Induztr
Engineering Digest Document Viewer Related Models

A 1504 XN — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum A 804 XN, A 1504 XN and A 1804 XN multi-stage Roots vacuum pumps (2-page datasheet/brochure, dated 01.07.2025).

Section-by-Section Technical Breakdown

pp. 1
Overview and Key Features

The leaflet introduces the A 804-1804 XN series of multi-stage Roots vacuum pumps, highlighting efficiency, robustness and reliability. Motors are high-efficiency type with limited use of electric heaters for cost-efficient operation. The pumps are suited for harsh semiconductor processes.

  • High-efficiency motors, limited use of electric heaters, cost-efficient
  • Suited for harsh semiconductor processes
  • Nickel coating for increased corrosion resistance
  • Design options available for dealing with by-product generation
  • Extended lifetime / reliable operation
pp. 2
Technical Data, Dimensions and Pumping Speed

A comparison table gives pumping speed, ultimate pressure, power draw, cooling water, noise, weight, dimensions and flange sizes for the three models. Data are specified at 60 Hz operation. All three models share the same ultimate pressure and cooling water requirement.

  • A 804 XN: 600 m³/h nominal pumping speed (60 Hz), DN 100 inlet / DN 40 outlet, 380 kg, 961 x 388 x 776 mm
  • A 1504 XN: 1100 m³/h nominal pumping speed (60 Hz), DN 160 inlet / DN 40 outlet, 540 kg, 961 x 388 x 911 mm
  • A 1804 XN: 1600 m³/h nominal pumping speed (60 Hz), DN 160 inlet / DN 40 outlet, 540 kg, 961 x 388 x 911 mm
  • Ultimate pressure: 1.45 · 10⁻² hPa (mbar) for all models (60 Hz)
  • Power consumption at ultimate pressure: 2.4 / 2.7 / 2.8 kW (60 Hz)
  • Cooling water flow: 2.5 - 5 l/min for all models
  • Sound pressure level: <68 dB(A) (A 804 XN), <69 dB(A) (A 1504 / A 1804 XN)
  • Dimensional drawing and pumping speed curve are shown in this section

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Nominal pumping speeds at 60 Hz: A 804 XN = 600 m³/h, A 1504 XN = 1100 m³/h, A 1804 XN = 1600 m³/h. p.2 ↗ Model selection is driven by required throughput; ~2x and ~2.7x steps between models. A 804 / A 1504 / A 1804 XN
Ultimate pressure is 1.45 · 10⁻² hPa (mbar) at 60 Hz for all three models. p.2 ↗ All models reach the same base pressure; choose model by speed, not by ultimate pressure. whole series
Power consumption at ultimate pressure: 2.4 kW (A 804 XN), 2.7 kW (A 1504 XN), 2.8 kW (A 1804 XN) at 60 Hz. p.2 ↗ Electrical supply sizing: max ~2.8 kW per pump; large speed increase comes with only ~0.4 kW more power than A 804. whole series
Cooling water flow requirement is 2.5 - 5 l/min for all models. p.2 ↗ Water-cooled operation; provide a cooling circuit with adjustable flow in this range for all variants. whole series
Sound pressure level <68 dB(A) for A 804 XN and <69 dB(A) for A 1504/1804 XN. p.2 ↗ Low-noise installation; typically no special acoustic enclosure needed for hearing protection. whole series
Weight: 380 kg (A 804 XN) and 540 kg (A 1504 XN and A 1804 XN). p.2 ↗ Lifting equipment and foundation/rack design must support ≥540 kg for the larger models. A 804 XN vs A 1504/1804 XN
Dimensions: 961 x 388 x 776 mm (A 804 XN) and 961 x 388 x 911 mm (A 1504 XN, A 1804 XN), L x W x H. p.2 ↗ Same footprint (961 x 388 mm) for all models; height differs by 135 mm when planning skid/integration. whole series
Gas inlet/outlet connections: DN 100 / DN 40 for A 804 XN; DN 160 / DN 40 for A 1504 XN and A 1804 XN. p.2 ↗ Piping and flange hardware must match per model; outlet is DN 40 across the series. A 804 XN vs A 1504/1804 XN
Nickel coating is applied for increased corrosion resistance. p.1 ↗ Suitable for corrosive/etch-type process gas environments; still verify chemical compatibility for specific gases. whole series
Design options are available for dealing with by-product generation. p.1 ↗ For condensable by-product-laden semiconductor processes, consult ordering options rather than using the standard configuration. whole series
All stated performance data (speed, ultimate pressure, power) are given at 60 Hz operation. p.2 ↗ Ensure drive supply/frequency converter delivers 60 Hz operation; 50 Hz values are not specified in this document. whole series