Operating Instructions — compressor (BA 361-EN, ed. 1.1 09/08/2023, EN)

Technical Reference Summary

Covered Models & Document Scope

Covers the dry-running rotary vane compressors V-DTR 100 and V-DTR 140 (V Series), edition 1.1, 09/08/2023, document BA 361-EN. Data plate example shows V-DTR 140 with 50/60 Hz data; nominal flow rates 100 m³/h (DTR 100) and 140 m³/h (DTR 140) at 50 Hz.

Section-by-Section Technical Breakdown

pp. 14-15
Product Overview and Description

The V-DTR machines are single-stage, dry-running rotary vane compressors. An eccentrically mounted rotor with rotary vanes divides the compression housing into chambers of periodically changing volume. The compressor is driven by a standard flanged three-phase motor via a coupling and includes a pressure regulating valve, fine micro intake filter, integral pressure-side filter for carbon dust, noise-reducing plastic cover and fan cooling.

  • Components: A air intake, B pressure connection, D pressure regulating valve, E cooling air inlet, F cooling air outlet, G cover, G1 ventilation grid, M greasing plate, N data plate, O rotation direction plate, P drive motor, Q hot surfaces >70°C, S filter housing, W maintenance plate.
  • Connecting thread on pressure side; protective cap on suction side.
  • Aspirated air cleaned by inbuilt fine micro filter; carbon dust from vane scoring separated by integral filter on pressure side.
  • Compressed air additionally cooled by a cooling segment.
  • Pressure regulating valve sets pressure to required values with an upper limit.
pp. 16
Fields of Application

The V-DTR compressors generate excess pressure between 0 and the value stated on the data plate. Continuous operation is permissible. They convey air with 30 to 90% relative humidity. Nominal flow rate is 100 m³/h (DTR 100) and 140 m³/h (DTR 140) at 50 Hz; load limits are on the data plate and flow-rate dependency on pressure is given in data sheet D361.

  • Excess pressure range: 0 to data-plate value (bar).
  • Continuous operation permissible.
  • Relative humidity of conveyed air: 30 to 90%.
  • Nominal flow: 100 m³/h (DTR 100), 140 m³/h (DTR 140) at 50 Hz.
  • Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits; contact manufacturer.
  • Observe motor protection class on data plate; protect outdoor installation (e.g. protective roof).
pp. 17-18
Installation Preparation and Mounting

Installation requires free access from all sides, unobstructed ventilation grid and holes, sufficient space for pipes and maintenance (at least 40 cm around the machine), no external vibrations, no intake of hot exhaust air from other machines, and good room ventilation. The machine must be set up horizontally with max. 10° inclination in all directions, secured against tipping/falling, on a level floor able to carry its weight.

  • Maintenance clearance: at least 40 cm around the machine.
  • Max. inclination: 10° in all directions.
  • Ambient temperature: min. +5°C, max. +40°C.
  • Cooling air inlets/outlets at least 10 cm from adjacent walls; cooling air must not be recirculated.
  • Output reduction noticeable above 1000 m above sea level; contact manufacturer.
  • Installation on firm base without anchoring possible; flexible buffers recommended on substructure.
pp. 18
Pipe Connection

Pipes must be screwed in by hand only; flexible connections should be used if necessary. For connection pipes with the same cross-section as the machine connection and more than 3 m length, a non-return valve (accessory ZRK) is recommended to avoid reverse running after stop. For parallel operation of multiple machines, an external non-return valve must be installed in the inlet line upstream of each machine.

  • Only screw in pipes by hand.
  • Use flexible connections if necessary.
  • Non-return valve ZRK recommended for pipes >3 m with same cross-section.
  • External non-return valve required in inlet line upstream of each machine for parallel operation.
  • Remove blind plug on outlet connection before connecting pipes.
  • Too narrow and/or too long outlet line reduces flow rate.
pp. 18
Pressure Control Valve

Compressors are equipped as standard with a pressure control valve. Required pressure ranges are adjusted using the valve in accordance with the symbol plate on the rotary knob. Exceeding the permissible final compression pressure stated on the data plate can damage the compressor; operation without the standard control valve does not comply with intended use.

