Agilent Technologies 1290 Infinity III LC
Agilent Technologies 1290 Infinity III LC — Liquid chromatography with Pumping speed 6×10⁻⁵ m³/h.
The 1290 Infinity II high-throughput system is a UHPLC configuration built around a 1290 Infinity II pump and autosampler, distinguished within the 1260 Infinity II GPC/SEC series by its 800 bar Quick Turn fitting pressure limit and sub-3 µm column compatibility. It is intended for fast, high-resolution separations in GPC/SEC workflows where sample throughput and method speed are the primary constraints.
Full specifications
| Pumping speed | 1 mL/minute |
| Column Particle Size | 2.7 µm |
| Column temperature | 55 °C |
| Drying Gas Flow | 15 L/min |
| Filter Membrane Diameter | 47 mm |
| Filter Membrane Pore Size | 0.2 μm |
| Flow Rate (1220 Infinity Ii Lc) | 10 mL/minute |
| Flow Rate (1290 Infinity Iii Lc) | 5 mL/minute |
| Gas Flow | 9 L/min |
| Maximum operating pressure | 1300 bar |
| Ptfe Frits Per Pm Kit | 5 pk |
| Sample volume | 10 µL |
| Scan speed | 4 spectra/sec |
| Sheath Gas Flow | 11 L/min |
| Solvent Bottle Volume | 1 L |
| Solvent Filtration Assembly Flask Volume | 1 L |
| Solvent Filtration Assembly Funnel Volume | 250 mL |
| Solvent Inlet Filter Pore Size | 10 μm |
| Well-plate Closing Mat Quantity | 50 pk |
| Well-plate Volume | 0.5 mL |
| Quick Connect heat exchanger flow rate mfr | 2.5 mL/min |
| Capillary dimensions mfr | 0.12 mm |
| Preventive maintenance cost reduction mfr | 30 |
| Pump seals per PM kit mfr | 4 |
| Seal cap assembly sets per PM kit mfr | 2 |
| Gold seals for outlet valve per PM kit mfr | 2 |
| Seal washes per PM kit mfr | 4 |
| Solvent bottles per convenience kit mfr | 3 amber |
| Analysis time (ACR configuration) mfr | 5.1 min |
| Analysis time reduction with ACR mfr | 30 |
| Number of analytes mfr | 125 |
| Eluent pump flow rate mfr | 0.35 mL/min |
| Regeneration pump flow rate mfr | 0.5 mL/min |
| Needle wash mfr | 50 O |
| Nebulizer pressure mfr | 60 psig |
| Column dimensions mfr | 2.1 mm |
| Gradient mfr | 5 equilibration |
| Binary Pump mfr | High-Speed Pump* |
| Quaternary Pump mfr | Flexible Pump** |
| Solvent Preparation mfr | 1260 Degasser |
| Solvent Delivery mfr | 1260 Pump |
| Valve Solutions mfr | InfinityLab Quick Change Valves Valves |
| Maximum operating pressure (1260 Infinity III Prime LC) mfr | 800 bar |
| Maximum operating pressure (1260 Infinity III LC) mfr | 400 bar |
| Maximum operating pressure (1220 Infinity II LC) mfr | 600 bar |
| Pressure at 2 mL/min (1290 High-Speed Pump) mfr | 1300 bar |
| Pressure at 5 mL/min (1290 High-Speed Pump) mfr | 800 bar |
| Pressure (1260 Infinity III Flexible Pump) mfr | 800 bar |
| Pressure (1260 Infinity III Binary Pump) mfr | 600 bar |
| Pressure (1260 Infinity III Quaternary Pump VL) mfr | 400 bar |
| Flow rate (1260 Infinity III Quaternary Pump VL) mfr | 10 ml/min |
| Sample capacity (1290 Infinity III Multisampler) mfr | 6144 samples |
| Carryover (1290 Infinity III Multisampler multiwash) mfr | 9 ppm |
| Wavelength range (1290 Infinity III DAD) mfr | 190...640 nm |
| Wavelength range (1260 Infinity III DAD WR) mfr | 190...950 nm |
| ELSD flow range (1290 Infinity III ELSD) mfr | 0.2...5 mL/min |
| RI measurement range (1290 Infinity III RID) mfr | 600 RIU |
| Quick Turn pressure (finger-tight) mfr | 600 bar |
| inline filter pore size (HPLC) mfr | 0.5 μm |
| high-flow heat exchanger volume mfr | 3.0 μL |
| low-dispersion heat exchanger volume mfr | 1.1 μL |
| high flow rate threshold mfr | 2.5 mL/min |
| Capillary Voltage | 3750 V |
| Mobile phase A mfr | 2 Acid |
| Mobile phase B mfr | 0.01 Acid |
| Mobile phase A (positive mode) mfr | 5 |
| Mobile phase B (positive mode) mfr | 0.1 ACN |
| Mobile phase A (negative mode) mfr | 0.1 water |
| Vcap mfr | 3500 V |
| Fragmentor mfr | 125 V |
| Quick Turn Fitting Pressure Limit | 800 bar |
| Solvent bottle thread mfr | 45 |
| Autosampler Temperature | 5 °C |
| Gas Temperature | 300 °C |
| Sheath Gas Temperature | 380 °C |
| Column thermostat range (1290 Infinity III Multicolumn thermostat) mfr | 20...110 °C |
| Column thermostat range (1260 Infinity III Multicolumn thermostat) mfr | 10...85 °C |
| Analysis time (standard configuration) mfr | 7.35 min |
Description
Construction and series positioning
- The 1290 Infinity II high-throughput system is the fastest configuration in the 1260 Infinity II GPC/SEC series; sibling models (1220 Infinity II LC, 1260 amino acid analysis, analytical-scale purification) trade speed for lower pressure or preparative scale.
