Induztr
Engineering Digest Document Viewer Related Models

Agilent sample prep solutions for environmental PFAS analysis

Technical Reference Summary

Covered Models & Document Scope

Agilent environmental PFAS sample preparation portfolio: Bond Elut PFAS WAX/Carbon S cartridges (200 mg PFAS WAX/50 mg Carbon S, 500 mg PFAS WAX/50 mg Carbon S, 200 mg PFAS WAX/10 mg Carbon S, 50 mg Carbon S/200 mg PFAS WAX), Bond Elut PFAS WAX cartridges, Bond Elut Carbon S for PFAS cartridges, Bond Elut LMS cartridges, Environmental PFAS Start-Up Kits, InfinityLab PFAS Analysis HPLC conversion kit, Captiva EMR PFAS Food; covers EPA 533, 537, 537.1, 1633, 8327, ASTM D7979, D7968, D8535-23, D8421-22 and ISO/DIS 21675:2019 workflows.

Technical Data

Parameter Value Condition
Tube purity Proprietary p.5 ↗ Bond Elut PFAS WAX/Carbon S, GC FID test
Frit purity Proprietary p.5 ↗ Bond Elut PFAS WAX/Carbon S, HPLC QQQ test
Average particle size D50 38.1-52.4 µm p.5 ↗ specification range
Average particle size D50 46.2 µm p.5 ↗ result, laser diffraction
Average pore diameter 50.0-250.0 Å p.5 ↗ specification range
Average pore diameter 157.5 Å p.5 ↗ result, nitrogen adsorption isotherm
Turbidity ≤7.0 NTU p.5 ↗ specification limit
Turbidity 0.5 NTU p.5 ↗ result, turbidity meter
Washable residue ≤1.0 mg/g p.5 ↗ specification limit
Washable residue 0.1 mg/g p.5 ↗ result, methanol and hexane gravimetric
Ion exchange capacity 0.40-0.82 meq/g p.5 ↗ specification range
Ion exchange capacity 0.63 meq/g p.5 ↗ result, counter ion titration
Cleanliness test Proprietary Pass p.5 ↗ GC FID test
Bed mass consistency Proprietary Pass p.5 ↗ weight measurement
Flow characteristics Proprietary Pass p.5 ↗ air flow test
PFAS recovery Proprietary Pass p.5 ↗ HPLC QQQ test
PFAS cleanliness Proprietary Pass p.5 ↗ HPLC QQQ test

Operating Limits

  • Turbidity specification limit: ≤7.0 NTU p.5 ↗
  • Washable residue specification limit: ≤1.0 mg/g p.5 ↗
  • Average particle size D50 specification range: 38.1-52.4 µm p.5 ↗
  • Average pore diameter specification range: 50.0-250.0 Å p.5 ↗
  • Ion exchange capacity specification range: 0.40-0.82 meq/g p.5 ↗