Operating Instructions — VGD 10 vacuum pump (BA 230-EN, ed. 2.0 22/06/2022, EN)
Technical Reference Summary
Covered Models & Document Scope
This document covers the oil-flooded rotary vane vacuum pumps V-VGD 10 and V-VGD 15 (V Series, Edition 2.0, BA 230-EN). It describes the machine as a pump and motor combination ready for connection, with variants for fine vacuum (2 to 200 mbar abs.) and rough vacuum (10 to 600 mbar abs.) set via an adjusting bolt. Optional accessories mentioned include a gas ballast valve and a plug connection for the motor.
Section-by-Section Technical Breakdown
The V-VGD machines are one-step, oil-flooded rotary vane vacuum pumps. The rotor blades on the motor shaft divide the pump housing into chambers whose volumes change periodically; oil seals the gap, lubricates and dissipates compression heat. The pump has an integrated mesh filter on the suction side, an oil and oil mist separator on the outlet side, a motor fan cooling the oil and housing, and an integral non-return valve. The data plate encodes model/size, serial number, year of construction, data matrix barcode, article number, pumping capacity, speed, motor output, operating mode and final pressure for 50/60 Hz.
- One-step oil-flooded rotary vane design with integrated suction mesh filter and outlet oil/oil-mist separator.
- Integral non-return valve prevents the evacuated system from being ventilated after the pump stops.
- Optional gas ballast valve (accessories) prevents condensation of small water vapour quantities at operating temperature.
- Data plate fields: model/size, serial number, year of construction, data matrix barcode, article No., pumping capacity 50/60 Hz, speed 50/60 Hz, motor output 50/60 Hz, operating mode, final pressure (abs.) 50/60 Hz.
- Barcode encodes material number (MA), production order (PR) and serial number (SC).
The pumps generate vacuum with nominal pumping capacities of 10 m³/h (VGD 10) and 15 m³/h (VGD 15) at 50 Hz free intake. The user can select fine vacuum (max. final vacuum 2 mbar abs.) or rough vacuum (max. final vacuum 10 mbar abs.). Continuous operation is permitted only within the intake pressure ranges 2 to 200 mbar (abs.) for fine vacuum and 10 to 600 mbar (abs.) for rough vacuum; outside these ranges oil may leak through the outlet. When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity.
- Nominal pumping capacity at 50 Hz free intake: 10 m³/h (VGD 10), 15 m³/h (VGD 15).
- Fine vacuum: max. final vacuum 2 mbar (abs.); continuous range 2 to 200 mbar (abs.).
- Rough vacuum: max. final vacuum 10 mbar (abs.); continuous range 10 to 600 mbar (abs.).
- Closed-system evacuation volume must be ≤ 2% of nominal pumping capacity.
- Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits; contact manufacturer.
- Outdoor installation requires protection from environmental influences (e.g. protective roof).
Installation requires free access from all sides, unobstructed ventilation grids, no external vibrations, and no intake of hot exhaust air from other machines into the cooling system. The machine must be set up horizontally with a maximum inclination of 1° in all directions, secured against tipping, and placed on a level floor able to carry its weight. Cooling air inlets and outlets must be at least 30 cm from adjacent walls, and at least 30 cm space must be provided around the machine for maintenance. The non-return valve must not be removed.
- Maximum inclination: 1° in all directions; machine must be secured against tipping and falling.
- Cooling air inlets/outlets at least 30 cm from adjacent walls; cooling air must not be recirculated.
- Provide at least 30 cm space around the machine for maintenance.
- Ambient temperature for operation: min. +12 °C, max. +40 °C.
- Output reduction occurs above 1000 m above sea level; contact manufacturer.
- Installation on a firm base without anchoring is possible; flexible buffers recommended on a substructure.
The exhaust air opening must not be closed or restricted, and no filter may be installed on the exhaust air side. Counter pressure on the exhaust side is permissible only up to +100 mbar. Liquids must not accumulate in the exhaust line. Pipes must be screwed in by hand only; flexible connections should be used if necessary. For standstill times longer than two minutes, the inlet line should be vented to atmospheric pressure. For parallel operation of multiple pumps, an external non-return valve must be installed in the inlet line upstream of each pump.
- Maximum permissible back pressure on exhaust side: +100 mbar.
