Unistat T340w HT Technical Data Sheet

Contents

  1. Overview p. 1
    Introduces the Unistat T340w HT unit and its main features
  2. Spec pp. 1-2
    Performance, temperature, pressure, and dimensional data per DIN 12876
  3. p. 2 table, 4 rows
  4. p. 1 table, 34 rows

Technical data according to DIN 12876

ParameterValue
Degree of ProtectionIP20
max. ambient temperature40 °C
min. ambient temperature5 °C
from Serial-No.:1.1/26

Unistat T340w HT — Technical data according to DIN 12876

CharacteristicValue
Order-No.1024.0031.01
Operating temperature range65...300 °C
Minimum temperature with water cooling15 °C
temperature set point / display5,7" colour Touchscreen
Resolution of display0,01 K
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
digital inputECS ONE
digital outputPOKO ONE
Alarm messageoptic, acoustic, relay
Safety classificationIII / FL
Heating power48 kW
Cooling power at 300°C20 kW
Cooling power at 200°C20 kW
Cooling power at 100°C12 kW
Circulation pump: MK pump
max. delivery200 l/min
max. delivery pressure5,5 bar
Pump connectionM38x1,5 male
max. permissible kin. viscosity50 mm²/s
Cooling water consumption at water temp. 15°C1100 l/h
Cooling water connectionG1 1/4 male
min. cooling water differential pressure1 bar
max. cooling water pressure6 bar
min. filling capacity19 l
Filling capacity expansion tank56 l
Overall dimensions WxDxH **800x1007x1607 mm
Net weight436 kg
sound pressure level +/- 4 dB(A)59 dB(A)
Power supply (3 Phase)400V 3~ 50Hz
max. current (3 Phase)80 A
Fuse (3 phase)3x80A
Pressure equipment categoryArt. 4.3 PED

** Overall dimensions WxDxH

Engineering Facts

12 facts · every claim linked to a page
Installation

The unit requires a three-phase 400 V supply with a 3x80 A fuse, so the electrical installation must be sized for 80 A per phase.

Determines the site power distribution, cable cross-section and protection device rating before ordering.

Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Installation

Three-phase devices drawing more than 63 A are delivered without cable and without plug, so the customer must provide and terminate the power cable on site.

Affects installation planning, cost and who is responsible for the mains connection.

Source
“Three-phase devices with current consumption greater than 63A --> without cable, without plug”
Installation

Cooling water must be supplied at 1 to 6 bar differential pressure with a G1 1/4 male connection, and the circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.

Dictates water quality, pipe material compatibility and the supply pressure window for the cooling water loop.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Installation

The unit is designed for cooling water intake between 5 °C and 20 °C, and if the water temperature falls below the condensation point the cooling water pipes inside the unit must be insulated.

Prevents condensation, corrosion and electrical faults when the site cooling water is colder than ambient dew point.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance

Cooling capacity is rated at 20 kW at 300 °C and 200 °C but drops to 12 kW at 100 °C, and higher cooling water temperature reduces capacity further.

Needed to verify the heat removal capability of the application at the actual process temperature and site water conditions.

Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Selection

The Unistat T340w HT has no active refrigeration system, so reaching 65 °C requires either sufficient heat loss from the application or suitable water cooling.

Prevents selecting the unit for cooling duties it cannot perform and clarifies that sub-ambient control depends on the application heat loss.

Source
“These devices do not have an active refrigeration system.”
Operation

The water exit temperature is limited to 55 °C and no steam exits when cooling at circulation temperatures above 100 °C.

Confirms safe behaviour of the cooling water circuit at high process temperatures and avoids steam-related installation measures.

Source
“Water exit temperature limited to 55°C. No steam exits on cooling with circulation temperatures over 100°C.”
Installation

Pump connections use bore shape Y (60°) per DIN 3863 with ball socket per DIN 3863 and sleeve nut per DIN 3870, so matching hoses and fittings must be ordered.

Ensures the correct mating fittings and hoses are available for leak-free connection of the M38x1.5 pump port.

Source
“Pump connections: Bore shape Y (60°) according to DIN 3863, pipework/flexible tempering hoses: Ball socket according to DIN 3863, sleeve nut according to DIN 3870.”
Compliance

Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and a combination of -5% voltage with +2% frequency is not allowed.

Defines the acceptable mains quality at the installation site and protects the unit from combined voltage/frequency excursions.

Source
“-5% voltage and +2% frequency -> not allowed!”
Safety

The unit is classified III / FL according to DIN 12876 and has adjustable overtemperature protection, which must be set for the application.

Determines the safety category for the application and the need to configure the overtemperature limit during commissioning.

Source
“With adjustable overtemperature protection according to DIN 12876.”
Installation

The unit must be installed with respect to space requirements and operates within an ambient temperature range of 5 °C to 40 °C at IP20 protection.

Affects room layout, ventilation clearances and suitability of the installation location.

Source
“Please respect space requirements. See operating conditions at www.huber-online.com”
Maintenance

Cooling water consumption is 1100 l/h at 15 °C water temperature, so the site water supply and drain must handle this flow continuously.

Sizes the cooling water supply, return and drain infrastructure and the associated operating cost.

Source
“Cooling water consumption at water temp. 15°C 1100 l/h”