HiLobe 1002 — instruction manual hilobe 1002 1302
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HILOBE 1002 / 1302 Roots pumps, in vertical (HiLobe 1002, 1302) and horizontal flow (HiLobe 1002 H, 1302 H) mounting orientations, operated with the original electronic drive unit (RC 5500 shown on rating plate; RC 7500/11000/15000 mentioned for cable sizing). English translation of the original operating instructions, 70 pages.
Section-by-Section Technical Breakdown
Explains the two-lobe, non-contacting roots piston principle with separate gear/bearing chamber lubrication, cantilever coupling-free drive with frequency converter, and lists variants, features and scope of delivery.
- Nominal pumping speeds: HiLobe 1002/1002 H: 260–1050 m3/h; HiLobe 1302/1302 H: 260–1300 m3/h
- Mounting orientation (vertical standard, horizontal option) is factory-set and must not be changed by user
- Scope of delivery includes pump with switch box and FC, reinforcing flange with screws, mating mains plug, 2 temperature sensors, 2 m cable set, lubricant D2
- Sealing gas connections on gearbox and motor side (2× each)
Covers setup (flat surface, 4 × M8 fastening), filling lubricant, connecting vacuum and fore-vacuum sides (DN 100 ISO-F or PN16), switch box, temperature sensors, electrical safety measures and mains connection.
- Lubricant options: D2, P3, H1; D2 may replace D1; fill motor side ~400 ml, opposite side ~250 ml; fill level limiters with riser tubes
- Use start-up strainer in intake flange during commissioning; remove once particle ingress risk excluded
- Pipes > 5 m length need larger nominal diameter than the pump flange
- Prevent gas backflow at fore-vacuum side (shut-off valve or backing pump with vacuum safety valve); install condensate separator at exhaust line low point
- Temperature sensors: M 6 thread in both oil chambers, tightening torque 4 Nm
- Mains cable cross-section: RC 5500 ≥ 2.5 mm², RC 7500/11000 ≥ 6.0 mm², RC 15000 ≥ 10.0 mm²; ≥ 600 V dielectric strength, flame-retardant
- Mains connection: L1/L2/L3 + PE; supply terminal short-circuit capacity Ssc ≥ 351; not for installation in living areas (IEC 61000-3-12)
15-pin D-Sub 'remote' interface for remote operation of the electronic drive unit with voltage output, inputs/outputs and RS-485. Describes the Pfeiffer Vacuum RS-485 protocol with telegram frame and examples.
- Disconnect voltage supply before removing bus plugs; wait for residual load dissipation
- Protocol section covers telegram frame, telegram descriptions, data types
Lists control commands, status requests, reference value inputs and additional control unit parameters, e.g. [P:019], [P:024] for connection configuration and [P:060]/[P:061].
- Parameters printed as [P:xxx]; tables 8–12 define control commands, status requests, reference values
Commissioning, switching on, sealing gas adjustment, operating modes (normal, stand-by, rotation speed setting), operation monitoring via LED and temperature, and switching off/venting.
- LED indicators (green/yellow/red) display operating mode; LEDs meaning in Tbl. 15
- Temperature monitoring via two sensors connected to switch box; lubricant level checked via sight glasses
Maintenance information with interval checklist, cleaning of the fan air filter mat, and lubricant draining/refilling procedures for both oil chambers.
- Maintenance intervals in Tbl. 16; filter mat of fan replaceable (Fig. 17)
- Wear protective equipment when draining hot lubricant
Shutting down for longer periods and recommissioning; general disposal rules and HiLobe-specific disposal.
Troubleshooting table, error codes, and warning/malfunction messages of the electronic drive unit when operating with control units.
- Tbl. 17 troubleshooting, Tbl. 18 error messages, Tbl. 19 warning messages of the electronic drive unit
Pfeiffer Vacuum service solutions, HiLobe spare parts packages (Tbl. 21), accessories and consumables ordering information.
Pressure/gas throughput unit conversion tables, materials in contact with process media, technical data tables for vertical and horizontal flow variants, and dimension drawings incl. RC 5500 drive unit.
