Technical Reference Summary

Covered Models & Document Scope

Instruction manual for Pfeiffer Vacuum + Fab Solutions DuoVane 36 and DuoVane 70 two-stage oil-sealed rotary vane vacuum pumps. Covers four variants: Standard (DuoVane 36/70), C version (operating fluid F5, changed vane material, hose connection and dosage spindle on gas ballast valve, oiler for shaft feedthrough, leak rate ≤1×10⁻⁷ Pa m³/s), M version (magnetic coupling, leak rate ≤1×10⁻⁷ Pa m³/s), and MC version (combines C-version features with magnetic coupling). Pumping speeds: DuoVane 36 = 32 m³/h (50 Hz) / 36 m³/h (60 Hz); DuoVane 70 = 62 m³/h (50 Hz) / 70 m³/h (60 Hz).

Section-by-Section Technical Breakdown

pp. 8-12
Safety, Limits of Use, Intended Use and Misuse

Specifies installation and operating limits (protection classes, temperatures, pressures, inclination), intended use for vacuum generation only, and prohibited uses. Defines personnel qualification requirements and safety precautions.

  • Installation location: weatherproof (internal space); protection class I; pollution degree 2; overvoltage category II (IEC 61010)
  • Protection class: IP40 (single-phase motor), IP43 (three-phase motor); housing Type 1 (UL 50E)
  • Permissible inclination: ±1° longitudinal, ±2° transverse
  • Ambient temperature +12 °C to +40 °C; relative humidity max. 85%; intake temperature max. +40 °C
  • Exhaust pressure: ≥ atmospheric, ≤ 1500 hPa absolute; constant intake pressure max. 50 hPa absolute
  • Prohibited: explosive, corrosive (except C version), radioactive media, fluids, dust, sublimating media, pressure generation, Ex areas, strong magnetic/electromagnetic fields
  • For oxygen concentration ≥ 21%, only perfluorinated synthetic oils (F4, F5, A113) as operating fluid; never mineral oil
pp. 13-15
Product Description and Operating Principle

Describes the two-stage, oil-sealed rotary displacement pump design with asynchronous motor and claw coupling, gas ballast, vacuum safety valve and operating fluid functions. Identifies pump features and delivery scope.

  • Two-stage, oil-sealed rotary displacement pumps for low and medium vacuum
  • DuoVane 36: 32 m³/h at 50 Hz, 36 m³/h at 60 Hz; DuoVane 70: 62 m³/h at 50 Hz, 70 m³/h at 60 Hz
  • Integrated gas ballast supplies ambient air or inert gas to reduce condensate
  • Vacuum safety valve separates pump from chamber at standstill, vents system so oil does not migrate; valve opens with delay after switch-on
  • Motor options: three-phase with built-in thermal winding protection, or single-phase with reversible voltage range, thermal protection switch, mains switch and rubber connector
  • Scope of delivery: pump with motor, operating fluid (other than F4/F5/A113), locking caps for both flanges, centering ring, instruction manual
pp. 18-30
Installation and Electrical Connection

Covers setup with inclination limits, repositioning vacuum/exhaust flanges, vacuum and exhaust-side connections, electrical safety measures and mains connection with 6-pin or 9-pin terminal boards, motor protection setting and rotation check. Includes requirements for frequency converter and soft-start operation.

  • Surface can exceed 70 °C — provide touch protection if unrestrictedly accessible
  • Flange repositioning: WAF 5 hex key, calibrated torque wrench (tightening factor ≤ 2.5), tightening torque 5 Nm
  • Vacuum/exhaust line cross section ≥ nominal diameter of connection flange; support piping so no forces act on pump; route exhaust piping downwards
  • Exhaust line without shut-off units; exhaust pressure ≥ atmospheric, ≤ 1500 hPa abs; negative exhaust pressure not permissible; condensate separator recommended at lowest point
  • Pump has no mains switch: install mains disconnection device, MCB with interruption rating ≥ 10 kA, and RCCB
  • Three-phase motors: direct on-line starting only — never star-delta start-up circuit
  • IE2 motor: soft-start relay or frequency converter recommended; IE3 motor: soft start or frequency converter mandatory (magnetic coupling demagnetization risk)
  • Recommended mains fuse: type 'K' circuit breaker with slow tripping characteristics
  • Rotation direction (6-pin board): U1–L2, V1–L1, W1–L3 give clockwise shaft rotation viewed at motor fan (9-pin: T1–L2, T2–L1, T3–L3)
  • Motor automatically restarts after power failure or thermal standstill — secure against restart during work
pp. 31-37
Operation and Gas Ballast Use

Covers commissioning, switching on/off, operating with gas ballast (standard valve and inert-gas connection version) and refilling operating fluid. Gas ballast operation reduces condensate in the pumping system.

  • Gas ballast valve standard version and variant with inert gas connection described
  • Gas ballast supports reduction of condensate accumulating in the pumping system
  • Refill operating fluid during operation as required (sight glass level)
pp. 38-52
Maintenance

Maintenance instructions covering magnetic coupling care, inspection/maintenance checklist intervals, operating fluid change and aging determination, gas ballast valve removal/cleaning, silencer nozzle cleaning and vacuum safety valve diaphragm replacement.

  • Dedicated maintenance instructions for the magnetic coupling (M/MC versions)
  • Checklist for inspection and maintenance intervals provided
  • Operating fluid change procedure including determination of aging degree of P3 operating fluid
  • Oiler oil level check for C version only
  • Rinsing/cleaning of rotary vane pump, gas ballast valve disassembly/cleaning, silencer nozzle cleaning
  • Diaphragm replacement on vacuum safety valve described
pp. 53-58
Decommissioning, Recycling and Malfunctions

Shutdown procedures for longer periods, recommissioning steps, disposal guidance, and a malfunction/troubleshooting chapter with a service solutions section.

