HiScroll 12 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiScroll 6, HiScroll 12 and HiScroll 18 dry scroll vacuum pumps (2-page product brochure, dated 13.08.2025). Covers standard models plus options/accessories: tip seal and bearing kits, gas-ballast valve kit, bellows/cover/electronics kits, exhaust silencer, inlet filter, automated vacuum safety valve, OmniControl controller, EtherCAT and Profinet converters, single-phase VSD version (with or without integrated pressure gauge), three-phase version for HiScroll 18, and a C-Version for corrosive gas.
Section-by-Section Technical Breakdown
Highlights the pumps' performance against atmosphere with high pumping speeds and short cycle times, plus low noise and vibration suitable for noise-sensitive environments. Claims over 50% lower energy consumption than conventional scroll pumps and fully dry operation without operating fluids.
- High performance when evacuating against atmosphere; constant pumping speeds and short cycle times
- Low noise and vibration levels for noise-sensitive working environments
- More than 50% lower energy consumption compared to conventional scroll vacuum pumps
- No operating fluids (oil-free/dry) operation required
Lists available spare part kits, accessories and configuration options for the HiScroll series, including maintenance kits, connectivity converters and special gas versions.
- Maintenance kits: tip seal replacement kit, tip seal and bearing replacement kit
- Accessories: gas-ballast valve kit, bellows kit, cover kit, electronics kit, exhaust silencer, inlet filter
- Process protection: automated vacuum safety valve
- Control/connectivity: OmniControl control device, EtherCAT converter, Profinet converter
- Electrical variants: single-phase VSD version, single-phase VSD version with integrated pressure gauge, three-phase version for HiScroll 18
- C-Version: corrosive gas version
Performance table for HiScroll 6, 12 and 18 including pumping speed (with boost mode), ultimate pressures at different gas-ballast settings, power consumption, motor speeds, noise level, weight, dimensions and flange connections. Pumping speed data is for air at 20 °C with ±10% tolerance; curves given for 50 Hz and 60 Hz.
- Pumping speed: 6.1 / 12.1 / 18.1 m³/h (HiScroll 6/12/18); boost mode: 7.2 / 14 / 21.5 m³/h
- Ultimate pressure (gas-ballast closed): 0.015 / 0.006 / 0.006 hPa(mbar)
- Ultimate pressure (gas-ballast open stage 1): 0.07 / 0.05 / 0.05 hPa(mbar); stage 2: 0.4 hPa(mbar) all models
- Power consumption at ultimate pressure: 165 / 190 / 235 W; at standby speed: 80 / 100 / 100 W
- Motor speed range: 1000–3000 min⁻¹ (HiScroll 6), 624–1870 min⁻¹ (HiScroll 12/18); nominal 2500 / 1560 / 1560 min⁻¹
- Sound pressure level (ISO 3744, accuracy grade 2): 48 dB(A) (HiScroll 6), 47 dB(A) (HiScroll 12/18)
- Weight: 19 / 24 / 23 kg; Dimensions: 380×220×257 mm (HiScroll 6), 419×265×304 mm (HiScroll 12/18)
- Gas inlet/outlet: DN 25 ISO-KF / DN 25 ISO-KF on all models
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Pumping speed is 6.1 m³/h (HiScroll 6), 12.1 m³/h (HiScroll 12) and 18.1 m³/h, with boost mode speeds of 7.2, 14 and 21.5 m³/h respectively (air at 20 °C, tolerance ±10%). p.2 ↗ | Size the pump with ±10% tolerance on curves; use boost mode when faster evacuation/shorter cycle times are needed at the cost of higher power draw. | HiScroll 6, 12, 18 |
| Ultimate pressure with gas-ballast valve closed: 0.015 hPa (HiScroll 6), 0.006 hPa (HiScroll 12 and 18). p.2 ↗ | For finest vacuum, HiScroll 12/18 reach about 2.5× lower ultimate pressure than HiScroll 6; do not specify HiScroll 6 where <0.01 mbar base pressure is required. | HiScroll 6 vs 12/18 |
| With gas-ballast valve open at stage 1, ultimate pressure degrades to 0.07 / 0.05 / 0.05 hPa; at stage 2 it is 0.4 hPa on all models. p.2 ↗ | Using gas ballast for vapor handling trades base pressure for condensate tolerance — expect ~0.4 mbar floor at full ballast. | All models |
| Power consumption at ultimate pressure is 165 / 190 / 235 W; at standby speed only 80 / 100 / 100 W. p.2 ↗ | Standby speed reduces idle power roughly in half — useful in cyclic processes; enables conservative power supply sizing. | All models |
| Motor speed range is 1000–3000 min⁻¹ (HiScroll 6, nominal 2500 min⁻¹) and 624–1870 min⁻¹ (HiScroll 12/18, nominal 1560 min⁻¹). p.2 ↗ | Speeds are variable (VSD-based); match VFD/converter settings to these ranges when integrating with OmniControl or fieldbus options. | All models |
| Sound pressure level is 48 dB(A) for HiScroll 6 and 47 dB(A) for HiScroll 12/18 (ISO 3744, accuracy grade 2). p.2 ↗ | Suitable for desk-side/laboratory installation without acoustic enclosures. | All models |
| All models use DN 25 ISO-KF for both gas inlet and outlet. p.2 ↗ | Standardize on KF25 hardware (clamps, centering rings, flexible hose/bellows — bellows kit available) for installation. | All models |
| Weights are approx. 19 kg (HiScroll 6), 24 kg (HiScroll 12) and 23 kg (HiScroll 18); footprints are 380×220×257 mm and 419×265×304 mm. p.2 ↗ | Single-person handling is feasible; plan bench/cabinet space per these envelope dimensions including clearance for fittings. | HiScroll 6 (small frame); HiScroll 12/18 (shared frame) |
| Consumable maintenance kits exist for tip seals (tip seal kit; tip seal and bearing kit). p.1 ↗ | Tip seals are the primary wear item — schedule replacement intervals using the tip seal kit; bearing service requires the combined kit. | All models |
| Optional automated vacuum safety valve is available as an accessory. p.1 ↗ | Specify it to protect the pump/system against sudden pressure surges or to isolate the inlet automatically at atmospheric operation. | All models |
| Fieldbus integration via EtherCAT and Profinet converters and the OmniControl control device is offered. p.1 ↗ | For automated/remote operation (speed control, monitoring), select the converter matching the plant bus system or run via OmniControl. | All models |
| Single-phase VSD versions (with or without integrated pressure gauge) are standard options; a three-phase version exists for HiScroll 18. p.1 ↗ | HiScroll 6/12 can run on single-phase supply via VSD; for HiScroll 18 on three-phase supply, order the dedicated three-phase variant. | HiScroll 6/12 (single-phase VSD), HiScroll 18 (three-phase) |
| A C-Version (corrosive gas version) is available in the HiScroll series. p.1 ↗ | For processes with corrosive species, order the C-Version rather than the standard pump to protect internal components. | All models (as option) |
| An inlet filter and exhaust silencer are offered as accessories; gas-ballast valve can be retrofitted via kit. p.1 ↗ | Include the inlet filter for particulate-laden processes and the exhaust silencer to further reduce noise; gas ballast can be added later without pump exchange. | All models |
| The pumps operate without any operating fluids (dry scroll principle) and consume over 50% less energy than conventional scroll pumps per manufacturer claim. p.1 ↗ | No oil management or oil-mist exhaust handling is needed, simplifying installation and eliminating oil contamination risk in the pumped system; energy savings apply to total cost of ownership calculations. | Whole series |