Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH1 2BH1330 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Side channel blower 2BH1 330 (G-BH1 series), sizes 10, 11, 12; three-phase and single-phase motors; 50 Hz and 60 Hz; voltage ranges and fixed voltages; VFD operation up to 87 Hz; ordering code 2BH1330-..□.□

Technical Data

Parameter Value Condition
Rated pressure -80 mbar p.2 ↗ 2BH1330-1AH06, 50 Hz
Max. differential pressure 70 mbar p.2 ↗ 2BH1330-1AH06, 50 Hz
Voltage 200-240 / 345-415 Y V p.2 ↗ 2BH1330-1AH06, 50 Hz
Current 1,9 / 1,1 Y A p.2 ↗ 2BH1330-1AH06, 50 Hz
Power 0,25 kW p.2 ↗ 2BH1330-1AH06, 50 Hz
Sound pressure level 51 dB(A) p.2 ↗ 2BH1330-1AH06, 50 Hz
Weight 10 kg p.2 ↗ 2BH1330-1AH06, 50 Hz
Rated pressure -90 mbar p.2 ↗ 2BH1330-1AH06, 60 Hz
Max. differential pressure 80 mbar p.2 ↗ 2BH1330-1AH06, 60 Hz
Voltage 220-275 / 380-480 Y V p.2 ↗ 2BH1330-1AH06, 60 Hz
Current 1,74 / 1,0 Y A p.2 ↗ 2BH1330-1AH06, 60 Hz
Power 0,29 kW p.2 ↗ 2BH1330-1AH06, 60 Hz
Sound pressure level 55 dB(A) p.2 ↗ 2BH1330-1AH06, 60 Hz
Weight 11 kg p.2 ↗ 2BH1330-1AH06, 60 Hz
Rated pressure -120 mbar p.2 ↗ 2BH1330-1AH16, 50 Hz
Max. differential pressure 130 mbar p.2 ↗ 2BH1330-1AH16, 50 Hz
Power 0,40 kW p.2 ↗ 2BH1330-1AH16, 50 Hz
Sound pressure level 58 dB(A) p.2 ↗ 2BH1330-1AH16, 50 Hz
Weight 11 kg p.2 ↗ 2BH1330-1AH16, 50 Hz
Rated pressure -120 mbar p.2 ↗ 2BH1330-1AH26, 50 Hz
Max. differential pressure 140 mbar p.2 ↗ 2BH1330-1AH26, 50 Hz
Power 0,70 kW p.2 ↗ 2BH1330-1AH26, 50 Hz
Sound pressure level 58 dB(A) p.2 ↗ 2BH1330-1AH26, 50 Hz
Weight 12 kg p.2 ↗ 2BH1330-1AH26, 50 Hz
Protection class IP 55 p.1 ↗ standard motors

Operating Limits

  • Max. ambient / suction temperature for performance data: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Protection class: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Voltage tolerance, three-phase fixed voltage motors: ±10 % p.2 ↗
  • Voltage tolerance, three-phase voltage range motors: ±5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1330 Series and size (side channel blower 2BH1, size 330)
field 1 p.2 ↗ 1 / 7 Motor type: 1 = three-phase, 7 = single-phase
field 2 p.2 ↗ A / V Voltage variant group (A = three-phase voltage range, V = single-phase)
field 3 p.2 ↗ H / C / P Voltage code: H = 200-240/345-415 V range, C = 500/575 V, P = fixed voltage
field 4 p.2 ↗ 1 / 3 / 5 / 6 / 7 Voltage range / fixed voltage option
field 5 p.2 ↗ □ Placeholder for motor variant / option

Related models