DuoVane 12 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum DuoVane 6, DuoVane 12, DuoVane 18, DuoVane 22 two-stage oil-lubricated rotary vane vacuum pumps; each available with single-phase or three-phase motor; DuoVane 18 and 22 also available as C-Version (corrosive gas version). Accessories and maintenance kits (vane spring kit, sight glass kit, valve and spring kit, seal kit, shaft seal ring, diaphragm kit, gas-ballast valve kit, overhaul kit, oil mist separator, dust separator, sorption trap, cold trap, vacuum pump oil) are listed as options.
Section-by-Section Technical Breakdown
The DuoVane 6-22 series comprises two-stage oil-lubricated rotary vane vacuum pumps in four sizes (DuoVane 6, 12, 18, 22). The pumps feature the best pumping-speed-to-size ratio in their class with fast pump-down from atmospheric pressure, lowest power consumption in the performance class, and are nearly maintenance-free. Reliability is supported by an integrated gas-ballast valve and an optimized vacuum safety valve.
- Two-stage oil-lubricated rotary vane principle
- Best pumping-speed-to-size-ratio in its class, fast pump-down from atmospheric pressure
- Lowest power consumption in its performance class, nearly maintenance-free
- Integrated gas-ballast valve and optimized vacuum safety valve
- Available accessories: vane spring kit, sight glass kit, valve and spring kit, seal kit, shaft seal ring, diaphragm kit, gas-ballast valve kit, overhaul kit, oil mist separator, dust separator, sorption trap, cold trap, C-Version (corrosive gas version), single-phase or three-phase motor, vacuum pump oil
This section gives the full performance and mechanical data for the four pump sizes at 50/60 Hz: nominal pumping speed, ultimate pressure (gas-ballast valve open/closed), motor data, noise level, oil capacity, weight, dimensions and flange connections. A dimensional drawing and a pumping-speed curve (air at 20°C, tolerance ±10%) are shown. The corrosive gas (C) version is only offered for DuoVane 18 and 22.
- Nominal pumping speed: DuoVane 6: 5.5/6.5 m³/h; DuoVane 12: 9.5/11.8 m³/h; DuoVane 18: 14/16.9 m³/h; DuoVane 22: 19.5/22.5 m³/h (50/60 Hz)
- Ultimate pressure: 3·10⁻³ hPa (mbar) with gas-ballast valve closed; 1·10⁻² hPa (mbar) with gas-ballast valve open (all models)
- Motor: single-phase or three-phase; nominal rating 0.45/0.55 kW (DuoVane 6/12) and 0.55/0.66 kW (DuoVane 18/22) at 50/60 Hz; nominal speed 1500/1800 min⁻¹
- Noise level (50 Hz): 50 dB(A) for DuoVane 6/12, 52 dB(A) for DuoVane 18/22
- Oil capacity: 1.1 l (DuoVane 6), 1.2 l (DuoVane 12), 1.3 l (DuoVane 18/22)
- Weight approx.: 25.5 kg (DuoVane 6), 27.5 kg (DuoVane 12), 31 kg (DuoVane 18), 32 kg (DuoVane 22)
- Dimensions L x W x H: 413x164x237 mm (DuoVane 6), 428x164x237 mm (DuoVane 12), 465x164x237 mm (DuoVane 18), 483x164x237 mm (DuoVane 22)
- Gas inlet/outlet: DN 25 ISO-KF / DN 25 ISO-KF on all models
- Corrosive gas version available only for DuoVane 18 and DuoVane 22
- Pumping speed curves measured with air at 20°C, tolerance ±10%
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Ultimate pressure is 3·10⁻³ hPa (mbar) with the gas-ballast valve closed and 1·10⁻² hPa (mbar) with the valve open, identical across all four models. p.2 ↗ | For process applications needing condensate purge (gas ballast open), size the system for a one order-of-magnitude worse ultimate pressure. | whole series |
| Nominal pumping speeds at 50 Hz are 5.5, 9.5, 14 and 19.5 m³/h; at 60 Hz they rise to 6.5, 11.8, 16.9 and 22.5 m³/h. p.2 ↗ | On 60 Hz supplies, expect roughly 18-21% higher pumping speed; pump sizing should reference the correct frequency column. | whole series (per model) |
| Pumping speed curves apply to air at 20°C with a tolerance of ±10%. p.2 ↗ | Allow ±10% margin when calculating pump-down times; gases other than air at other temperatures will deviate further. | whole series |
| Nominal motor rating is 0.45/0.55 kW (50/60 Hz) for DuoVane 6 and 12, and 0.55/0.66 kW for DuoVane 18 and 22. p.2 ↗ | Electrical supply and breaker sizing can use a maximum of 0.66 kW for all four models. | whole series (per model) |
| All models run at nominal motor speed of 1500 min⁻¹ (50 Hz) / 1800 min⁻¹ (60 Hz). p.2 ↗ | Pumps are standard 2-pole machines; VFD operation beyond these speeds should be avoided. | whole series |
| Every model is available with either a single-phase or a three-phase motor. p.2 ↗ | Lab installations without three-phase supply can still use the largest DuoVane 22. | whole series |
| Noise level at 50 Hz is 50 dB(A) for DuoVane 6/12 and 52 dB(A) for DuoVane 18/22. p.2 ↗ | Suitable for bench/lab placement without special acoustic enclosures. | whole series (per model) |
| Oil capacities are 1.1 l (DuoVane 6), 1.2 l (DuoVane 12) and 1.3 l (DuoVane 18/22). p.2 ↗ | Spec the correct oil refill quantity for maintenance intervals; only ~1.3 l of Pfeiffer vacuum pump oil needed at most. | whole series (per model) |
| All models use DN 25 ISO-KF for both gas inlet and outlet. p.2 ↗ | A single standard KF25 fitting/ clamp/gasket set covers installation of any pump in the series. | whole series |
| Footprint is uniform 164 mm wide × 237 mm high; lengths are 413, 428, 465 and 483 mm for DuoVane 6, 12, 18 and 22 respectively. p.2 ↗ | Mounting plates/racks can share a common height and width envelope; only length varies (max 483 mm). | whole series (per model) |
| Weights are approx. 25.5, 27.5, 31 and 32 kg for DuoVane 6, 12, 18 and 22. p.2 ↗ | Pumps are manually liftable by one or two persons; bench structures must support ≥32 kg for the largest model. | whole series (per model) |
| The corrosive gas C-Version is only available for DuoVane 18 and DuoVane 22 (marked 'x' in the data table). p.2 ↗ | Applications with corrosive media at lower speeds must be handled by the 18 or 22; DuoVane 6/12 cannot be specified in corrosive version. | DuoVane 18 and DuoVane 22 only |
| An integrated gas-ballast valve and an optimized vacuum safety valve are standard on all pumps. p.1 ↗ | No external ballast dosing or non-return valve needed for vapor handling and protection against backflow into the evacuated volume. | whole series |
| Maintenance kits offered include vane spring kit, valve and spring kit, seal kit, shaft seal ring, diaphragm kit and overhaul kit, plus oil mist separator, dust separator, sorption trap and cold trap accessories. p.1 ↗ | Plan preventive maintenance as seal/valve/vane-spring replacements via kits; sorption or cold traps should be specified upstream for aggressive/dusty/condensable media on non-C versions. | whole series |