Induztr
Engineering Digest Document Viewer Related Models

HiLobe 2703 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum HiLobe vacuum booster series, covering three models: HiLobe 2703, HiLobe 4503 and HiLobe 6203 (nominal pumping speeds 2700/4500/6200 m³/h). Accessories and options include Profinet converter, barrier gas kit (plastic or stainless steel), gear chamber evacuation, spray-lance flushing device, temperature/pressure monitoring, extension cable package, OmniControl, horizontal version, electronic drive variants (box version, switch-cabinet mounting plate, without drive electronics) and cooling options (convection, active-air, water).

Section-by-Section Technical Breakdown

pp. 1
Features, Accessories and Options

The leaflet highlights reliability via integrated-sensor condition monitoring, high pumping speed with best performance-to-size ratio, and efficiency via hermetically sealed IE5 canned-motor design without shaft seals, variable speed drive and extended maintenance intervals. It lists available accessories, drive and cooling options.

  • Intelligent condition monitoring via integrated sensors for high up-time
  • Hermetically sealed synchronous motor (IE5), canned motor design, no shaft seals
  • Variable speed drive and optimized rotor geometries
  • Options: Profinet converter, barrier gas kit (plastic or stainless steel), gear chamber evacuation, spray-lance flushing device
  • Options: temperature and pressure monitoring (inlet and exhaust side), extension cable package, OmniControl, horizontal version, operating fluids
  • Electronic drive options: box version, mounting plate for switch cabinet integration, without drive electronics
  • Cooling options: convection, active-air, water cooling
pp. 2
Performance, Flange and Electrical Data

Pumping speed, rotational speed, differential pressure limits, flange connections and motor/drive electrical data for all three models. All share DN 160 ISO-F / DN 150 PN 16 main and secondary flanges, 380-480 VAC supply and RC 7500 electronic drive unit.

  • Nominal pumping speed: 2703: 890-2700 m³/h; 4503: 890-4500 m³/h; 6203: 890-6200 m³/h
  • Rotational speed: 2703: 1500-4500 rpm; 4503: 1500-7500 rpm; 6203: 1500-10500 rpm
  • Max. differential pressure at max. rotational speed: 2703: 54 hPa; 4503: 36 hPa; 6203: 21 hPa; at min. rotational speed: 65 hPa (all models)
  • Main and secondary flanges: DN 160 ISO-F | DN 150 PN 16 (all models)
  • Input voltage: 380-480 VAC (±10%), 50/60 Hz; three-phase motor with PTC protection
  • Rated power at full rotational speed: 3.5 kW (2703), 5.5 kW (4503), 7.5 kW (6203)
  • Electronic drive unit RC 7500; recommended mains fuse 25 A; I/O interfaces PV.can and RS485
pp. 3
Operating Conditions and Technical Specifications

Installation and operating limits common to all three models: ambient/shipping temperatures, noise level, operating fluid, protection rating, cooling water requirements, leak rate, dimensions and weight.

  • Ambient temperature 5-40 °C; shipping temperature -10-40 °C
  • Sound pressure level (EN ISO 2151) at 1 hPa inlet pressure: 60 dB(A) (all models)
  • Operating fluid D2, filling volume 1 l
  • Protection degree IP54; type 12
  • Cooling water: pressure 2000-6000 hPa, flow 120-360 l/h, temperature 5-35 °C
  • Integral leak rate 1E-06 Pa m³/s
  • Dimensions (L x W x H) 860 x 428 x 354 mm; weight approx. 258 kg (all models)

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Maximum allowable differential pressure falls with speed: 54 hPa (2703), 36 hPa (4503), 21 hPa (6203) at maximum rotational speed, versus 65 hPa for all models at minimum speed (1500 rpm). p.2 ↗ For high-pressure-difference pumping, run the booster at reduced speed; at full speed the 6203 tolerates only 21 hPa across it, so the backing pump must hold the exhaust pressure close to inlet pressure. All models, differential pressure limits model-specific
Rotational speed ranges: 1500-4500 rpm (2703), 1500-7500 rpm (4503), 1500-10500 rpm (6203). p.2 ↗ Speed selection via the variable-speed drive directly scales pumping speed; the 6203 reaches its 6200 m³/h only near 10500 rpm. Model-specific
Both main and secondary flanges are DN 160 ISO-F | DN 150 PN 16 on all models. p.2 ↗ Inlet and outlet connections are identical, simplifying piping and allowing series stacking with backing pumps. Whole series
Supply voltage 380-480 VAC ±10%, 50/60 Hz; recommended mains fuse 25 A; electronic drive unit RC 7500. p.2 ↗ Site wiring and breaker sizing can be standardized across all three models; drive electronics must be RC 7500 or ordered without drive for external integration. Whole series
Rated motor power: 3.5 kW (2703), 5.5 kW (4503), 7.5 kW (6203) at full rotational speed. p.2 ↗ Electrical supply sizing differs per model despite identical fuse recommendation; check motor power when pairing with drive electronics. Model-specific
Motor is a hermetically sealed IE5 synchronous canned motor with no shaft seals. p.1 ↗ No shaft-seal leaks into the process and reduced maintenance; integral leak rate is 1E-06 Pa m³/s. Whole series
Motor protection via PTC sensors; I/O interfaces PV.can and RS485. p.2 ↗ PTC must be wired into the drive/control for thermal protection; PV.can/RS485 used for condition monitoring and control integration (Profinet via optional converter). Whole series
Cooling water requirements: pressure 2000-6000 hPa (0.2-0.6 bar relative range), flow 120-360 l/h, temperature 5-35 °C; standard cooling method water cooling. p.2 ↗ A qualified cooling water loop must be provided; convection and active-air cooling variants are available as options if water is impractical. Whole series
Ambient temperature 5-40 °C, shipping/storage temperature -10-40 °C. p.2 ↗ Installation spaces below 5 °C require heating; units must not be stored below -10 °C. Whole series
Sound pressure level 60 dB(A) per EN ISO 2151 at 1 hPa inlet pressure for all models. p.3 ↗ Noise is typically not a limiting factor even for the largest 6203 at high speed; no special acoustic enclosure needed for most installations. Whole series
Operating fluid D2 with 1 l filling volume on all models. p.3 ↗ Gear/oil chamber service uses Pfeiffer D2 fluid; keep 1 l stock per unit for oil changes; extended maintenance intervals claimed. Whole series
Protection degree IP54, type 12; all three models share identical dimensions 860 x 428 x 354 mm and weight approx. 258 kg. p.3 ↗ Identical footprint allows model swaps without foundation or enclosure changes; lifting gear for ≥258 kg required; IP54 enclosure suits dusty industrial environments. Whole series
Options include barrier gas kit (plastic or stainless steel), gear chamber evacuation, spray-lance flushing device, and inlet/exhaust temperature and pressure monitoring. p.1 ↗ For dusty or condensable processes, specify barrier gas and flushing options at ordering time; monitoring sensors enable the integrated condition monitoring strategy. Whole series (options)
Drive electronics can be ordered as box version, as mounting plate for switch cabinet integration, or without drive electronics. p.1 ↗ Control-cabinet design determines which drive variant to order; cabinet-integrated versions save floor space but require thermal planning. Whole series (ordering options)