- Tbl. 27 technical data vertical flow; Tbl. 28 horizontal flow; dimension drawings DN 100 for both variants
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Nominal pumping speed: HiLobe 1002/1002 H = 260–1050 m³/h; HiLobe 1302/1302 H = 260–1300 m³/h (air/N2) p.21 ↗ | Size backing pump and booster selection by variant; 1302 variants give ~24% higher max speed | all variants |
| Max. pump rotation speed 7500 rpm (rating plate example); max. speed in circulation mode limited to 4200 rpm p.9 ↗ | Frequency converter speed setpoints must respect the circulation-mode limit to avoid overpressure differential | whole series |
| Permissible ambient conditions: +5 °C to +40 °C, max. 85 % relative humidity, max. installation altitude 2000 m, inclination ± 3°, pollution degree 2, protection class I, overvoltage category II, IP54/Type 12 (drive unit) p.16 ↗ | Installation site must be weatherproof indoor; above 1000 m at 40 °C ambient, motor rated power drops ~10 % | whole series |
| Max. pressure differential in circulation mode 80 hPa; permanent intake pressure in circulation mode < 1100 hPa (abs.); permissible Δp decreases with pump speed per Fig. 4 p.16 ↗ | Pressure differential vs. speed curve must be checked when selecting operating point; exceeding Δp risks overloading the pump | whole series |
| Max. gas temperature on pressure side 250 °C p.16 ↗ | Hot process gas must be cooled or dilution applied before entering the pump | whole series |
| Lubricant fill quantities: motor side approx. 400 ml, opposite side approx. 250 ml; oil chambers have fill-level limiters with riser tubes p.25 ↗ | Total oil capacity ~0.65 l (rating plate); overfilling is self-limiting via limiter/drain hole, but correct quantities must be used per mounting orientation | whole series |
| Approved lubricants: D2, P3, H1; D2 is a permitted replacement for D1; mineral lubricant P3 forbidden with O2 concentration > 21 % p.17 ↗ | Only the lubricant used at initial installation may be used thereafter; oxygen applications require non-mineral lubricant | whole series |
| Connection flanges are DN 100 (ISO-F wrench WAF 13 / PN16 wrench WAF 24); pipes > 5 m require a larger nominal diameter than the pump flange p.26 ↗ | Use all prescribed flange bolts and PN16 pressure stage; support piping so no forces act on the pump flanges | whole series |
| Electronic drive unit mains input: 3~ 380–480 V ±10 %, 50/60 Hz, 17 A (RC 5500); output 3~ 400 V, 12.0 A, 0–400 Hz p.9 ↗ | Supply and motor protection switch must match this rating; pump operates only with the original electronic drive unit | RC 5500 drive unit |
| Required mains cable cross-section: RC 5500 ≥ 2.5 mm², RC 7500/11000 ≥ 6.0 mm², RC 15000 ≥ 10.0 mm²; ≥ 600 V dielectric strength, flame-retardant p.31 ↗ | Self-assembled power cables via original plug must meet these minimums | drive-unit specific |
| Connected supply terminal must have short-circuit capacity Ssc ≥ 351 (IEC 61000-3-12); drive unit provides no radio-reception protection, so do not install in living areas p.31 ↗ | Verify network short-circuit capacity with the distribution network operator before installation | whole series |
| Temperature sensors screw into M 6 threads in both oil chambers, tightening torque 4 Nm; extension cables included in scope p.29 ↗ | Motor/oil temperature monitoring wiring must be connected to the switch box before commissioning | whole series |
| Pump and drive unit have no built-in mains disconnection device; a motor protection switch must be installed within reach and labeled as disconnect device p.13 ↗ | Electrical installation must include external motor protection sized per motor rating plate | whole series |
| After switching off, wait at least 5 minutes for capacitor discharge before separating cable connections; never unplug the motor connector with power connected or during run-down p.14 ↗ | Lockout procedure must include this 5-minute delay to prevent electric shock and electronics damage | whole series |
| Mounting orientation (vertical standard / horizontal H option) is factory-defined and cannot be changed in the field — oil supply differs per version and wrong orientation causes bearing lubrication failure p.21 ↗ | Order the correct flow-direction variant; never reinstall a vertical pump horizontally | whole series |
| Surface temperature of the pump can exceed 70 °C during operation p.14 ↗ | Provide touch protection if untrained persons have access; allow cooling before any work | whole series |
| Gas backflow on the fore-vacuum side can irreversibly damage electronics via regenerative energy from piston rotation; a shut-off facility or backing pump with integrated vacuum safety valve is required p.27 ↗ | Fore-vacuum line design must include block-off immediately after switch-off; condensate separator recommended at exhaust low point | whole series |
| Mass ~105 kg (HiLobe 1302 rating plate), drive unit 24 kg; transport via 2 ex-factory eye bolts lifted vertically; never stack, never lift by pipes p.9 ↗ | Lifting gear and floor loading must be sized accordingly; eye bolts removed after transport and kept for reuse | whole series |
| Use a start-up strainer in the intake flange during commissioning; remove only when particle ingress can be excluded (note pumping-speed decrease) p.27 ↗ | Protects suction chamber from weld scale/particles during first operation of new piping | whole series |
| Sealing gas connections (2× gearbox side, 2× motor side) must be used when pumping high-boiling, corrosive or particle-laden media p.19 ↗ | Plan sealing gas supply to protect lubricant and bearings in solvent-contaminated processes | whole series |
| Change lubricant after storage periods exceeding 2 years; suction chamber has no corrosion protection and should be evacuated and backfilled with nitrogen for storage p.23 ↗ | Long-term storage planning must include nitrogen sealing and post-storage oil change | whole series |