Induztr
Engineering Digest Document Viewer Related Models

HiLobe 1002 — product leaflet

Technical Reference Summary

Covered Models & Document Scope

Pfeiffer Vacuum HiLobe 1002 and HiLobe 1302 vacuum boosters (Roots-type). Same envelope and flanges, differing mainly in rotational speed range (1002: 1500–1600 rpm; 1302: 1500–7500 rpm) and max differential pressure. Options/accessories listed include Profinet converter, barrier gas kit (plastic/stainless steel), gear chamber evacuation, flushing device, temperature/pressure monitoring, extension cable package, OmniControl, horizontal version, drive electronics variants (box, switch-cabinet mounting plate, none), and cooling options (convection, active-air, water).

Section-by-Section Technical Breakdown

pp. 1
Product Features, Accessories and Options

Highlights condition monitoring via integrated sensors, IE5 hermetically sealed canned-motor design without shaft seals, variable speed drive, and extended maintenance intervals. Lists available accessories and drive/cooling options.

  • Integrated sensor condition monitoring for high up-time
  • IE5 hermetically sealed synchronous motor, canned motor design, no shaft seals
  • Variable speed drive and optimized rotor geometries
  • Options: Profinet converter, barrier gas kit (plastic or stainless steel), gear chamber evacuation, flushing device (spray lance)
  • Temperature and pressure monitoring (inlet and exhaust side), extension cable package, OmniControl, horizontal version
  • Drive electronics: box version, mounting plate for switch cabinet integration, or without drive electronics
  • Cooling options: convection, active-air, water cooling
pp. 2
Technical Data: Pumping Speed, Pressure Limits and Electrical Data

Pumping speed curves at 50/60 Hz plus core performance and electrical specifications. Both models share nominal pumping speed 260–1050 m³/h, DN100 flanges, and RC 5500 electronic drive unit; they differ in speed range and allowable differential pressure.

  • Nominal pumping speed 260–1050 m³/h (both models)
  • Rotational speed: HiLobe 1002 1500–1600 rpm; HiLobe 1302 1500–7500 rpm
  • Max differential pressure at max speed: 21 hPa (1002), 13 hPa (1302); at min speed 41 hPa (both)
  • Flanges: DN 100 ISO-F | DN 100 PN 16 (inlet and exhaust, both models)
  • Input voltage 380–480 V AC (±10%), 50/60 Hz; three-phase motor with PTC protection
  • Rated power at full speed: 2 kW (1002), 2.5 kW (1302)
  • Electronic drive unit RC 5500; recommended mains fuse 16 A
  • I/O interfaces: PV.can and RS485
pp. 3
Physical Data and Operating Conditions

Acoustic, environmental, fluid, and mechanical specifications. Identical for both models: D2 operating fluid, IP54/type 12 enclosure, identical dimensions and weight.

  • Sound pressure level (EN ISO 2151) at 1 hPa inlet pressure: 56 dB(A) (1002), 60 dB(A) (1302)
  • Operating fluid D2, filling 0.65 l
  • Protection degree IP54; type 12
  • Integral leak rate 1E-06 Pa·m³/s
  • Dimensions 678 x 282 x 240 mm (L x W x H); weight approx. 105 kg
  • Ambient temperature 5–40 °C; shipping temperature -10–40 °C

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
HiLobe 1002 runs at 1500–1600 rpm; HiLobe 1302 at 1500–7500 rpm. p.2 ↗ The 1302 offers far higher speed for throughput; the 1002 is speed-limited for lower speed/longer life applications. HiLobe 1002 vs 1302
Max differential pressure at max rotational speed: 21 hPa (1002) and 13 hPa (1302). p.2 ↗ Downstream backing pump sizing must keep differential pressure below these limits at full speed, especially for the 1302. Both models (values differ per model)
Max differential pressure at minimum rotational speed is 41 hPa for both models. p.2 ↗ Speed reduction can be used to tolerate higher differential pressures during startup/crossover. Both models
Nominal pumping speed 260–1050 m³/h for both models. p.2 ↗ Both cover the same speed range for pump-down design; actual speed depends on inlet pressure per the 50/60 Hz curves. Both models
Inlet/exhaust flanges are DN 100 ISO-F or DN 100 PN 16. p.2 ↗ Choose ISO-F for vacuum-grade clamped connections or PN16 for pressure-rated flanged piping; both ports identical. Both models
Supply voltage 380–480 V AC ±10%, 50/60 Hz, three-phase motor with PTC protection. p.2 ↗ Requires a suitable three-phase supply within tolerance; PTC trip must be wired into the drive/control for motor protection. Both models
Rated power 2 kW (1002) / 2.5 kW (1302); recommended mains fuse 16 A. p.2 ↗ Size supply and breaker per 16 A fuse recommendation; drive electronics is the RC 5500. Both models
I/O interfaces are PV.can and RS485; Profinet converter available as option. p.1 ↗ For Profinet integration an external converter accessory must be ordered; native control via PV.can/RS485. Both models
Hermetically sealed IE5 synchronous canned motor with no shaft seals. p.1 ↗ Eliminates shaft-seal leaks in the vacuum envelope, supporting the 1E-06 Pa·m³/s integral leak rate; no shaft seal maintenance. Whole series
Integral leak rate 1E-06 Pa·m³/s. p.3 ↗ Suitable for high-vacuum systems; validate system leak-up against this pump contribution. Both models
Operating fluid D2, filling volume 0.65 l. p.3 ↗ Stock D2 operating fluid and plan lubricant changes around 0.65 l fill per gearbox. Both models
Ambient temperature 5–40 °C; shipping/storage -10–40 °C. p.2 ↗ Ensure installation environment stays within 5–40 °C; freeze protection needed below -10 °C during transport. Both models
Protection degree IP54, type 12; default cooling is convection (active-air and water cooling optional). p.1 ↗ IP54 enclosure allows industrial panel-adjacent installation; for high heat loads select active-air or water cooling option. Both models
Sound pressure level at 1 hPa inlet pressure: 56 dB(A) (1002) / 60 dB(A) (1302) per EN ISO 2151. p.3 ↗ Low noise; both acceptable in laboratory/industrial spaces without special acoustic measures. Both models
Dimensions 678 x 282 x 240 mm, weight approx. 105 kg (both models). p.3 ↗ Compact footprint but ~105 kg requires lifting equipment or frame handling for installation. Both models
Accessories include barrier gas kit (plastic or stainless steel), gear chamber evacuation, flushing device (spray lance), and temperature/pressure monitoring on inlet and exhaust. p.1 ↗ Barrier gas and monitoring options should be ordered for processes with condensable media or requiring process diagnostics. Whole series