00 V AC, 0.23 A |
| External dimensions mfr | Width: 28.60 cm (11.27 in.); Depth: 35.90 cm (14 |
| Temperature range mfr | 2 to 40 °C (35 to 104 °F) |
| Maximum flow rate mfr | 300 mL per minute |
| Bench space mfr | W 311 mm × D 413 mm × H 362 mm mm |
| Poids | 7.0 kg |
| Power mfr | 0.23 A (100 V, 50 to 60 Hz) |
| Power mfr | 0.2 A (115 V, 50 to 60 Hz) |
| Power mfr | 0.15 A (240 V, 50 to 60 Hz) |
| Serial interface mfr | RS-232C (9-pin connector) |
| Signal input mfr | 10 mV or 1 V full scale |
| Operation display mfr | 40 characters by 8 rows (LCD w/backlight) |
| Relative humidity mfr | 20 to 85 % (noncondensing) |
Description
Construction and positioning
- Benchtop unit with external dimensions of 28.6 cm (W) × 35.9 cm (D) × 33.5 cm (H) and a weight of 7.0 kg. - Equipped with a 40-character × 8-row backlit LCD for operation display. ### Signal and flow behavior
- Accepts analog detector signals of 10 mV or 1 V full scale, enabling compatibility with a range of detectors. - Supports flow rates up to 300 mL/min, suitable for preparative and semi-preparative chromatography. - Nozzle shift time of 0.1 s (tube center to center) allows rapid fraction switching. - RS-232C (9-pin) serial interface for external control or data communication. - Operates within a temperature range of 2 to 40 °C (35 to 104 °F).
Integration & Operating Notes
The analog input expects either 10 mV or 1 V full-scale signals. Verify the detector output range and configure accordingly to ensure correct peak detection and fraction triggering.
The maximum supported flow rate is 300 mL per minute. Exceeding this may cause inaccurate fraction collection or mechanical stress; ensure the pump and plumbing are set within this limit.
Selection & Integration Q&A
The collector accepts analog signals of 10 mV or 1 V full scale and communicates via RS-232C (9-pin). Ensure your detector provides a compatible output and that your control system has an available serial port.
No maintenance schedule or included accessories are detailed in the provided facts. The base delivery typically includes the collector, power cord, and manual; confirm with the supplier for specific consumables like tubes and racks.