COBRA DS 8161 F — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Single model datasheet: Pfeiffer Vacuum COBRA DS 8161 F, a dry screw vacuum pump with an integrated vacuum booster (canned motor, indirect water cooling), aimed at semiconductor processes (CVD, RTP, ALD). No variants or ordering codes are given.
Section-by-Section Technical Breakdown
The COBRA DS 8161 F is a dry screw vacuum pump combining a screw backing pump with an integrated vacuum booster. It targets high-performance applications such as chemical vapor deposition, rapid thermal processing and atomic layer deposition. Benefits cited are low cost of ownership, long service intervals, high hydrogen throughput and a compact, fit-in-place design with a directly mounted canned motor.
- Advanced screw design with excellent running qualities
- Integrated vacuum booster on the screw pump
- Suited to CVD, rapid thermal processing, ALD
- Efficient indirect water cooling; high hydrogen throughput
- Minimal maintenance, long service intervals, high uptime
- Compact fit-in-place design with directly mounted canned motor
The datasheet lists full performance data: 6000 m³/h nominal pumping speed (air at 20°C, ±10% tolerance), 0.001 hPa ultimate pressure, and two 15 kW motors (backing pump 3600 min⁻¹, booster 5400 min⁻¹). Utilities and installation data include water consumption, nitrogen purge range, weight, dimensions and flange sizes.
- Nominal pumping speed: 6000 m³/h (air at 20°C, tolerance ±10%)
- Ultimate pressure: 0.001 hPa (mbar)
- Nominal motor rating: 15 kW backing pump; 15 kW vacuum booster
- Power consumption at ultimate pressure / idle mode: 12.5 / 10 kW
- Motor speeds: 3600 min⁻¹ (backing pump), 5400 min⁻¹ (booster)
- Sound pressure level (ISO 2151, KpA = 3 dB): < 75 dB(A)
- Water consumption: min. 15 l/min
- Nitrogen consumption: 0 – 200 l/min
- Weight: approx. 1500 kg
- Dimensions (L x W x H): 1441 x 627 x 1100 mm
- Gas inlet / outlet: DN 200 / DN 63
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Nominal pumping speed is 6000 m³/h with a tolerance of ±10% (air at 20°C) p.2 ↗ | Size upstream conductance and process throughput with up to 10% speed deviation in mind | COBRA DS 8161 F |
| Ultimate pressure is 0.001 hPa (mbar) p.2 ↗ | Suitable for high-vacuum semiconductor processes like ALD and CVD without a separate backing train | COBRA DS 8161 F |
| Two 15 kW motors are required: backing pump (3600 min⁻¹) and integrated vacuum booster (5400 min⁻¹) p.2 ↗ | Electrical supply must support up to 30 kW nominal connected motor load plus inrush; verify cable and breaker sizing accordingly | COBRA DS 8161 F |
| Power consumption is 12.5 kW at ultimate pressure and 10 kW in idle mode p.2 ↗ | Actual energy cost is well below nominal motor rating; use these values for operating cost and heat-load calculations | COBRA DS 8161 F |
| Cooling water consumption is at least 15 l/min (indirect water cooling) p.2 ↗ | Cooling circuit must guarantee a continuous minimum flow of 15 l/min; plan chiller/plant-water capacity accordingly | COBRA DS 8161 F |
| Nitrogen consumption ranges from 0 to 200 l/min p.2 ↗ | Purge/inerting gas supply must be adjustable up to 200 l/min for process dilution or condensate protection | COBRA DS 8161 F |
| Sound pressure level is < 75 dB(A) per ISO 2151 (KpA = 3 dB) p.2 ↗ | Typically installable without special acoustic enclosure in most industrial noise regulations | COBRA DS 8161 F |
| Unit weight is approx. 1500 kg with footprint 1441 x 627 x 1100 mm (L x W x H) p.2 ↗ | Floor/loading capacity must support 1500 kg on a narrow 0.63 m footprint; lifting gear rated accordingly | COBRA DS 8161 F |
| Gas inlet is DN 200 and outlet DN 63 p.2 ↗ | Vacuum line and exhaust pipework must match DN 200 intake (e.g., ISO/CF-K flanges) and DN 63 exhaust; avoid undersized inlet that would reduce effective speed | COBRA DS 8161 F |
| Motor is a directly mounted canned motor (dry-running, no shaft seals/lubricant in process volume) p.1 ↗ | No oil contamination of process gases; simplifies maintenance but requires attention to cooling water for the canned motor | COBRA DS 8161 F |
| Pump uses an integrated vacuum booster with booster motor speed of 5400 min⁻¹ p.1 ↗ | High compression at low pressures; do not operate against atmospheric exhaust without proper exhaust-side conditions per normal backing-pump practice | COBRA DS 8161 F |
| High hydrogen throughput is claimed p.1 ↗ | Suitable for hydrogen-bearing semiconductor process gases where conventional dry pumps may struggle | COBRA DS 8161 F |