- Quick Turn fittings rated to 800 bar define the hydraulic ceiling; columns with 2.7 µm particles are supported, enabling shorter analysis times than conventional GPC/SEC columns.
- The system is supplied as a complete LC workflow with solvent filtration (47 mm, 0.2 µm membranes), 1 L solvent bottles, and 10 µm solvent inlet filters.
Behavior under load and in different modes
- Standard configuration analysis time is 7.35 min; the Alternate Column Regeneration (ACR) configuration reduces this to 5.1 min, a 30% reduction, by regenerating one column while the other separates.
- The ACR method uses two Poroshell 120 EC-C18 columns (2.1 × 10 mm) and has been demonstrated for 125 analytes in urine on a 1290 Infinity II UHPLC coupled to a 6470 TQ mass spectrometer.
- Pumping speed is 1 mL/min; sample volume is 10 µL; column temperature is 55 °C; autosampler temperature is 5 °C.
Installation, connection and operation
- The system requires solvent filtration and degassing; PTFE frits (5 per PM kit) and solvent inlet filters (10 µm) protect the pump and column.
- Quick Connect heat exchanger flow rate is 2.5 mL/min; capillary dimensions are 0.17 mm.
- Preventive maintenance kits include 2 pump seals, 2 seal cap assembly sets, 2 gold seals for the outlet valve, and 4 seal washes; PM cost reduction is stated as 30%.
Integration & Operating Notes
The Quick Turn fitting pressure limit is 800 bar; operating above this risks fitting failure and leakage. Verify that column backpressure at the configured flow rate (1 mL/min) and mobile phase viscosity remains below this limit, especially at low temperatures or with high-viscosity solvents.
The system is specified with 2.7 µm column particles; using larger particles may reduce resolution, while smaller particles can raise backpressure beyond the 800 bar fitting limit. Select columns and flow rates together to stay within the pressure ceiling.
Preventive maintenance kits include 2 pump seals, 2 seal cap assembly sets, 2 gold seals for the outlet valve, and 4 seal washes. Schedule seal replacement according to the PM interval to avoid leaks and baseline noise; the kit is not included in base delivery.
Use 47 mm, 0.2 µm filter membranes and 10 µm solvent inlet filters to remove particulates; unfiltered mobile phases can clog frits and damage the pump. The filtration assembly includes a 1 L flask and 250 mL funnel.
Selection & Integration Q&A
Choose the 1290 high-throughput system when method speed and sub-3 µm column performance are critical: it supports 2.7 µm particles and 800 bar fittings, with analysis times of 7.35 min (standard) or 5.1 min (ACR). The 1220 Infinity II LC is a lower-pressure analytical system; the 1260 amino acid system is dedicated to amino acid analysis.
Use Quick Turn fittings rated to 800 bar and columns with 2.7 µm particles, such as Poroshell 120 EC-C18 (2.1 × 10 mm) for ACR. The system has been demonstrated with a 6470 TQ MS; ensure the column backpressure at 1 mL/min stays below 800 bar and that the 0.17 mm capillary connects properly.
Preventive maintenance kits (2 pump seals, 2 seal cap assembly sets, 2 gold seals, 4 seal washes), PTFE frits (5 pk), solvent inlet filters (10 µm), and filter membranes (47 mm, 0.2 µm) are not included in base delivery. Order them separately; PM cost reduction is stated as 30%.