  • Standard equipment: pressure control valve.
  • Adjust pressure range per symbol plate on rotary knob.
  • Do not exceed permissible final compression pressure from data plate.
  • Operation without standard control valve is not intended use.
pp. 19
Motor Connection

Electrical installation must be carried out by a qualified electrician observing EN 60204. The operating company must install the main switch and a motor protection switch. Motor data must match the mains; motors comply with DIN EN 60034, protection class IP 55 and insulation class F. Permissible tolerances are +5% voltage deviation and ±2% frequency deviation.

  • Electrical installation per EN 60204 by qualified electrician.
  • Main switch and motor protection switch installed by operating company.
  • Motor protection: IP 55, insulation class F, DIN EN 60034.
  • Voltage tolerance: +5% of nominal; frequency tolerance: ±2%.
  • Direction of rotation must match arrow on motor flange.
  • Motor protection circuit breakers with delayed switch off recommended due to cold-start excess current.
pp. 20-21
Start-up and Rotation Direction Check

Before start-up, verify installation: no transport/assembly damage, horizontal secure stand, correct and leak-tight pipe connections, tight screw/flange connections, electrical installation per diagram, adequate room ventilation, cleaned compressor and pipelines, and function of optional accessories. Check rotation direction with a phase sequence indicator; intended direction is anti-clockwise. Briefly start motor (max. two seconds) with outlet line disconnected; motor fan must rotate clockwise.

  • Installation check before first start-up.
  • Use phase sequence indicator; intended direction anti-clockwise.
  • Brief start max. two seconds with outlet line disconnected.
  • Motor fan must rotate clockwise when viewed at fan.
  • Long reverse running can damage or break vanes.
pp. 20-21
Operation

During operation keep sufficient distance from the compressor and pressure control valve because if the pressure control valve responds, compressed air can escape at >70°C. Hot surfaces above 70°C are marked with warning plates and must not be touched. High sound pressure levels require ear protection during long stays near the running machine.

  • Hot exhaust air >70°C possible at pressure control valve.
  • Surface temperatures above 70°C on marked components.
  • Ear protection required for prolonged proximity.
  • Machine may only be switched on again after it stands still.
pp. 13, 21
Decommissioning and Storage

Decommissioning requires disconnecting from power, securing against restart, closing shut-off devices, depressurising by slowly opening pipes, removing pipes/hoses, sealing inlet and outlet stubs, inserting desiccant into the filter housing, and storing the machine. Storage conditions: dust-free, dry, vibration-free, protected from sun, -10°C to +60°C, max. 80% relative humidity, openings closed air-tight, not more than 6 months.

  • Disconnect power and secure against unexpected restart.
  • Depressurise by slowly opening pipes.
  • Seal inlet/outlet stubs with blind plugs or adhesive foil.
  • Insert desiccant into filter housing for storage.
  • Storage temperature: -10°C to +60°C; rel. humidity max. 80%.
  • Maximum storage duration: 6 months.
pp. 23
Maintenance Table

Regular maintenance ensures operational safety; cleaning intervals depend on load and pollution. The maintenance table specifies intervals for cleaning the compressor, checking pipes/screws/terminal box for leaks, cleaning regulating valve and ventilation slots, cleaning filter cartridges, lubricating the B bearing, checking/replacing vanes, replacing filter cartridges, replacing the A bearing, checking coupling wear, and motor maintenance.

  • Clean compressor depending on degree of pollution.
  • At least monthly: check pipes/screws for leaks and tight fit; check terminal box and cable inlet holes; clean regulating valve and ventilation slots/cooling ribs; clean filter cartridges.
  • 3,000 h: lubricate B bearing (side facing away from motor).
  • 3,000 h / 1,000 h: check/replace vanes.
  • 6 months: replace filter cartridges.
  • 20,000 h: replace A bearing (motor side).
  • At least once a year: check coupling wear.
  • Motor maintenance per manufacturer's instructions.
pp. 24
Lubrication

The A bearing (motor side) has lifelong lubrication and is maintenance-free; after 20,000 operating hours or 2½ years (3-shift operation) it must be replaced by a qualified professional or authorised workshop. The B bearing (side facing away from the motor) must be lubricated on the grease nipple.

