COMBI WS 0245 WV2D — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum COMBI WVD / WS vacuum pump units combining PANDA vacuum boosters (WV 0250 C, WV 0500 C, WV 1200 A, WV 2200 A) with DuoVane rotary vane backing pumps (DuoVane 36/70/135/300). Variants covered: COMBI WVD 0220, 0235, 0245, 0400, 0440, 0470, 0900, 0950, 1800 and twin-backing-pump versions COMBI WS 0245/0440/0900 WV2D. Accessories/options: control unit, oil mist separator, OFC chemical / OFM mechanical oil filters, gas-ballast valve kit, operations monitoring unit, SAS dust separator, KAS condensate separator, various feet (height-adjustable, castor wheels, floor mounting).
Section-by-Section Technical Breakdown
COMBI WVD units combine proven DuoVane rotary vane backing pumps with PANDA vacuum boosters for reliable operation with minimal maintenance. The concept targets high pumping speed at low ultimate pressures and fast pump-down times. Various combinations of backing pumps and boosters are available as design options.
- Robust, proven DuoVane backing pumps enhanced by PANDA vacuum boosters
- High pumping speed at low ultimate pressures and fast pump-down times
- Flexible: different booster/backing-pump combinations possible
A list of available accessories and options for the COMBI WVD series is provided, covering filtration, condensate handling, monitoring, control and mounting hardware.
- Control unit for booster and backing pump
- Oil mist separator
- OFC (chemical oil filter), OFM (mechanical oil filter)
- Gas-ballast valve kit
- Operations monitoring unit
- SAS dust separator, KAS condensate separator
- Feet options: height-adjustable machine foot, castor wheels, floor mounting
Tabulated specifications for twelve model variants: booster/backing pump combination, pumping speed at 1 hPa (50/60 Hz), ultimate pressure with and without gas ballast, max. power consumption, input voltage, weight and gas inlet/outlet flanges.
- Pumping speeds range from 200/247 m³/h (WVD 0220, 50/60 Hz) up to 1646/2006 m³/h (WVD 1800, 50/60 Hz)
- Ultimate pressures range from 1.7·10⁻³ hPa (WVD 0245) down to 7.2·10⁻⁴ hPa (WVD 1800)
- All models: 400 V AC ±10 % at 50 Hz or 460 V AC ±10 % at 60 Hz
- Max. power consumption: 1.15 kW (0220/0235/0245/WS 0245) to 5.65 kW (WVD 1800)
- Gas inlets DN 100 or DN 160 ISO-F; outlets DN 40 ISO-KF to DN 100 ISO-F depending on model
- Weights from 218 kg (WVD 0220) to 1025 kg (WVD 1800)
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| COMBI WVD 1800 delivers the highest pumping speed of the series: 1646 m³/h at 50 Hz and 2006 m³/h at 60 Hz (at 1 hPa), using PANDA WV 2200 A + DuoVane 300. p.2 ↗ | For large-volume fast pump-down applications, this is the series' maximum-capacity single-booster option; plan handling for its 1025 kg weight. | COMBI WVD 1800 |
| Ultimate pressures span 7.2·10⁻⁴ hPa (WVD 1800) to 1.7·10⁻³ hPa (WVD 0245); with gas-ballast valve open they rise to 9.5·10⁻⁴ – 2·10⁻³ hPa. p.2 ↗ | Gas-ballast operation costs roughly 10–30 % in ultimate pressure; decide on gas ballast based on condensate/vapor load, not baseline spec. | all COMBI WVD/WS models |
| All models operate on 400 V AC ±10 %, 50 Hz or 460 V AC ±10 %, 60 Hz. p.2 ↗ | Single supply spec covers both 50 Hz (EU) and 60 Hz (US) sites; verify local voltage stays within ±10 % of 400/460 V. | all models |
| Max. power consumption: 1.15 kW (0220/0235/0245), 2.45 kW (0400/0440/0470/WS 0440), 4.87 kW (0900/0950/WS 0900), 5.65 kW (1800). p.2 ↗ | Size supply cabling and protection for the worst-case rating of the chosen variant; the WS 0245 WV2D stays at 1.15 kW despite twin backing pumps. | per model as listed |
| Gas inlet/outlet connections: inlet DN 100 ISO-F on most models, DN 160 ISO-F on WVD 0900/0950/1800; outlets DN 40 ISO-KF up to DN 100 ISO-F. p.2 ↗ | Matching downstream flange hardware must be specified per variant; the WS 0900 WV2D combines a DN 160 inlet with only a DN 40 ISO-KF outlet. | per model as listed |
| The 60 Hz versions give roughly 20–25 % higher pumping speed than 50 Hz (e.g. WVD 0950: 916 vs 1105 m³/h). p.2 ↗ | Performance figures must be selected per line frequency; do not use 50 Hz data for 60 Hz sites. | all models |
| Weights: 218 kg (WVD 0220), 270 kg (0235), 575 kg (0245), 240 kg (0400), 550 kg (0440), 720 kg (0470), 650 kg (0900), 900 kg (0950), 1025 kg (1800), 450 kg (WS 0245/0440), 570 kg (WS 0900). p.2 ↗ | Floor loading and lifting equipment must be selected for the heaviest variant on site; foot options (height-adjustable, castors, floor mounting) affect installation. | per model as listed |
| WS variants (COMBI WS 0245/0440/0900 WV2D) use two DuoVane 70 backing pumps paired with a single booster (WV 0250 C / WV 0500 C / WV 1200 A). p.2 ↗ | Twin backing-pump redundancy/parallel capacity differs from WVD single-pump variants; service planning must account for two backing pumps. | COMBI WS 0245/0440/0900 WV2D |
| Lowest ultimate pressure in the two-stage family is 8.2·10⁻⁴ hPa for COMBI WS 0900 WV2D (9.7·10⁻⁴ hPa with gas ballast). p.2 ↗ | The twin-DuoVane-70 configuration approaches the performance of the much heavier WVD 0900 (9.2·10⁻⁴ hPa) at lower weight (570 vs 650 kg). | COMBI WS 0900 WV2D |
| Booster/backing-pump pairings: WV 0250 C with DuoVane 36/70/135; WV 0500 C with DuoVane 70/135/300; WV 1200 A with DuoVane 135/300; WV 2200 A with DuoVane 300. p.2 ↗ | Defines valid upgrade paths: e.g. a WV 0500 C can be paired with any of three backing pumps, enabling capacity scaling within the same booster. | all models |
| Optional gas-ballast valve kit, OFC chemical and OFM mechanical oil filters, SAS dust separator and KAS condensate separator are offered. p.1 ↗ | For humid or dusty processes, add gas ballast plus condensate/dust separation to protect the oil-lubricated rotary vane stage; select OFC vs OFM per contaminant type (chemical vs particulate). | all models (options) |
| An operations monitoring unit and a dedicated control unit for booster and backing pump are available as options. p.1 ↗ | Coordinate booster/backing pump start-up sequencing and fault monitoring externally if these options are not fitted. | all models (options) |
| COMBI WVD 0400 (WV 0500 C + DuoVane 70) weighs only 240 kg yet reaches 426/512 m³/h and 1.2·10⁻³ hPa ultimate pressure. p.2 ↗ | Best pumping-speed-to-weight ratio option when installation footprint or handling capacity is limited. | COMBI WVD 0400 |