Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — 2BH9230 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH92300: side channel blower with integrated frequency converter (VFD), type 2BH92300. Covers 50 Hz and 60 Hz operation, vacuum and pressure operation, discharge right (standard) and discharge left (optional), and VFD types A–K.

Technical Data

Parameter Value Condition
Frequency 60 Hz p.2 ↗ 2BH92300, 60 Hz
Rated voltage 370 V p.2 ↗ 2BH92300, 60 Hz
Current 35,5 A p.2 ↗ 2BH92300, 60 Hz
Power 18,5 kW p.2 ↗ 2BH92300, 60 Hz
Max. differential pressure, vacuum -130 mbar p.2 ↗ 2BH92300, 60 Hz
Max. differential pressure, pressure 110 mbar p.2 ↗ 2BH92300, 60 Hz
Sound pressure level 81 dB(A) p.2 ↗ 2BH92300, 60 Hz
Weight 166 kg p.2 ↗ 2BH92300, 60 Hz
Frequency 60 Hz p.2 ↗ 2BH92300, 60 Hz, VFD type J
Rated voltage 370 V p.2 ↗ 2BH92300, 60 Hz, VFD type J
Current 24,5 A p.2 ↗ 2BH92300, 60 Hz, VFD type J
Max. differential pressure, vacuum -190 mbar p.2 ↗ 2BH92300, 60 Hz, VFD type J
Max. differential pressure, pressure 180 mbar p.2 ↗ 2BH92300, 60 Hz, VFD type J
Weight 178 kg p.2 ↗ 2BH92300, 60 Hz, VFD type J
Frequency 50 Hz p.2 ↗ 2BH92300, 50 Hz
Max. differential pressure, vacuum -190 mbar p.2 ↗ 2BH92300, 50 Hz
Max. differential pressure, pressure 170 mbar p.2 ↗ 2BH92300, 50 Hz
Weight 146 kg p.2 ↗ 2BH92300, 50 Hz
Frequency 60 Hz p.2 ↗ 2BH92300, 60 Hz, VFD type A
Rated voltage 265 ∆ V p.2 ↗ 2BH92300, 60 Hz, VFD type A
Current 55,5 ∆ A p.2 ↗ 2BH92300, 60 Hz, VFD type A
Power 19,9 kW p.2 ↗ 2BH92300, 60 Hz, VFD type A
Max. differential pressure, vacuum -150 mbar p.2 ↗ 2BH92300, 60 Hz, VFD type A
Max. differential pressure, pressure 130 mbar p.2 ↗ 2BH92300, 60 Hz, VFD type A
Weight 148 kg p.2 ↗ 2BH92300, 50 Hz, VFD type A

Operating Limits

  • Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve reference air temperature: 15 °C p.1 ↗
  • Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗

Type Code Decoder

Position Token Meaning
1-8 p.2 ↗ 2BH92300 Blower type / size designation
field 1 p.2 ↗ 1 Version / generation field
field 2 p.2 ↗ AA Motor / connection variant field
field 3 p.2 ↗ Pxx Placeholder for VFD type (A–K)
field 4 p.2 ↗ AA Discharge direction: AA = discharge right (standard); optional discharge left variant printed as 2BH9 2300-5AAPxx-AA
field 5 p.2 ↗ Q2 / R2 / KQ6 / KR6 Variant code of the selection table row
field 6 p.2 ↗ BA Suffix variant code

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH92300-1AA3Q2-BA p.2 ↗ 2BH92300-1AA3Q2-BA J 60 Hz, VFD type J
2BH92300-1AA3R2-BA p.2 ↗ 2BH92300-1AA3R2-BA 60 Hz
2BH92300-1AAKQ6-BA p.2 ↗ 2BH92300-1AAKQ6-BA 50 Hz footnote 3)
2BH92300-1AAKR6-BA p.2 ↗ 2BH92300-1AAKR6-BA 50 Hz footnote 3)