Technical Data Sheet — vacuum pump (I 200, DE)

Technical Reference Summary

Covered Models & Document Scope

V-VCA 25 and V-VCE 25 oil-flooded rotary vane vacuum pumps, 50 Hz and 60 Hz, with 3~ flange motors in versions GA IE3, UA IE3 and TA IE3

Technical Data

Parameter Value Condition
Nominal suction capacity 25 m³/h p.1 ↗ V-VCA 25, 50 Hz
Nominal suction capacity 30 m³/h p.1 ↗ V-VCA 25, 60 Hz
Nominal suction capacity 25 m³/h p.1 ↗ V-VCE 25, 50 Hz
Nominal suction capacity 30 m³/h p.1 ↗ V-VCE 25, 60 Hz
Ultimate vacuum (standard) 0,5 mbar (abs.) p.1 ↗ V-VCA 25
Ultimate vacuum (standard) 10 mbar (abs.) p.1 ↗ V-VCE 25
Average noise level 57 dB(A) p.1 ↗ V-VCA 25, 50 Hz, EN ISO 3744
Average noise level 59 dB(A) p.1 ↗ V-VCA 25, 60 Hz, EN ISO 3744
Average noise level 57 dB(A) p.1 ↗ V-VCE 25, 50 Hz, EN ISO 3744
Average noise level 59 dB(A) p.1 ↗ V-VCE 25, 60 Hz, EN ISO 3744
Max. weight without motor 22 kg p.1 ↗ V-VCA 25 / V-VCE 25
Oil capacity 1,0 l p.1 ↗ V-VCA 25 / V-VCE 25
Intake pressure range 0,5 – 130 mbar (abs.) p.1 ↗ V-VCA, 50 Hz
Intake pressure range 10 – 500 mbar (abs.) p.1 ↗ V-VCE, 50 Hz
Intake pressure range 0,5 – 100 mbar (abs.) p.1 ↗ V-VCA, 60 Hz
Intake pressure range 10 – 400 mbar (abs.) p.1 ↗ V-VCE, 60 Hz
Motor power 0,75 kW p.1 ↗ VCA GA IE3, 50 Hz
Motor voltage 230 / 400 V ± 10 % p.1 ↗ VCA GA IE3, 50 Hz
Motor speed 1420 min⁻¹ p.1 ↗ VCA GA IE3, 50 Hz
Motor current 2,82 / 1,62 A p.1 ↗ VCA GA IE3, 50 Hz
Motor power 0,9 kW p.1 ↗ VCA GA IE3, 60 Hz
Motor voltage 265 / 460 V ± 10 % p.1 ↗ VCA GA IE3, 60 Hz
Motor speed 1720 min⁻¹ p.1 ↗ VCA GA IE3, 60 Hz
Motor current 2,90 / 1,67 A p.1 ↗ VCA GA IE3, 60 Hz
Motor weight 13,5 kg p.1 ↗ VCA GA IE3

Operating Limits

  • Intake pressure range, V-VCA, 50 Hz: 0,5 – 130 mbar (abs.) p.1 ↗
  • Intake pressure range, V-VCE, 50 Hz: 10 – 500 mbar (abs.) p.1 ↗
  • Intake pressure range, V-VCA, 60 Hz: 0,5 – 100 mbar (abs.) p.1 ↗
  • Intake pressure range, V-VCE, 60 Hz: 10 – 400 mbar (abs.) p.1 ↗
  • Motor voltage tolerance: ± 10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-5 p.1 ↗ V-VCA / V-VCE Pump series: VCA = ultimate vacuum 0,5 mbar, VCE = ultimate vacuum 10 mbar
6-7 p.1 ↗ 25 Nominal size (nominal suction capacity 25 m³/h at 50 Hz)
motor version field p.1 ↗ GA 3~ motor version GA IE3, 230/400 V, 50 Hz
motor version field p.1 ↗ UA 3~ motor version UA IE3, 330|380/660 V, 50 Hz
motor version field p.1 ↗ TA 3~ motor version TA IE3, 200|400/690 V, 50 Hz