Engineering Digest Document Viewer Related Models

Calibration system Basic — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum 'Calibration system Basic' – a standardized, manually operated vacuum calibration system compliant with ISO/TS 3567. Variants/options include reference gauges (CMR or CCT type, DakkS-certified), OmniControl, TPG 366 indicator/controller for 6 gauges, various connection flanges, and customer-specific flange/pump configurations or a larger recipient on request.

Section-by-Section Technical Breakdown

pp. 1
Overview and Features

The Calibration system Basic is a standardized calibration system designed for user-friendly manual operation with an integrated control unit. It complies with the requirements of ISO/TS 3567 and can be adapted via individual flange connections and DakkS-certified reference gauges.

  • Standardized, user-friendly calibration system
  • Operated by hand and via integrated control unit (manual actuator)
  • Compliant with ISO/TS 3567
  • Individual flange connections to fit customer requirements
  • DakkS-certified reference gauges available
pp. 1
Accessories, Spare Parts and Options

A wide range of accessories and options is available for the calibration system, including reference gauges and control/indicator units. Individual configurations can be requested from the manufacturer.

  • Wide range of spare parts
  • Reference gauges (CMR or CCT type)
  • OmniControl
  • TPG 366 indicator and controller for 6 gauges
  • Various connection flanges
  • Individual flange and/or pump configurations on request
  • Larger recipient on request
pp. 2
Technical Data and Dimensional Drawing

The system achieves an ultimate pressure below 1·10⁻⁷ hPa and covers a measurement range from 1·10⁻⁴ to 1·10³ hPa. It is a manually actuated stainless steel unit weighing approx. 22.1 kg with a defined set of ISO-KF connection flanges and 115/230 V AC supply.

  • Ultimate pressure: < 1·10⁻⁷ hPa (mbar)
  • Measurement range: 1·10⁻⁴ – 1·10³ hPa (mbar)
  • Pumping speed backing pump at 50 Hz: 0.9 m³/h
  • Pumping speed for N₂: 67 l/s
  • Input voltages: 115/230 V AC (50/60 Hz)
  • Power consumption: 230 VA
  • Actuator / mode of operation: Manual
  • Cable length: 3 m
  • Material: Stainless steel, glass bead blasted
  • Precision: depending on used reference gauges
  • Weight: approx. 22.1 kg
  • Connecting flange (in): DN 16 ISO-KF
  • Connection for gauge: 2x DN 40 ISO-KF, 3x DN 16 ISO-KF, 2x DN 25 ISO-KF / 6x DN 40 ISO-KF
  • Gas inlet: DN 16 ISO-KF
  • Dimensional drawing provided on page 2

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ultimate pressure of the calibration system is < 1·10⁻⁷ hPa (mbar). p.2 ↗ Sufficient vacuum base pressure for calibrating gauges down to the 1·10⁻⁴ hPa lower measurement limit. Calibration system Basic (whole system)
Measurement range is 1·10⁻⁴ to 1·10³ hPa (mbar). p.2 ↗ Defines the pressure window in which gauges can be calibrated; reference gauges must cover this range. Calibration system Basic
Pumping speed for N₂ is 67 l/s. p.2 ↗ Sets pumpdown time constants when evacuating recipients; relevant for cycle-time planning. Calibration system Basic
Backing pump pumping speed at 50 Hz is 0.9 m³/h. p.2 ↗ Fore-vacuum capacity is fixed; verify suitability if larger recipients are requested. Calibration system Basic
Input voltages are 115/230 V AC at 50/60 Hz with 230 VA power consumption. p.2 ↗ Operable on both US and European mains supplies without transformers; dimension supply circuit for 230 VA. Calibration system Basic
Actuator and mode of operation are manual, with a 3 m cable length. p.2 ↗ No automated actuation in the Basic version; consider OmniControl option if automation is required. Calibration system Basic
Housing material is stainless steel, glass bead blasted, weight approx. 22.1 kg. p.2 ↗ Hydrocarbon-free clean vacuum-compatible construction; ~22 kg handling/mounting load must be supported. Calibration system Basic
Gauge connections are 2x DN 40 ISO-KF, 3x DN 16 ISO-KF, 2x DN 25 ISO-KF, or alternatively 6x DN 40 ISO-KF. p.2 ↗ Up to six gauges can be mounted depending on flange configuration, matching the TPG 366 6-gauge controller option. Calibration system Basic (variant-dependent)
Gas inlet and inlet connecting flange are both DN 16 ISO-KF. p.2 ↗ Gas admission hardware must use small-KF (DN 16 ISO-KF) fittings; plan leak/valve interfaces accordingly. Calibration system Basic
Calibration precision depends on the reference gauges used (CMR or CCT type, DakkS-certified). p.1 ↗ System accuracy is not intrinsic; select DakkS-certified reference gauges to meet metrological requirements. Calibration system Basic with CMR/CCT reference gauges
System complies with ISO/TS 3567 requirements. p.1 ↗ Vacuum gauge calibrations performed on this system can be claimed as ISO/TS 3567-conformant. Calibration system Basic
Individual flange and/or pump configurations and a larger recipient are available on request. p.1 ↗ Non-standard gauge counts or volumes can be ordered as custom configurations rather than modifying the standard unit. Calibration system Basic (options)