- No filter may be installed on the exhaust air side; exhaust opening must not be closed or restricted.
- Remove blind plugs at suction connection and exhaust air outlet before connecting pipes.
- Screw in pipes by hand only; use flexible connections if necessary.
- Provide an air release position (e.g. ball valve) in the inlet line for standstill > 2 minutes.
- Parallel operation requires an external non-return valve in the inlet line upstream of each pump.
- Undersized or too-long inlet pipe reduces suction capacity.
The lubricating oil level is checked through the oil sight glass and topped up via the oil filling point to the upper edge of the sight glass. The motor must be connected by a qualified electrician observing EN 60204, with a main switch and motor protection switch installed by the operating company. Motors comply with DIN EN 60034, protection class IP 55 and insulation class F. Permissible tolerances are ±5% voltage deviation and ±2% frequency deviation. The direction of rotation must match the arrow on the motor flange.
- Oil filled up to the upper edge of the oil sight glass.
- Electrical installation per EN 60204 by qualified electrician; main switch and motor protection switch by operating company.
- Motor protection class IP 55, insulation class F, per DIN EN 60034.
- Permissible voltage deviation: ±5% of nominal value; frequency deviation: ±2%.
- Direction of rotation must match rotation direction arrow on motor flange.
- Motor protection circuit breakers with delayed switch off recommended due to temporary excess current at cold start.
Before start-up, an installation check must confirm no transport damage, safe horizontal standing, correct and leak-tight pipe connections, tight screw and flange connections, compliant electrical installation, adequate room ventilation, correct oil level, and clean pump and pipelines. The direction of rotation is checked by briefly starting the motor (max. two seconds); when looking at the motor blower it must rotate counter-clockwise. The operating range is set with the adjusting bolt: fine vacuum with the slot horizontal (turn clockwise to end position), rough vacuum with the slot vertical (turn counter-clockwise). Oil level must be checked at least once daily.
- Brief motor start max. two seconds to check rotation direction; motor blower must rotate counter-clockwise.
- After correcting rotation direction, run 2 minutes and top up oil to upper edge of sight glass until all oil pipes are filled.
- Fine vacuum setting: adjusting bolt slot horizontal, turned clockwise to end position; range 2 to 200 mbar (abs.).
- Rough vacuum setting: adjusting bolt slot vertical, turned counter-clockwise; range 10 to 600 mbar (abs.).
- Oil level checked at least once daily; refill with machine switched off and bled to atmospheric pressure.
- For standstill > 2 minutes, vent the connected inlet line to atmospheric pressure.
Maintenance covers ensuring operational safety, a maintenance table, preparation for maintenance works, cleaning the vacuum pump, cleaning the air filter, lubricating oil (refilling and oil change), the oil separator element, the motor, repair/service and spare parts. The lubricating oil must comply with ISO VG 100 as per DIN ISO 3448. The oil separator element must be changed when dirty. Repairs are only allowed by authorised workshops using original spare parts.
- Lubricating oil viscosity must comply with ISO VG 100 as per DIN ISO 3448.
- Oil separator element must be changed when dirty.
- Air filter (intake filter) must be cleaned or replaced when dirty.
- Ventilation slots must be cleaned to maintain cooling.
- Repairs only by manufacturer or authorised workshop using original spare parts.
The manual contains a table of malfunctions listing symptom, cause, elimination and reference note. Symptoms include machine switched off by motor protection switch, insufficient pumping capacity, final pressure not reached, machine overheating, visible oil mist in exhaust air, strange noise, and water in lubricating oil. The manual warns that a pump switched off automatically must not be restarted without determining and remedying the cause.
- Never restart a pump after automatic shut-off without finding and remedying the cause.
- Motor protection switch may trip due to incorrect mains voltage/frequency, incorrect terminal board connection, incorrect switch setting, cold oil, viscous oil, dirty oil separator, or high back pressure.
- Insufficient pumping capacity may be caused by long/narrow inlet pipe, leaks, or dirty intake filter.
- Final pressure not reached may be caused by leaks, incorrect oil viscosity, or incorrect adjusting bolt setting.
- Overheating may be caused by high ambient/inlet temperature, obstructed cooling air, viscous oil, dirty oil separator, or high back pressure.
