Agilent Technologies 1290 Infinity III Bio LC | Biocompatible UHPLC system
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1290 Infinity III Bio LC | Biocompatible UHPLC system

Agilent Technologies 1290 Infinity III Bio LC | Biocompatible UHPLC system — Liquid chromatography.

The 1290 Infinity III Bio LC is a biocompatible UHPLC system configured for biopharmaceutical analysis, with a 300–3,200 m/z mass range and 12 L/min gas flow at 270 °C. It is distinguished within the Bio LC series by its bio-inert flow path and suitability for oligonucleotide and peptide workflows. It serves as the chromatographic front end for LC/MS quantitation and characterization of biologics.

Agilent Technologies Bio LC Solutions Series — Model Comparison & Selection

Model Flow rate, liter/minuteMass rangeMax pressure, megapascalPumping speed, m³/hWavelength rangeSample volume, milliliter
1290 Infinity III Bio LC | Biocompatible UHPLC system Current —300...3,200———0.005
1260 Infinity Amino Acid Analysis System ——————
1260 Infinity III Bio-Inert LC System 0.01—606×10⁻⁴190...950—

Full specifications

Core Performance & Functional Specifications
Gas Flow 12 L/min
Gradient Time 17 min
Sample volume 5 μL
Sheath Gas Flow 12 L/min
LLOQ mfr 0.2 ng/mL
Linear range upper limit mfr 1000 ng/mL
Sensitivity improvement vs organic solvent precipitation mfr five times times
Ion mode mfr Positive Positive
Tirzepatide precursor ion mfr 1204.4 m/z
Tirzepatide product ion mfr 396.2 m/z
Tirzepatide collision energy mfr 26
Tirzepatide second product ion mfr 136.1 m/z
Tirzepatide second collision energy mfr 42
Semaglutide precursor ion mfr 1029.4 m/z
Semaglutide product ion mfr 1238.1 m/z
Semaglutide collision energy mfr 30
Low QC concentration mfr 0.5 ng/mL
Mid QC concentration mfr 10.00 ng/mL
High QC concentration mfr 800 ng/mL
Interday % CV at LLOQ mfr 6.7
Interday % CV at Low QC mfr 6.3
Interday % CV at Mid QC mfr 8.8
Interday % CV at High QC mfr 5.5
Needle wash mfr 3
RNase T1 amount mfr 0.5 units
CNP digest amount mfr 2 μg
Solvent A composition mfr 15 water
Sample concentration mfr 1 mg/mL
Heat stress incubation time points mfr 4 hours
Oxidative stress H2O2 concentration mfr 0.30
Oxidative stress duration mfr 2 hours
Source mfr Dual AJS AJS
Nebulizer mfr 35 psi
Tune Mode mfr Extended Dynamic Range Range
Acquisition Mode mfr MS Scan Scan
MS Scan Range mfr 400...3,000
Software version mfr 1.5
Match Tolerance mfr 10 ppm
Dimensions, Weight & Mechanical Design
Mass range 300...3,200
Electrical, Power & Drive Specifications
Skimmer mfr 65 V
Materials, Media & Process Compatibility
Starting material volume mfr 100 μL
Operating Conditions, Environment & Protection
Gas Temperature 270 °C
Sample Storage Temperature 80 °C

Description

Construction and positioning

Behavior and workflow context

Installation and operation

Integration & Operating Notes

Process Limits
Bio-inert flow path required for metal-sensitive analytes

The system is specified as biocompatible; methods involving oligonucleotides or peptides that adsorb to stainless steel must use the bio-inert configuration throughout, including column hardware, to avoid loss and peak distortion.

Application note, CRISPR-Cas9 HILIC analysis
Control & I/O
LC/MS control and quantitation rely on MassHunter software

The semaglutide quantitation workflow uses MassHunter software to control the LC and MS and to process MRM data; integration planning must include the software license and PC configuration, which are not part of the base instrument delivery.

Application note, automated LC/MS GLP-1 analog semaglutide

Selection & Integration Q&A

When should I choose the 1290 Infinity III Bio LC instead of the 1260 Infinity III Bio-Inert LC or the 1260 Infinity III Prime Bio LC?

Choose the 1290 Infinity III Bio LC when the method needs the higher-pressure 1290 platform for small-particle bio columns; the 1260 Infinity III Bio-Inert LC is rated 600 bar and 10 mL/min with 190–950 nm detection, and the Prime Bio LC covers other 1260 configurations. The 1290 is the choice for UHPLC-resolution oligonucleotide and peptide work.

What adjacent instrumentation and software are required to run the semaglutide quantitation workflow on this system?

The workflow pairs the bio LC with an Agilent 6495D triple quadrupole LC/MS, an AssayMAP Bravo with RP-S cartridges for sample prep, and MassHunter software for control and data processing. MRM transitions for semaglutide (1029.4 → 1238.1, CE 30) and tirzepatide (1204.4 → 396.2, CE 26) are programmed in the method.

What maintenance and consumables are needed beyond the base instrument delivery?

The validated method uses a needle wash of 3 cycles, requiring wash solvent supply and a functioning needle-wash pump; RP-S cartridges for the AssayMAP Bravo and LC columns (e.g., Ultra-Inert hardware for oligonucleotide HILIC) are separate consumables. No service interval is given in the supplied digests; follow the system manual schedule.