  • A bearing: lifelong lubrication, maintenance-free.
  • A bearing replacement: after 20,000 h or 2½ years in 3-shift operation.
  • B bearing: lubricate via grease nipple (Fig. 4/L).
  • Grease recommendation plate on machine.
pp. 24-29
Vanes, Air Filter, Motor and Coupling

The manual covers maintenance of vanes, air filter, motor and coupling. Vanes must be checked/replaced at 3,000 h or 1,000 h depending on condition; filter cartridges replaced every 6 months; coupling wear checked at least annually; motor maintained per manufacturer's instructions. Repair/service only by authorised workshops using original spare parts.

  • Vanes: check/replace at 3,000 h / 1,000 h.
  • Filter cartridges: replace every 6 months.
  • Coupling: check for wear at least once a year.
  • Motor: maintenance, lubrication and cleaning per manufacturer's instructions.
  • Repairs only by authorised workshops with original spare parts.
pp. 15, 33
Technical Data

Technical data are provided in chapter 10 and on the data plate. The data plate example for V-DTR 140 shows final pressure +1.4/+1.2 bar, pumping capacity 130.0/155.0 m³/h, motor output 7.50/9.00 kW, speed 1465/1760 min⁻¹ for 50/60 Hz, operating mode S1 100%.

  • Data plate fields: model/size, serial number, year of construction, data matrix barcode, article number, pumping capacity 50/60 Hz, speed 50/60 Hz, motor output 50/60 Hz, operating mode, final pressure (rel.) 50/60 Hz.
  • Example V-DTR 140: final pressure +1.4/+1.2 bar; capacity 130.0/155.0 m³/h; motor 7.50/9.00 kW; speed 1465/1760 min⁻¹; S1 100%.
  • Barcode encodes material number (MA), production order (PR), serial number (SC).

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ambient and inlet temperature permitted range: 5 to 40°C. p.8 ↗ Operation outside this range requires consultation with manufacturer; ensure installation room ventilation and cooling air supply. V-DTR 100 | 140
Conveyed air relative humidity must be 30 to 90%. p.8 ↗ Verify process air humidity before selection; outside range may affect operation and requires manufacturer contact. V-DTR 100 | 140
Back pressure on outlet side must not exceed +0.1 mbar. p.8 ↗ Ensure outlet piping and system do not impose higher back pressure; otherwise inadmissible operating mode. V-DTR 100 | 140
Maximum inclination during installation: 10° in all directions; machine must be horizontal. p.17 ↗ Mount on level floor; secure against tipping and falling. V-DTR 100 | 140
Maintenance clearance: at least 40 cm around the machine. p.17 ↗ Plan installation layout to allow pipe installation/removal and maintenance access. V-DTR 100 | 140
Cooling air inlets and outlets must be at least 10 cm from adjacent walls; cooling air must not be recirculated. p.17 ↗ Prevent overheating by ensuring unobstructed airflow and separation of exhaust air. V-DTR 100 | 140
Output reduction noticeable when installed above 1000 m above sea level. p.18 ↗ For high-altitude installations contact manufacturer for suitability and sizing. V-DTR 100 | 140
Non-return valve (accessory ZRK) recommended for connection pipes with same cross-section as machine connection and more than 3 m length. p.18 ↗ Prevents reverse running after machine stop, which can damage compressor. V-DTR 100 | 140
For parallel operation of multiple machines, an external non-return valve must be installed in the inlet line upstream of each machine. p.18 ↗ Prevents a switched-off machine from being driven by suction of operating machines. V-DTR 100 | 140
Motor electrical data: DIN EN 60034, protection class IP 55, insulation class F; voltage tolerance +5%, frequency tolerance ±2%. p.19 ↗ Verify mains voltage and frequency within tolerances; use appropriate motor protection switch. V-DTR 100 | 140
Intended direction of rotation is anti-clockwise; motor fan must rotate clockwise when viewed at fan. p.20 ↗ Check with phase sequence indicator; long reverse running can damage or break vanes. V-DTR 100 | 140
Brief start for rotation check: max. two seconds with outlet line disconnected. p.21 ↗ Prevents damage during direction verification. V-DTR 100 | 140
Storage temperature: -10°C to +60°C; relative humidity max. 80%; maximum storage duration 6 months. p.13 ↗ Store dust-free, dry, vibration-free, protected from sun; close openings air-tight. V-DTR 100 | 140
A bearing (motor side) replacement interval: 20,000 operating hours or 2½ years in 3-shift operation. p.24 ↗ Plan bearing replacement by qualified professional or authorised workshop. V-DTR 100 | 140
B bearing (side facing away from motor) lubrication interval: 3,000 h. p.23 ↗ Lubricate via grease nipple per maintenance table. V-DTR 100 | 140
Vane check/replacement interval: 3,000 h / 1,000 h. p.23 ↗ Inspect vanes for wear/damage; replace as needed to maintain performance. V-DTR 100 | 140
Filter cartridge replacement interval: 6 months. p.23 ↗ Replace filter cartridges regularly to avoid insufficient blowing capacity and overheating. V-DTR 100 | 140
Coupling wear check: at least once a year. p.23 ↗ Inspect coupling for wear to prevent drive failure. V-DTR 100 | 140
Nominal flow rate: 100 m³/h (DTR 100) and 140 m³/h (DTR 140) at 50 Hz. p.16 ↗ Use for sizing; actual flow depends on excess pressure per data sheet D361. V-DTR 100 | 140
Data plate example V-DTR 140: final pressure +1.4/+1.2 bar, capacity 130.0/155.0 m³/h, motor 7.50/9.00 kW, speed 1465/1760 min⁻¹ at 50/60 Hz, S1 100%. p.15 ↗ Verify actual data plate on delivered unit for specific model and voltage/frequency. V-DTR 140