- Visible oil mist may be caused by incorrectly inserted oil separator elements, missing O-rings, unsuitable oil, dirty separator, high temperatures, or obstructed cooling air.
- Strange noise may be caused by worn pump housing, damaged blades, cold oil, or viscous oil; blade hammering when starting cold is normal if it disappears within two minutes.
- Water in lubricating oil may be caused by water ingress, excessive water vapour, or short operating time; remedies include water interceptor, increased gas ballast, or running with closed suction side until water evaporates.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Nominal pumping capacity at 50 Hz free intake is 10 m³/h for V-VGD 10 and 15 m³/h for V-VGD 15. p.16 ↗ | Use these values for sizing the vacuum system at 50 Hz; refer to data sheet D 230 for capacity vs. intake pressure. | V-VGD 10 and V-VGD 15 |
| Fine vacuum continuous operating range is 2 to 200 mbar (abs.); rough vacuum continuous operating range is 10 to 600 mbar (abs.). p.16 ↗ | Continuous operation outside these ranges risks oil leakage through the outlet opening. | V-VGD 10 and V-VGD 15 |
| Maximum final vacuum is 2 mbar (abs.) in fine vacuum mode and 10 mbar (abs.) in rough vacuum mode. p.16 ↗ | Select the adjusting bolt setting according to the required ultimate pressure. | V-VGD 10 and V-VGD 15 |
| When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity. p.16 ↗ | Size the evacuated volume accordingly to avoid operating outside the intended use. | V-VGD 10 and V-VGD 15 |
| Permissible ambient and inlet temperature range is 5 to 40 °C. p.8 ↗ | Temperatures outside this range require consultation with the manufacturer. | V-VGD 10 and V-VGD 15 |
| Maximum permissible back pressure on the exhaust side is +100 mbar. p.8 ↗ | Exhaust lines must be sized and routed to avoid exceeding this limit; no filter may be installed on the exhaust side. | V-VGD 10 and V-VGD 15 |
| Maximum installation inclination is 1° in all directions; machine must be set up horizontally. p.17 ↗ | Mounting surface must be level and able to carry the machine weight; secure against tipping. | V-VGD 10 and V-VGD 15 |
| Cooling air inlets and outlets must be at least 30 cm from adjacent walls; at least 30 cm space around the machine for maintenance. p.17 ↗ | Plan installation clearances to ensure adequate cooling and service access. | V-VGD 10 and V-VGD 15 |
| Ambient temperature for operation at installation: min. +12 °C, max. +40 °C. p.17 ↗ | Ensure room ventilation and heating/cooling to keep within this range. | V-VGD 10 and V-VGD 15 |
| Output reduction occurs when installed at more than 1000 m above sea level. p.17 ↗ | Contact manufacturer for high-altitude installations. | V-VGD 10 and V-VGD 15 |
| Motor electrical tolerances: ±5% voltage deviation and ±2% frequency deviation from nominal. p.19 ↗ | Verify mains supply quality before connection; motor data must match installation location. | V-VGD 10 and V-VGD 15 |
| Motor protection class IP 55, insulation class F, compliant with DIN EN 60034. p.19 ↗ | Suitable for dusty/damp industrial environments within IP55 limits; electrical installation per EN 60204. | V-VGD 10 and V-VGD 15 |
| Lubricating oil viscosity must comply with ISO VG 100 as per DIN ISO 3448. p.26 ↗ | Use only oil of this viscosity grade; incorrect viscosity can cause overheating, insufficient pumping capacity or noise. | V-VGD 10 and V-VGD 15 |
| Oil level must be checked at least once daily through the oil sight glass. p.22 ↗ | Low oil level can damage the vacuum pump; refill with machine off and bled to atmospheric pressure. | V-VGD 10 and V-VGD 15 |
| For standstill times longer than two minutes, vent the connected inlet line to atmospheric pressure. p.18 ↗ | Provide an air release position (e.g. ball valve) in the inlet line to avoid machine damage. | V-VGD 10 and V-VGD 15 |
| For parallel operation of multiple pumps, an external non-return valve must be installed in the inlet line upstream of each pump. p.18 ↗ | Prevents a switched-off pump from being damaged by the suction capacity of operating pumps. | V-VGD 10 and V-VGD 15 |
| Direction of rotation check: start motor briefly (max. two seconds); when looking at the motor blower, it must rotate counter-clockwise. p.21 ↗ | Wrong direction of rotation for a longer time may damage the machine. | V-VGD 10 and V-VGD 15 |
| Fine vacuum setting: adjusting bolt slot horizontal, turned clockwise to end position. Rough vacuum setting: slot vertical, turned counter-clockwise. p.21 ↗ | Set operating range according to required vacuum level before commissioning. | V-VGD 10 and V-VGD 15 |