  • Shutting down for longer periods and recommissioning procedures given
  • General disposal information and disposal procedure per chapter 9
  • Malfunction troubleshooting table in chapter 10; Pfeiffer service solutions in chapter 11
pp. 59-64
Spare Parts and Accessories

Ordering information for spare part packages with their contents, and accessory ordering information with compatible accessories from the Pfeiffer range.

  • Spare part packages with defined contents (chapter 12)
  • Accessory information and ordering data (chapter 13)
pp. 65-72
Technical Data and Dimensions

General technical data, substances in contact with media, dimension drawings for all six pump versions (36/36MC/36M and 70/70MC/70M) and EU/UK declarations of conformity.

  • Dimension drawings for DuoVane 36, 36MC, 36M, 70, 70MC, 70M
  • Substances in contact with media table provided
  • EU and UK Declarations of Conformity included as chapters 15/16

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
DuoVane 36 pumping speed is 32 m³/h at 50 Hz and 36 m³/h at 60 Hz; DuoVane 70 is 62 m³/h (50 Hz) / 70 m³/h (60 Hz) p.15 ↗ Size the pump for the actual mains frequency; 60 Hz operation gives ~10-13% higher throughput whole series
Constant intake pressure max. 50 hPa absolute; exhaust pressure ≤ 1500 hPa absolute and ≥ atmospheric; max. intake medium temperature +40 °C p.9 ↗ Applications requiring continuous operation below 50 hPa or throttled exhaust above 1500 hPa abs are outside the allowed envelope whole series
Ambient temperature range +12 °C to +40 °C, relative humidity max. 85%, permissible inclination ±1° longitudinal / ±2° transverse p.9 ↗ Installation site must be climate-controlled, weatherproof and level within these tilt limits to safeguard operating fluid supply whole series
Protection class IP40 with single-phase motor and IP43 with three-phase motor; housing Type 1 (UL 50E); overvoltage category II, pollution degree 2 p.9 ↗ Pump is not suited for dusty or wet environments without additional enclosure; verify electrical installation category accordingly whole series
M and MC versions have leakage rate ≤ 1×10⁻⁷ Pa m³/s; C and MC use operating fluid F5 with changed vane material p.5 ↗ Choose M/MC for tight applications (e.g. helium leak-test background) and C/MC where corrosive media demand special fluid/vanes DuoVane 36/70 M, C, MC versions
For media with oxygen concentration ≥ 21%, only perfluorinated synthetic oils (F4, F5, A113) may be used; mineral oil is forbidden at > 21% O₂ p.10 ↗ Prevents oil oxidation/ignition risk; specify F-series oil at ordering for oxygen service whole series
Pump has no built-in mains switch; a mains disconnection device with MCB (interruption rating ≥ 10 kA) and RCCB must be installed p.22 ↗ Panel design must include labelled disconnecting means within reach of the pump whole series
Three-phase motors must always be started direct on-line; star-delta start-up is prohibited and causes engine damage p.24 ↗ Do not fit star-delta starters in the supply concept; use DOL contactors three-phase motor versions
With IE2 motors a soft-start relay or frequency converter is recommended; with IE3 motors it is mandatory due to magnetic coupling demagnetization risk p.23 ↗ For M/MC (magnetic coupling) versions with high-efficiency motors, budget a soft-start relay or VFD in the drive spec M and MC versions (magnetic coupling), esp. IE3 motors
Recommended mains fuses are type 'K' circuit breakers with slow tripping characteristics p.23 ↗ Avoid fast-curve breakers which nuisance-trip on pump start current whole series
Rotation direction wiring: 6-pin board U1–L2, V1–L1, W1–L3; 9-pin board T1–L2, T2–L1, T3–L3 give clockwise shaft rotation viewed at motor fan p.24 ↗ Use these assignments to get correct rotation at commissioning before checking direction of rotation three-phase motor versions
The motor restarts automatically after power failure or thermal standstill p.23 ↗ Implement lock-out/tag-out and secure against restart before any work near the vacuum flange whole series
Interchangeable flange screws are tightened to 5 Nm using WAF 5 hex key and a calibrated torque wrench (tightening factor ≤ 2.5) p.19 ↗ Enables safe repositioning of vacuum/exhaust flanges between vertical and horizontal positions without seal damage whole series
Vacuum and exhaust line cross sections must be ≥ nominal flange diameter; piping must be supported so no forces act on the pump; exhaust routed downwards with no shut-off units p.20 ↗ Prevents piping stress on the housing and condensate return; negative exhaust pressure is not permissible whole series
Surface temperature can exceed 70 °C; touch protection required for unrestricted access; keep cables away from surfaces > 70 °C p.9 ↗ Plan guarding/clearances and cable routing for burn protection in the layout whole series
The vacuum safety valve separates the pump from the chamber at standstill and vents it so oil does not migrate into the chamber; valve opens with delay after switch-on p.14 ↗ No external anti-suck-back valve is required for basic isolation, but account for the opening delay in process sequencing whole series
Operating fluid must be changed after storage periods longer than 2 years; pump is stored filled to upper edge of sight glass with gas ballast valve closed p.17 ↗ Include oil-change and level checks in storage/recommissioning SOPs whole series
Magnetic coupling does not provide motor overload protection; motor protection switch setting procedure is required p.25 ↗ Motor protection must be set per nameplate current even for M/MC versions whole series, esp. M/MC versions