Technical Data Sheet — L-BL2 2BL2341 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Technical data sheet for the compact circuit vacuum pump 2BL2 341 (L-BL2 range, 'Pump in a Box'), 3~ 50/60 Hz, IP55, insulation class F, UL (E489378). Ordering codes 2BL2341-0 □ K03-1B, -0 □ K03-6B, -0 □ Q03-7B; material variants K, B, R, H.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Pumping speed | 200 m³/h p.1 ↗ | 2BL2 341, 50 Hz |
| Pumping speed | 200 m³/h p.1 ↗ | 2BL2 341, 60 Hz |
| Motor power | 7,0 kW p.2 ↗ | 2BL2 341, 50 Hz, IE3 |
| Motor power | 9,7 kW p.2 ↗ | 2BL2 341, 60 Hz, IE3 |
| Service factor | 1,57 p.2 ↗ | 2BL2 341, 50 Hz |
| Service factor | 1,30 p.2 ↗ | 2BL2 341, 60 Hz |
| Voltage | 190-210 / 380-420 V p.2 ↗ | 2BL2 341, 50 Hz, Δ/Υ |
| Voltage | 220-240 / 440-480 V p.2 ↗ | 2BL2 341, 60 Hz, Δ/Υ |
| Current | 50,0 / 25,0 A p.2 ↗ | 2BL2 341, 50 Hz, Δ/Υ |
| Current | 44,0 / 22,0 A p.2 ↗ | 2BL2 341, 60 Hz, Δ/Υ |
| Noise level | 72 dB(A) p.2 ↗ | 2BL2 341, 50 Hz |
| Noise level | 70 dB(A) p.2 ↗ | 2BL2 341, 60 Hz |
| Weight | 261 kg p.2 ↗ | 2BL2 341, 50 Hz |
| Weight | 253 kg p.2 ↗ | 2BL2 341, 60 Hz |
| Protection rating | IP55 p.2 ↗ | all variants |
| Insulation class | F p.2 ↗ | all variants |
| Intake temperature | 20 °C p.1 ↗ | characteristic curves basis |
| Suction pressure | 1013 mbar abs. p.1 ↗ | characteristic curves basis |
Operating Limits
- Protection rating: IP55 p.2 ↗
- Insulation class: F p.2 ↗
- Intake temperature (curve basis): 20 °C p.1 ↗
- Suction pressure (curve basis): 1013 mbar abs. p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BL2 | Model range L-BL2 compact circuit vacuum pump |
| 7-9 p.2 ↗ | 341 | Size designation |
| field 1 p.2 ↗ | □ | Material variant: K, B, R or H |
| field 2 p.2 ↗ | K03 / Q03 | Voltage/frequency variant code (K03 = 50/60 Hz, Q03 = 60 Hz) |
| field 3 p.2 ↗ | 1B / 6B / 7B | Voltage connection variant |