| Storage temperature range: -10 °C to +60 °C; relative air humidity max. 80%; storage not more than 6 months. p.13 ↗ | For long-term storage (>3 months), use preservation oil rather than operating oil. | V-VGD 10 and V-VGD 15 |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Machine is switched off by the motor protection switch p.30 ↗ | Mains voltage/ Frequency does not correspond with the motor data | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.30 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.30 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.30 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per IEC 60947-4-1) | |
| Machine is switched off by the motor protection switch p.30 ↗ | Vacuum pump or its oil is too cold | Note the ambient temperature and the inlet temperature | Chapter 2.4 |
| Machine is switched off by the motor protection switch p.30 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Machine is switched off by the motor protection switch p.30 ↗ | The oil separator element is dirty. | Change the oil separator element | Chapter 7.7 |
| Machine is switched off by the motor protection switch p.30 ↗ | The back pressure in the exhaust line is too high | Check the hose and/or the pipe | Chapter 5.3 |
| Pumping capacity is insufficient p.30 ↗ | The inlet pipe is too long or too narrow | Check the hose and/or the pipe | Chapter 5.3 |
| Pumping capacity is insufficient p.30 ↗ | Leak on the inlet side of the vacuum pump or in the system | Check the pipework and screw connections for leaks and check for tight fit | Chapter 7.2 |
| Pumping capacity is insufficient p.30 ↗ | The intake filter is dirty | Clean or replace the intake filter | Chapter 7.5 |
| Final pressure (max. vacuum) is not reached p.31 ↗ | Leak on the inlet side of the vacuum pump or in the system | Check the pipework and screw connections for leaks and check for tight fit | Chapter 7.2 |
| Final pressure (max. vacuum) is not reached p.31 ↗ | Incorrect oil viscosity | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Final pressure (max. vacuum) is not reached p.31 ↗ | The adjusting bolt is not adjusted correctly | Correct setting of operating range | Chapter 6.1.3 |
| Machine gets too hot p.31 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Machine gets too hot p.31 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Machine gets too hot p.31 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.4 |
| Machine gets too hot p.31 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Machine gets too hot p.31 ↗ | The oil separator element is dirty. | Change the oil separator element | Chapter 7.7 |
| Machine gets too hot p.31 ↗ | The back pressure in the exhaust line is too high | Check the hose and/or the pipe | Chapter 5.3 |
| Exhaust air contains visible oil mist p.31 ↗ | The oil separator elements are not inserted correctly or the O-rings are missing | Check that it is correctly seated | Chapter 7.7 |
| Exhaust air contains visible oil mist p.31 ↗ | Unsuitable oil is being used | Use suitable types | Chapter 7.6 |
| Exhaust air contains visible oil mist p.31 ↗ | The oil separator element is dirty. | Change the oil separator element | Chapter 7.7 |
| Exhaust air contains visible oil mist p.31 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Exhaust air contains visible oil mist p.31 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Exhaust air contains visible oil mist p.31 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.2 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.31 ↗ | The pump housing is worn (chatter marks) | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.31 ↗ | Blades are damaged | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.31 ↗ | Vacuum pump or its oil is too cold | Note the ambient temperature and the inlet temperature | Chapter 2.4 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.31 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Water in lubricating oil p.32 ↗ | Pump sucks in water | Install water interceptor upstream of the pump | — |
| Water in lubricating oil p.32 ↗ | The pump sucks in more water vapour than is suitable for its water vapour compatibility | Contact the manufacturer for increased gas ballast | — |
| Water in lubricating oil p.32 ↗ | Pump only works for a short time and therefore does not reach its normal operating temperature | Let the pump continue to run with a closed suction side after extracting the water vapour until the water has evaporated from the oil | — |