HiLobe 11004 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum HiLobe series vacuum boosters, covering three models: HiLobe 8104, HiLobe 11004, and HiLobe 14004. Includes available accessories and options (Profinet converter, barrier gas kit, gear chamber evacuation, flushing device, temperature/pressure monitoring, OmniControl, horizontal version, drive and cooling options).

Section-by-Section Technical Breakdown

pp. 1
Product Highlights

Overview of the HiLobe vacuum booster series emphasizing reliability, performance and efficiency. Key design features include intelligent condition monitoring with integrated sensors, high pumping speed with best performance-to-size ratio, and a hermetically sealed IE4 synchronous canned motor with no shaft seals.

  • High up-time due to intelligent condition monitoring via integrated sensors
  • High pumping speed and best performance-to-size ratio
  • Hermetically sealed synchronous motor (IE4), variable speed drive, optimized rotor geometries
  • Canned motor design — no shaft seals, extended maintenance intervals
pp. 1
Accessories, Spare Parts and Options

Lists optional accessories and configurations for the HiLobe series. Includes communication, monitoring, installation and drive/cooling options.

  • Profinet converter
  • Barrier gas kit (plastic or stainless steel)
  • Gear chamber evacuation
  • Flushing device (spray lance)
  • Temperature and pressure monitoring (inlet and exhaust side)
  • Extension cable package
  • OmniControl
  • Horizontal version
  • Operating fluids
  • Electronic drive options: box version, mounting plate for switch cabinet integration, without drive electronics
  • Cooling options: convection cooling, active-air cooling, water cooling
pp. 2
Technical Data — Performance and Electrical

Performance comparison table for HiLobe 8104, 11004 and 14004, covering pumping speed, rotational speed, differential pressure limits, flanges, power ratings and drive electronics. All models share DN 250 flanges, the RC 15000 electronic drive unit and 380-480 V AC supply.

  • Nominal pumping speed: 8104: 2700-8120 m³/h; 11004: 2700-10830 m³/h; 14004: 2700-13540 m³/h
  • Rotational speed: 8104: 1500-4500 rpm; 11004: 1500-6000 rpm; 14004: 1500-7500 rpm
  • Max. differential pressure at max. rotational speed: 8104: 25 hPa; 11004: 20 hPa; 14004: 10 hPa; at min. speed: 30 hPa for all
  • Main and secondary flanges: DN 250 ISO-F or DN 250 PN 16 (all models)
  • Input voltage: 380-480 V AC (±10%), 50/60 Hz; three-phase motor with PTC protection
  • Rated power at full rotational speed: 9 kW (8104), 12 kW (11004), 15 kW (14004)
  • Electronic drive unit: RC 15000; recommended mains fuse: 50 A
  • I/O interfaces: PV.can, RS485; cooling: active air cooling; ambient temperature 5-40 °C
pp. 3
Technical Data — Physical and Operating

Physical, acoustic and operating data, identical across all three models. Includes sound level, operating fluid, protection degree, leak rate, dimensions and weight.

  • Shipping temperature: -10 to 40 °C
  • Sound pressure level (EN ISO 2151) at inlet pressure 1 hPa: 75 dB(A)
  • Operating fluid: D2, filling quantity 5.2 l
  • Protection degree: IP54; type 12
  • Integral leak rate: 1E-06 Pa m³/s
  • Dimensions (L x W x H): 1433 x 583 x 468 mm; weight approx. 670 kg

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Max. differential pressure at max. rotational speed differs by model: 25 hPa (8104), 20 hPa (11004), 10 hPa (14004); at min. rotational speed all models allow 30 hPa. p.2 ↗ Higher-speed models tolerate less pressure rise at full speed; applications with high differential pressure must operate at reduced rotational speed or select the 8104. HiLobe 8104 / 11004 / 14004
Nominal pumping speed ranges: 8104: 2700-8120 m³/h; 11004: 2700-10830 m³/h; 14004: 2700-13540 m³/h. p.2 ↗ Speed selection must match required pumping speed range; all models share the same DN 250 connection, so throughput scales with rotor speed choice. HiLobe 8104 / 11004 / 14004
Rotational speed ranges: 1500-4500 rpm (8104), 1500-6000 rpm (11004), 1500-7500 rpm (14004). p.2 ↗ Variable speed drive (RC 15000) allows throttling performance between these limits for process matching. HiLobe 8104 / 11004 / 14004
Rated power at full rotational speed: 9 kW (8104), 12 kW (11004), 15 kW (14004). p.2 ↗ Electrical supply and cabling must be sized for up to 15 kW; drive sizing per model differs despite identical mechanical footprint. HiLobe 8104 / 11004 / 14004
Input voltage is 380-480 V AC (±10%), 50/60 Hz, three-phase, with recommended mains fuse capacity of 50 A. p.2 ↗ Installation requires a 50 A fused three-phase supply in the 380-480 V range; verify site voltage tolerance. whole series
Motor is a hermetically sealed IE4 synchronous canned motor without shaft seals, with PTC motor protection. p.1 ↗ No shaft-seal maintenance or leak path at the shaft; PTC sensors must be wired into the monitoring circuit for thermal protection. whole series
Electronic drive unit is RC 15000 for all models; electronic drive options include box version, switch-cabinet mounting plate, or no drive electronics. p.1 ↗ Drive packaging can be selected to fit installation constraints; without-drive option allows use of an existing compatible inverter. whole series
I/O interfaces: PV.can and RS485; optional Profinet converter available. p.2 ↗ Integration into PLC/SCADA requires PV.can or RS485 natively; add Profinet converter for Profinet networks. whole series
Cooling method for the standard configuration is active air cooling; convection and water cooling are available as options. p.2 ↗ Ensure airflow clearance for active-air cooled units; water cooling option suits hot or confined environments. whole series
Ambient temperature range is 5-40 °C; shipping/storage temperature is -10 to 40 °C. p.2 ↗ Installation sites must be kept above 5 °C; transport and storage can tolerate down to -10 °C. whole series
Main and secondary flanges: DN 250 ISO-F or DN 250 PN 16. p.2 ↗ Vacuum (ISO-F) or pressure-rated (PN 16) connections can be chosen; piping must match DN 250 on both inlet and outlet. whole series
Sound pressure level is 75 dB(A) (EN ISO 2151) at inlet pressure 1 hPa for all models. p.3 ↗ Noise emission is uniform across the series; workplace noise planning can use 75 dB(A) as a common figure. whole series
Operating fluid is D2 with a filling quantity of 5.2 l for all models. p.3 ↗ Stock D2 operating fluid in at least 5.2 l quantities per pump for oil changes; gear lubrication is oil-based despite canned motor design. whole series
Integral leak rate is 1E-06 Pa m³/s. p.3 ↗ Suitable for high-vacuum systems; downstream/upstream components must meet comparable tightness to preserve system base pressure. whole series
Protection degree IP54 / type 12; dimensions 1433 x 583 x 468 mm (L x W x H); weight approx. 670 kg. p.3 ↗ Identical footprint for all three models simplifies installation planning; lifting gear rated for ≥670 kg is required for handling. whole series
Options include barrier gas kit (plastic or stainless steel), gear chamber evacuation, spray-lance flushing device, and inlet/exhaust temperature and pressure monitoring. p.1 ↗ For particle-laden or condensable processes, specify the flushing device and barrier gas kit; monitoring options support the advertised condition monitoring. whole series