Technical Data Sheet — 2BH9230 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH92300: side channel blower with integrated frequency converter (VFD), type 2BH92300. Covers 50 Hz and 60 Hz operation, vacuum and pressure operation, discharge right (standard) and discharge left (optional), and VFD types A–K.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Frequency | 60 Hz p.2 ↗ | 2BH92300, 60 Hz |
| Rated voltage | 370 V p.2 ↗ | 2BH92300, 60 Hz |
| Current | 35,5 A p.2 ↗ | 2BH92300, 60 Hz |
| Power | 18,5 kW p.2 ↗ | 2BH92300, 60 Hz |
| Max. differential pressure, vacuum | -130 mbar p.2 ↗ | 2BH92300, 60 Hz |
| Max. differential pressure, pressure | 110 mbar p.2 ↗ | 2BH92300, 60 Hz |
| Sound pressure level | 81 dB(A) p.2 ↗ | 2BH92300, 60 Hz |
| Weight | 166 kg p.2 ↗ | 2BH92300, 60 Hz |
| Frequency | 60 Hz p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Rated voltage | 370 V p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Current | 24,5 A p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Max. differential pressure, vacuum | -190 mbar p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Max. differential pressure, pressure | 180 mbar p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Weight | 178 kg p.2 ↗ | 2BH92300, 60 Hz, VFD type J |
| Frequency | 50 Hz p.2 ↗ | 2BH92300, 50 Hz |
| Max. differential pressure, vacuum | -190 mbar p.2 ↗ | 2BH92300, 50 Hz |
| Max. differential pressure, pressure | 170 mbar p.2 ↗ | 2BH92300, 50 Hz |
| Weight | 146 kg p.2 ↗ | 2BH92300, 50 Hz |
| Frequency | 60 Hz p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Rated voltage | 265 ∆ V p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Current | 55,5 ∆ A p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Power | 19,9 kW p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Max. differential pressure, vacuum | -150 mbar p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Max. differential pressure, pressure | 130 mbar p.2 ↗ | 2BH92300, 60 Hz, VFD type A |
| Weight | 148 kg p.2 ↗ | 2BH92300, 50 Hz, VFD type A |
Operating Limits
- Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve reference air temperature: 15 °C p.1 ↗
- Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-8 p.2 ↗ | 2BH92300 | Blower type / size designation |
| field 1 p.2 ↗ | 1 | Version / generation field |
| field 2 p.2 ↗ | AA | Motor / connection variant field |
| field 3 p.2 ↗ | Pxx | Placeholder for VFD type (A–K) |
| field 4 p.2 ↗ | AA | Discharge direction: AA = discharge right (standard); optional discharge left variant printed as 2BH9 2300-5AAPxx-AA |
| field 5 p.2 ↗ | Q2 / R2 / KQ6 / KR6 | Variant code of the selection table row |
| field 6 p.2 ↗ | BA | Suffix variant code |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH92300-1AA3Q2-BA p.2 ↗ | 2BH92300-1AA3Q2-BA | J | 60 Hz, VFD type J | |
| 2BH92300-1AA3R2-BA p.2 ↗ | 2BH92300-1AA3R2-BA | 60 Hz | ||
| 2BH92300-1AAKQ6-BA p.2 ↗ | 2BH92300-1AAKQ6-BA | 50 Hz | footnote 3) | |
| 2BH92300-1AAKR6-BA p.2 ↗ | 2BH92300-1AAKR6-BA | 50 Hz | footnote 3) |