Induztr
Engineering Digest Document Viewer Related Models

Development of a Rapid 2-AB Sample Preparation Workflow for N-Glycans

Technical Reference Summary

Covered Models & Document Scope

Application note comparing Agilent GlykoPrep with 2-AB and Agilent AdvanceBio Gly-X N-Glycan Prep with 2-AB Express workflows for N-glycan sample preparation and HILIC-UHPLC analysis; no instrument models or ordering codes covered.

Technical Data

Parameter Value Condition
Denature time (GlykoPrep with 2-AB) 5 min p.2 ↗ GlykoPrep with 2-AB
Deglycosylation time (GlykoPrep with 2-AB) 15 to 60 min p.2 ↗ GlykoPrep with 2-AB
Dry down time (GlykoPrep with 2-AB) 30 to 60 min p.2 ↗ GlykoPrep with 2-AB
Labeling time (GlykoPrep with 2-AB) 60 min p.2 ↗ GlykoPrep with 2-AB
Cleanup time (GlykoPrep with 2-AB) 15 to 30 min p.2 ↗ GlykoPrep with 2-AB, solid phase, vacuum driven
Total workflow time (GlykoPrep with 2-AB) ~3.5 hours p.2 ↗ GlykoPrep with 2-AB
Denature time (Gly-X with 2-AB Express) 3 min p.2 ↗ AdvanceBio Gly-X with 2-AB Express
Deglycosylation time (Gly-X with 2-AB Express) 5 min p.2 ↗ AdvanceBio Gly-X with 2-AB Express, in solution
Labeling time (Gly-X with 2-AB Express) 60 min p.2 ↗ AdvanceBio Gly-X with 2-AB Express, on matrix
Cleanup time (Gly-X with 2-AB Express) 10 to 15 min p.2 ↗ AdvanceBio Gly-X with 2-AB Express, on matrix
Total workflow time (Gly-X with 2-AB Express) ~2 hours p.2 ↗ AdvanceBio Gly-X with 2-AB Express
Fluorescence detection excitation/emission 360/428 nm p.3 ↗ HILIC-UHPLC analysis

Operating Limits

  • Typical time to UHPLC analysis readiness (Gly-X with 2-AB Express): 2 hours p.2 ↗
  • Total workflow time (GlykoPrep with 2-AB): ~3.5 hours p.2 ↗