ACP 15 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum ACP series multi-stage dry Roots vacuum pumps: ACP 15, ACP 28 and ACP 40. Brochure covers key data, dimensional drawing, pumping speed curves, accessories and options (dust filter, external silencer, isolation valve, maintenance packages, corrosive-gas/vapor/gas-recirculation/fluorine-free versions, remote electronics for radiative environments). Dated 01.07.2025.
Section-by-Section Technical Breakdown
The ACP 15-40 series is a dry, oil- and contact-free multi-stage Roots pump line offering constant pumping speed and low ultimate pressure with no wearing parts in the compression chamber. Various accessories and special versions are available, including corrosive-gas, condensable-vapor, gas-recirculation and fluorine-free variants.
- Hydrocarbon-free, oil- and contact-free operation (dry pumping)
- No wearing parts inside the compression chamber, long life cycle
- Accessories: dust filter, external silencer, isolation valve, preventive maintenance packages
- Special versions: corrosive gases, condensable vapor pumping, gas recirculation, fluorine-free pumping
- Remote electronics available for radiative environments
Tabulated performance data for ACP 15, ACP 28 and ACP 40, covering pumping speed, ultimate pressure, power consumption, supply voltages, noise, cooling, leak rate and flange connections. Applies to 50/60 Hz operation; water pumping capacity of ACP 28/40 depends on configuration.
- Max. pumping speed: 14 m³/h (ACP 15), 27 m³/h (ACP 28), 37 m³/h (ACP 40)
- Ultimate pressure without dilution: 5·10⁻² mbar (ACP 15), 4·10⁻² mbar (ACP 28/40); with gas-ballast valve: 3·10⁻¹ and 2·10⁻¹ mbar
- Max. continuous inlet pressure: 1013 mbar for all models
- Max. water pumping capacity: 80 g/h (ACP 15), 120-700 g/h (ACP 28/40, depending on configuration)
- Power consumption: 0.45/0.7 kW at ultimate pressure, max 0.55/1.05 kW
- Supply voltage 1-phase: 100-230 VAC; 2-phase: 200-440 VAC
- Sound pressure level at ultimate pressure: <65 dB(A); air cooled
- Max. leak rate: 5·10⁻⁷ hPa·l/s
- Flanges: ACP 15 in DN 25 ISO-KF / out DN 16 ISO-KF; ACP 28 in DN 25 / out DN 25; ACP 40 in DN 40 / out DN 25 ISO-KF
Footprint and mass data for installation planning. Dimensional drawing and pumping speed curves (50/60 Hz) are provided on page 2.
- ACP 15: 514 x 190 x 270 mm (L x W x H), 23 kg
- ACP 28: 647 x 193 x 322 mm, 30 kg
- ACP 40: 647 x 193 x 322 mm, 32 kg
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Max. pumping speed: 14 m³/h (ACP 15), 27 m³/h (ACP 28), 37 m³/h (ACP 40) p.15 ↗ | Select model by required throughput; ACP 40 offers ~2.6x the speed of ACP 15 | ACP 15/28/40 |
| Ultimate pressure without dilution: 5·10⁻² mbar (ACP 15), 4·10⁻² mbar (ACP 28/40); with gas-ballast valve 3·10⁻¹ and 2·10⁻¹ mbar p.15 ↗ | Opening the gas-ballast valve degrades ultimate pressure by roughly one order of magnitude; account for this when pumping condensates | ACP 15/28/40 |
| Max. continuous inlet pressure is 1013 mbar for all three models p.15 ↗ | Pumps can start/start at atmospheric pressure without a backing pump | whole series |
| Max. water pumping capacity: 80 g/h (ACP 15), 120-700 g/h (ACP 28/40, depending on configuration) p.15 ↗ | For high water vapor loads choose ACP 28/40 with appropriate configuration | whole series; ACP 28/40 configuration-dependent |
| Power consumption at ultimate pressure 0.45 kW (ACP 15) / 0.7 kW (ACP 28/40); max 0.55 kW / 1.05 kW p.15 ↗ | Size electrical supply/fusing for max power consumption, not ultimate-pressure value | whole series |
| Supply voltage 1-phase 100-230 VAC; 2-phase 200-440 VAC p.15 ↗ | Wide voltage range simplifies integration into different mains supplies | whole series |
| Sound pressure level at ultimate pressure <65 dB(A) for all models p.15 ↗ | Suitable for laboratory/quiet environments; external silencer available if further reduction needed | whole series |
| Cooling method: air cooling only (no water cooling) p.15 ↗ | Ensure adequate ambient airflow around the unit; no cooling-water plumbing required | whole series |
| Max. leak rate 5·10⁻⁷ hPa·l/s p.15 ↗ | Tightness requirement for system leak-check acceptance criteria | whole series |
| Inlet/outlet flanges: ACP 15 DN 25/DN 16 ISO-KF; ACP 28 DN 25/DN 25 ISO-KF; ACP 40 DN 40/DN 25 ISO-KF p.15 ↗ | ACP 40 requires a larger DN 40 inlet line to realize its 37 m³/h speed; use correct KF clamps and centering rings | specific per model |
| Dimensions/weight: ACP 15 514x190x270 mm, 23 kg; ACP 28 647x193x322 mm, 30 kg; ACP 40 647x193x322 mm, 32 kg p.15 ↗ | Compact bench-mountable units; identical envelope for ACP 28/40 allows interchange | whole series |
| Dry compression chamber contains no wearing parts and operates oil- and contact-free p.15 ↗ | No oil management or contamination risk in pumped gas; low maintenance with preventive maintenance packages recommended | whole series |
| Versions available for corrosive gases, condensable vapor pumping, gas recirculation, and fluorine-free pumping; remote electronics for radiative environments p.15 ↗ | Specify the correct variant at ordering time based on process gas; standard unit is not necessarily suitable for corrosive service | whole series |
| Accessories: dust filter, external silencer, isolation valve p.15 ↗ | Add dust filter for particulate-laden processes and isolation valve for system isolation; include in ordering | whole series |