Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — L-BV7 2BV7070 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BV7 070, liquid ring vacuum pump, model range L-BV7. Covers 2BV7070-2 variants with voltage/frequency codes K00-1B, K00-6B, Q00-7B (50 Hz and 60 Hz, IE3 and NP efficiency motors).

Technical Data

Parameter Value Condition
Operating principle Liquid ring vacuum pump p.1 ↗ 2BV7 070
Ultimate pressure 33 mbar abs. p.1 ↗ 97 % vacuum
Cavitation-free operation down to 80 mbar abs. p.1 ↗
Pumping speed 68 m³/h p.2 ↗ 2BV7070, 50 Hz, 2.4 kW
Pumping speed 74 m³/h p.2 ↗ 2BV7070, 50 Hz, 3.5 kW
Motor power 2,4 kW p.2 ↗ 50 Hz, IE3
Motor power 3,5 kW p.2 ↗ 50 Hz, IE3/NP
Service factor 1,67 p.2 ↗ 2.4 kW
Service factor 1,30 p.2 ↗ 3.5 kW IE3
Service factor 1,15 p.2 ↗ 3.5 kW NP
Voltage 190-210 V p.2 ↗ 50 Hz, Δ
Voltage 380-420 V p.2 ↗ 50 Hz, Y
Voltage 220-240 V p.2 ↗ 50 Hz, Δ
Voltage 440-480 V p.2 ↗ 50 Hz, Y
Current 16,5 A p.2 ↗ 190-210 V Δ, 2.4 kW
Current 9,3 A p.2 ↗ 380-420 V Y, 3.5 kW
Current 14,3 A p.2 ↗ 220-240 V Δ, 2.4 kW
Current 8,3 A p.2 ↗ 380-420 V Y, 2.4 kW
Sound pressure level 68 dB(A) p.2 ↗ 2.4 kW
Sound pressure level 74 dB(A) p.2 ↗ 3.5 kW
Weight 39 kg p.2 ↗ 2.4 kW
Weight 74 kg p.2 ↗ 3.5 kW
Protection rating IP55 p.1 ↗
Insulation class F p.2 ↗
Max. back pressure 1300 mbar atm. p.2 ↗ 50 Hz and 60 Hz

Operating Limits

  • Min. inlet pressure (ultimate): 33 mbar abs. p.1 ↗
  • Cavitation-free operation down to: 80 mbar abs. p.1 ↗
  • Max. back pressure: 1300 mbar atm. p.2 ↗
  • Max. water carry-over (50 Hz): 0,7 m³/h p.2 ↗
  • Max. water carry-over (60 Hz): 0,85 m³/h p.2 ↗
  • Protection rating: IP55 p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BV7 Model range L-BV7 liquid ring vacuum pump
5-8 p.2 ↗ 070 Size 070
9-10 p.2 ↗ -2 Variant 2
field 1 p.2 ↗ K / Q Voltage/frequency code: K = 50/60 Hz standard ranges, Q = 475-525 V / 550-600 V
field 2 p.2 ↗ 1 / 6 / 7 Voltage connection variant (1 = 190-210 V Δ / 380-420 V Y; 6 = 220-240 V Δ / 440-480 V Y; 7 = 380-420 V Δ / 660-725 V Y)
field 3 p.2 ↗ B Version suffix