A 100 L — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum A 100 L / A 100 L ES / A 200 L multi-stage Roots vacuum pumps. Leaflet (2 pages) covers three variants with key technical data, dimensional drawing and pumping speed curves; the A 100 L ES is a low-ultimate-pressure variant with reduced power consumption.

Section-by-Section Technical Breakdown

pp. 1
Product Highlights

Introductory page positioning the A 100/200 L series as high-performance multi-stage Roots pumps. Key selling points: low ultimate pressure with high throughput, modern communication protocols for process integration, and compact design with adjustable inlet position for tool or sub-floor integration.

  • High performance: low ultimate pressure, high throughput
  • Intelligent: state-of-the-art communication protocols adaptable to process requirements
  • Compact: easy integration on tools or in sub-floor areas thanks to adjustable inlet position
  • Series covers A 100 L and A 200 L multi-stage Roots pumps
pp. 2
Technical Data and Dimensions

Page 2 provides a comparison table of nominal pumping speed, ultimate pressure, power consumption, cooling water flow, noise, weight, dimensions and flange connections for the three variants, plus a dimensional drawing and pumping speed curves.

  • Nominal pumping speed: 100 m³/h (A 100 L and A 100 L ES), 200 m³/h (A 200 L)
  • Ultimate pressure: 0.012 hPa (A 100 L), 0.003 hPa (A 100 L ES), 0.013 hPa (A 200 L)
  • Power consumption at ultimate pressure: 1.6 kW (A 100 L), 0.8 kW (A 100 L ES), 0.7 kW (A 200 L)
  • Cooling water flow: 1.6 l/min for all variants
  • Sound pressure level: 58 dB(A) (A 100 L / A 200 L), 55 dB(A) (A 100 L ES)
  • Weight approx. 100 kg for all variants
  • Dimensions 600 x 280 x 300 mm (L x W x H) for all variants
  • Gas inlet / outlet: DN 50 KF / DN 25 KF for all variants
  • Dimensional drawing and pumping speed curves included

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ultimate pressure is 0.012 hPa for A 100 L, 0.003 hPa for A 100 L ES and 0.013 hPa for A 200 L p.2 ↗ For applications below ~0.01 hPa, select the A 100 L ES variant; A 100 L and A 200 L are essentially equivalent in ultimate pressure all variants individually
Power consumption at ultimate pressure: 1.6 kW (A 100 L), 0.8 kW (A 100 L ES), 0.7 kW (A 200 L) p.2 ↗ The A 100 L ES halves power draw vs. A 100 L despite same pumping speed; the A 200 L offers double the speed at the lowest power — size electrical supply accordingly all variants
Cooling water flow requirement is 1.6 l/min for all three variants p.2 ↗ All variants are water-cooled; provision a chilled water loop of at least 1.6 l/min per pump whole series
Dimensions are identical at 600 x 280 x 300 mm (L x W x H) for all variants and weight approx. 100 kg p.2 ↗ A 100 L and A 200 L are form-factor interchangeable, simplifying footprint planning and mechanical integration in tools or sub-floor installations whole series
Gas inlet is DN 50 KF and outlet DN 25 KF on all variants p.2 ↗ Specify KF 50 upstream and KF 25 downstream hardware; no per-variant connection differences whole series
Sound pressure level is 58 dB(A) for A 100 L and A 200 L, 55 dB(A) for A 100 L ES p.2 ↗ All variants meet typical lab/industrial noise limits without additional acoustic measures all variants
Nominal pumping speed is 100 m³/h for A 100 L / A 100 L ES and 200 m³/h for A 200 L p.2 ↗ Doubling throughput requires the A 200 L without changing the envelope footprint all variants
Inlet position is adjustable p.1 ↗ Pump orientation can be adapted to tool or sub-floor layouts during installation planning whole series
The pumps support state-of-the-art communication protocols adaptable to process requirements p.1 ↗ Plan for digital process-control integration; confirm exact protocol options with Pfeiffer Vacuum since specific interfaces are not listed in this leaflet whole series