Technical Reference Summary

Covered Models & Document Scope

Busch COBRA DS dry screw vacuum pumps, two variants: COBRA DS 0080 G and COBRA DS 0160 G. Data given for 50 Hz and 60 Hz operation; applications cited: CVD, RTP, ALD.

Section-by-Section Technical Breakdown

pp. 1
Product Overview

Brochure page introducing the COBRA DS 0080/0160 G dry screw vacuum pumps, highlighting performance, efficiency and compactness. Suited to semiconductor processes (CVD, rapid thermal processing, ALD). Features indirect water cooling and a directly mounted canned motor.

  • Advanced screw design, suited to CVD, RTP and ALD applications
  • Low cost of ownership, minimal maintenance, long service intervals, high uptime
  • Efficient indirect water cooling, high hydrogen throughput
  • Fit-in-place compact design with directly mounted canned motor
pp. 2
Technical Data, Pumping Speed Curves and Dimensional Drawing

Page 2 provides a dimensional drawing and pumping speed curves (air at 20 °C, tolerance ±10%) for both variants plus tabulated technical data at 50/60 Hz.

  • Nominal pumping speed: 70/85 m³/h (DS 0080 G), 140/160 m³/h (DS 0160 G) at 50/60 Hz
  • Ultimate pressure: 0.03 hPa (mbar) for both models
  • Nominal motor rating: 4.0/4.4 kW (0080 G), 5.5/6.6 kW (0160 G)
  • Power consumption at ultimate pressure: 2.6/3.2 kW (0080 G), 4.3/5.2 kW (0160 G)
  • Nominal motor speed: 3000/3600 min⁻¹ (both models)
  • Sound pressure level (ISO 2151, KpA=3 dB): <62 dB(A) (0080 G), <68 dB(A) (0160 G)
  • Cooling water consumption: 4.0 l/min (both models, 50/60 Hz)
  • Nitrogen consumption: 0–75 l/min (both models)
  • Weight: 276 kg (0080 G), 338 kg (0160 G)
  • Dimensions L×W×H: 865×385×667 mm (0080 G), 975×425×697 mm (0160 G)
  • Gas inlet/outlet: DN 40/DN 40 (0080 G), DN 50/DN 40 (0160 G)

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Pumping speed curves are valid for air at 20 °C with a tolerance of ±10%. p.2 ↗ Size the pump with a 10% margin relative to curve values when matching process gas loads. Both models
Ultimate pressure is 0.03 hPa for both models at 50 and 60 Hz. p.2 ↗ Both variants reach identical base vacuum; model choice is driven by required pumping speed, not ultimate pressure. Both models
Nominal pumping speed: DS 0080 G = 70/85 m³/h, DS 0160 G = 140/160 m³/h at 50/60 Hz. p.2 ↗ 60 Hz operation gives ~20% higher speed; verify required speed at the actual mains frequency. Both models
Nominal motor rating: 4.0/4.4 kW (0080 G) and 5.5/6.6 kW (0160 G) at 50/60 Hz. p.2 ↗ Dimension the electrical supply and protection devices for the 60 Hz rating if frequency-flexible operation is planned. Both models
Power consumption at ultimate pressure: 2.6/3.2 kW (0080 G) and 4.3/5.2 kW (0160 G). p.2 ↗ Expected steady-state power draw is well below nominal motor rating; useful for energy cost estimates. Both models
Cooling water consumption is 4.0 l/min for both models at 50 and 60 Hz (indirect water cooling). p.2 ↗ A single cooling-water supply specification covers both pump sizes; size the chiller/loop accordingly. Both models
Nitrogen consumption ranges from 0 to 75 l/min. p.2 ↗ Provide nitrogen purge supply up to 75 l/min if purge (e.g. dilution of condensables/process gases) is required. Both models
Sound pressure level: <62 dB(A) (0080 G) and <68 dB(A) (0160 G), measured per ISO 2151, KpA = 3 dB. p.2 ↗ Both pumps can typically be installed without dedicated acoustic enclosures for many workplace noise limits. Both models (per-variant values)
Weights: 276 kg (0080 G) and 338 kg (0160 G). p.2 ↗ Lifting equipment and mounting foundations must be rated for ~340 kg worst case. Both models
Dimensions: 865×385×667 mm (0080 G) and 975×425×697 mm (0160 G), L×W×H. p.2 ↗ Compact footprint allows fit-in-place installation; verify clearance for the dimensional drawing on p.2. Both models
Gas connections: DN 40 inlet / DN 40 outlet (0080 G); DN 50 inlet / DN 40 outlet (0160 G). p.2 ↗ The 0160 G requires a larger DN 50 inlet line to realize its higher pumping speed; keep inlet tubing adequately sized. Model-specific
Nominal motor speed is 3000/3600 min⁻¹ at 50/60 Hz; motor is a directly mounted canned motor. p.1 ↗ Two-pole direct-drive design (no gearbox); pump speed scales directly with mains frequency. Both models
Design targets CVD, rapid thermal processing and atomic layer deposition with high hydrogen throughput. p.1 ↗ Suitable for semiconductor process exhaust with hydrogen-rich gas streams; dry screw design needs no pump lubricant in the gas path. Both models