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.30 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.30 ↗ Connection to motor terminal board is not correct Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.30 ↗ Motor protection switch is not set correctly Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.30 ↗ Motor protection switch is triggered too quickly Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per IEC 60947-4-1)
Machine is switched off by the motor protection switch p.30 ↗ The blow out filter cartridge is dirty. Clean or replace the filter cartridges Chapter 7.2.3, Chapter 7.4
Machine is switched off by the motor protection switch p.30 ↗ The regulating valve is dirty so that the permissible pressure value is exceeded. Clean or replace the regulating valve Chapter 7.2, Chapter 7.4
Blowing capacity is insufficient p.30 ↗ Intake filter and/or blow out filter are dirty Clean or replace the intake filter Chapter 7.2.3, Chapter 7.4
Blowing capacity is insufficient p.30 ↗ The pressure line is too long or too narrow Check the hose or the pipe Chapter 5.3
Blowing capacity is insufficient p.30 ↗ Machine or system leaking Check the pipework and screw connections for leaks and to ensure that they are firmly seated. Chapter 7.2
Blowing capacity is insufficient p.30 ↗ Vanes are damaged Replace vanes Chapter 7.2.2, Chapter 7.4
Final pressure (max. overpressure) is not reached p.31 ↗ Machine or system leaking Check the pipework and screw connections for leaks and to ensure that they are firmly seated. Chapter 7.2
Final pressure (max. overpressure) is not reached p.31 ↗ Vanes are worn or damaged Replace vanes Chapter 7.2.2, Chapter 7.4
Final pressure (max. overpressure) is not reached p.31 ↗ Driving power selection too low Use next largest motor output Data sheet D 361
Machine gets too hot p.31 ↗ Ambient or intake temperature is too high Ensure it is being used properly Chapter 2.3
Machine gets too hot p.31 ↗ Cooling air supply is obstructed Check environmental conditions Chapter 5.1
Machine gets too hot p.31 ↗ Cooling air supply is obstructed Clean ventilation slots Chapter 7.2
Machine gets too hot p.31 ↗ The blow out filter cartridge (accessory) is dirty. Clean or replace the filter cartridges Chapter 7.2.3, Chapter 7.4
Machine gets too hot p.31 ↗ The regulating valve is dirty so that the permissible pressure value is exceeded. Clean or replace the regulating valve Chapter 7.2, Chapter 7.4
The machine makes a abnormal noise p.31 ↗ The compressor housing is worn (chatter marks) Repair by manufacturer or authorised workshop Elmo Rietschle Service
The machine makes a abnormal noise p.31 ↗ The regulating valve is vibrating Replace the valve Chapter 7.4
The machine makes a abnormal noise p.31 ↗ Vanes are damaged Replace vanes Chapter 7.2.2, Chapter 7.4