HiLobe 11003 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiLobe 8103, 11003 and 14003 vacuum boosters (three-speed variants of the same frame). Data sheet dated 01.07.2025 covering technical specifications, options, accessories and spare parts for all three models.
Section-by-Section Technical Breakdown
The HiLobe series is marketed on reliability, performance and efficiency. Key design features include intelligent condition monitoring via integrated sensors, hermetically sealed IE4 synchronous canned-motor design without shaft seals, variable speed drive, optimized rotor geometries and extended maintenance intervals.
- High up-time due to intelligent condition monitoring via integrated sensors
- High pumping speed and best performance-to-size ratio
- Hermetically sealed synchronous motor (IE4) in canned-motor design, no shaft seals
- Variable speed drive and optimized rotor geometries
- Extended maintenance intervals
A range of factory options and accessories is available for the HiLobe boosters, covering communication, monitoring, cooling, drive electronics and installation variants.
- Profinet converter
- Barrier gas kit (plastic or stainless steel)
- Gear chamber evacuation
- Flushing device (spray lance)
- Temperature and pressure monitoring (inlet and exhaust side)
- Extension cable package
- OmniControl
- Horizontal version
- Operating fluids
- Electronic drive options: box version, mounting plate for switch cabinet integration, without drive electronics
- Cooling options: convection cooling, active-air cooling, water cooling
Performance and specification table for HiLobe 8103, 11003 and 14003: pumping speeds from 2700 up to 13540 m³/h, rotational speeds 1500-7500 rpm, differential pressure limits dependent on speed, common flange size DN 250, 380-480 V AC supply and RC 15000 electronic drive unit. Physical data (dimensions, weight, cooling water, leak rate, operating fluid) is identical across all three models.
- Nominal pumping speed: 2700-8120 m³/h (8103), 2700-10830 m³/h (11003), 2700-13540 m³/h (14003)
- Rotational speed: 1500-4500 rpm (8103), 1500-6000 rpm (11003), 1500-7500 rpm (14003)
- Max. differential pressure at max. speed: 25 hPa (8103), 20 hPa (11003), 10 hPa (14003); 30 hPa at min. speed for all
- Main and secondary flanges: DN 250 ISO-F | DN 250 PN 16 for all models
- Input voltage: 380-480 V AC (±10%), 50/60 Hz; three-phase motor with PTC protection
- Rated power at full speed: 9 kW (8103), 12 kW (11003), 15 kW (14003); recommended mains fuse 50 A
- Electronic drive unit: RC 15000; I/O interfaces PV.can and RS485
- Cooling: water cooling; ambient temperature 5-40 °C; shipping temperature -10-40 °C
- Sound pressure level (EN ISO 2151) at 1 hPa inlet pressure: 70 dB(A)
- Operating fluid: D2, filling 3 l
- Protection degree IP54 / type 12; integral leak rate 1E-06 Pa m³/s
- Dimensions 1115 x 583 x 468 mm; weight approx. 620 kg (all models)
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Max. differential pressure at max. rotational speed is 25 hPa (HiLobe 8103), 20 hPa (11003) and 10 hPa (14003) p.2 ↗ | Higher-speed models tolerate less pressure differential; for applications needing larger ΔP at high throughput, the 8103 at reduced speed (up to 30 hPa) may be required or a backing pump must handle the compression | whole series (model-specific values) |
| All models allow up to 30 hPa differential pressure when operated at minimum rotational speed (1500 rpm) p.2 ↗ | Run at reduced speed during crossover/startup phases where fore-vacuum pressure is high, to stay within the ΔP limit | whole series |
| Rotational speed range: 1500-4500 rpm (8103), 1500-6000 rpm (11003), 1500-7500 rpm (14003) p.2 ↗ | Matching model to required pumping speed (2700-13540 m³/h) via the variable speed drive rather than oversizing the pump | whole series (model-specific values) |
| Rated power at full rotational speed: 9 kW, 12 kW and 15 kW for 8103, 11003, 14003 respectively; recommended mains fuse capacity 50 A p.2 ↗ | Electrical supply and switchgear must be dimensioned for 15 kW peak with 50 A fusing even for the smaller models if using the shared RC 15000 drive | whole series |
| Input voltage 380-480 V AC ±10%, 50/60 Hz, three-phase motor with PTC protection p.2 ↗ | PTC sensor must be wired into the motor protection circuit; supply tolerance must be verified at site before installation | whole series |
| Electronic drive unit is the RC 15000 with PV.can and RS485 I/O interfaces p.2 ↗ | Control integration must use PV.can or RS485; a Profinet converter accessory is required for Profinet networks | whole series |
| Water cooling parameters: pressure 2000-6000 hPa, flow 120-360 l/h, water temperature 5-35 °C p.3 ↗ | Cooling water circuit (pressure, flow rate and temperature) must be within these limits; cooling option alternatives (convection, active-air) exist for sites without water | whole series (water-cooled standard configuration) |
| Ambient temperature 5-40 °C; shipping temperature -10-40 °C p.2 ↗ | Installations below 5 °C or storage below -10 °C are out of spec; protect against freezing and cold-start conditions | whole series |
| Operating fluid is D2 with a filling volume of 3 l p.3 ↗ | Gear oil specification (Pfeiffer D2) and 3 l quantity must be used for initial fill and oil changes; ordering of operating fluid is via accessories | whole series |
| Integral leak rate 1E-06 Pa m³/s p.3 ↗ | Suitable for high-vacuum systems; leak rate should be factored into base-pressure calculations of the pump stack | whole series |
| Protection degree IP54 / type 12 p.3 ↗ | Suitable for indoor industrial environments with dust and dripping water protection; not for wash-down or outdoor use without additional enclosure | whole series |
| All three models share identical dimensions (1115 x 583 x 468 mm) and weight (approx. 620 kg) p.3 ↗ | Identical mounting frames, lifting gear and installation footprint can be used across the range; lifting equipment rated ≥620 kg required | whole series |
| Main and secondary flanges are DN 250 ISO-F or DN 250 PN 16 on all models p.2 ↗ | System piping and adapters must be DN 250 ISO-F (vacuum side) or DN 250 PN 16 (pressure-rated side); identical for inlet and exhaust | whole series |
| Sound pressure level 70 dB(A) (EN ISO 2151) at 1 hPa inlet pressure for all models p.3 ↗ | Noise is uniform across the range and generally does not require dedicated acoustic enclosure at typical industrial exposure limits, but verify against workplace regulations | whole series |
| Canned-motor design with hermetically sealed IE4 synchronous motor, no shaft seals p.1 ↗ | Eliminates shaft-seal leakage as a failure/contamination point and lowers energy consumption; supports hermetic process containment | whole series |
| Optional barrier gas kits are available in plastic or stainless steel versions; gear chamber evacuation and spray-lance flushing devices are offered p.1 ↗ | For particulate-laden or condensable processes, specify barrier gas and flushing options at order time; material choice (plastic vs stainless) depends on process chemistry | whole series (options) |