Agilent 8900 ICP-QQQ Brochure

Contents

  1. Overview pp. 1-2
    Introduction to interference removal and confident ICP-MS results
  2. Overview pp. 3-4
    Proven triple quadrupole technology and MS/MS operation principles
  3. Spec p. 5
    Accurate sulfur and sulfur isotope analysis capabilities
  4. Overview p. 6
    How MS/MS eliminates spectral interferences
  5. Overview p. 7
    Powerful, flexible and intuitive ICP-MS software features
  6. Overview p. 8
    Single cell and nanoparticle analysis extension capabilities
  7. Overview p. 9
    Proven speciation capability for elemental species
  8. Config p. 10
    Available options and accessories for the system
  9. Services p. 11
    Agilent CrossLab service and support offerings

Engineering Facts

13 facts · every claim linked to a page
Selection

UHMI is standard on the Standard and Advanced Applications configurations, so high-matrix samples up to 25% TDS can be run routinely without matrix suppression.

Determines whether the chosen configuration can handle high-TDS samples without a dilution step.

Source
“UHMI increases matrix tolerance up to 25% total dissolved solids (TDS).”
Selection

Only the Advanced Applications and Semiconductor configurations add the fifth gas controller and low Si/S argon path needed for ultratrace Si and S work.

Affects configuration choice if ppt-level Si and S analysis is required.

Source
“Advanced and Semiconductor configurations include 5th (option) gas controller and low Si/S argon flow path.”
Performance

Q1 runs at 0.7 u resolution in MS/MS to reject all off-mass ions before the cell, which is the basis of controlled reaction chemistry.

Explains the interference-removal mechanism the method design relies on.

Source
“Q1 operates at 0.7 u resolution, rejecting all masses except the target analyte mass”
Performance

The vacuum system must let Q1 reach sub-1 u resolution, so vacuum performance directly gates MS/MS capability.

Links vacuum system condition to the ability to run MS/MS methods.

Source
“ensuring that Q1 achieves the <1 u resolution capability needed for MS/MS”
Operation

The detector supports a 0.1 ms minimum dwell time, enabling fast-transient analysis for single nanoparticles, single cells, and laser ablation.

Confirms suitability for transient signals when specifying the detector and acquisition setup.

Source
“Short (0.1 ms) minimum dwell time supports fast-transient signal analysis”
Maintenance

The ion lens sits outside the high-vacuum region, so routine lens access does not require breaking vacuum.

Reduces maintenance downtime and simplifies service planning.

Source
“The ion lens is located outside the high vacuum region, making it easy to access for routine maintenance.”
Maintenance

Interface cones are screw-threaded for easy removal during routine maintenance.

Simplifies the most frequent user maintenance task on the interface.

Source
“Screw-threaded for easy removal during routine maintenance.”
Installation

The torch auto-aligns after routine maintenance, reducing the need for manual realignment.

Affects installation and service workflow after torch cleaning or replacement.

Source
“Torch auto-aligns following routine maintenance.”
Selection

The optional AVS MS valve system enables discrete sampling at under one minute per sample.

Relevant when throughput requirements drive accessory selection.

Source
“fast analysis of less than 1 minute per sample with discrete sampling”
Compliance

The SEMI S2 kit adds an Emergency Off button for the 8900 Semiconductor configuration to meet SEMI S2 guidelines together with lab safety measures.

Required for semiconductor fabs where SEMI S2 compliance is mandatory.

Source
“Includes an Emergency Off button for the 8900 Semiconductor ICP-QQQ.”
Selection

The inert sample introduction kit is O-ring free and made from PFA for low contamination and HF resistance.

Determines the sample path materials needed for HF-containing or high-purity samples.

Source
“Inert sample introduction kit is O-ring free, and manufactured from PFA for low contamination levels.”
Operation

Laser ablation control supports imaging acquisitions longer than 24 hours.

Sets expectations for long unattended LA-ICP-MS imaging runs.

Source
“including imaging applications requiring extended acquisition times (more than 24 hours)”
Selection

The I-AS autosampler is intended for ultratrace semiconductor chemical analysis and small sample volumes of 0.5 mL.

Guides autosampler choice when sample volume is limited.

Source
“Ideal for ultratrace analysis in high purity semiconductor chemicals, and for analysis of small sample volumes (0.5 mL).”